Advertisement

Improvement Works to Existing Column Stumps by Fiber-Reinforced Polymer Strengthening System

  • Jin Ping Lu
  • Sook Fun Wong
Conference paper

Abstract

How to improve the durability of concrete structures has long been studied in many countries, especially in the island country of Singapore, where marine concrete structures are very common along coastal areas. The service life of marine concrete structure can be enhanced by different ways, such as the addition of admixtures and using high-grade concrete. Another effective method is by using the FRP system to strengthen the concrete structure. This study deals with improvement works carried out on the column stumps of existing concrete structures by adopting the fiber-reinforced polymer (FRP) strengthening system. Various standard test methods and computer modeling were conducted to examine the effectiveness of the FRP strengthening system using glass fiber composite. The results showed that the FRP wrapping for column stumps of 200 × 200 mm can increase the ultimate strength by an average of 124%.

References

  1. 1.
    Saadatmanesh, H., Ehsani, M. R., & Li, M. W. (1994). Strength and ductility of concrete columns externally reinforced with composites straps. ACI Structural Journal, 91(4), 434–447.Google Scholar
  2. 2.
    Mirmiran, A., et al. (1998). Effect of column parameters on FRP-confined concrete. ASCE Journal of Composites for Construction., 2(4), 175–185.CrossRefGoogle Scholar
  3. 3.
    Benzaid, T. C., Chikh, N. E., & Mesbah, H. (2008). Behaviour of square concrete columns confined with GFRP composite wrap. Journal of Civil Engineering and Management, 14(2), 115–120.CrossRefGoogle Scholar
  4. 4.
    Youssef, M. N., Feng, M. Q., & Mosallam, A. S. (2007). Stress-strain model for concrete confined by FRP composites. Composites Part B: Engineering, 38, 614–628.CrossRefGoogle Scholar
  5. 5.
    Rochette, P., & Labossière, P. (2000). Axial testing of rectangular column models confined with composites. ASCE Journal of Composites for Construction, 4(3), 129–136.CrossRefGoogle Scholar
  6. 6.
    Lam, L., & Teng, J. G. (2002). Strength models for fiber-reinforced plastic-confined concrete. Journal of Structure Engineer, 128(5), 612–623.CrossRefGoogle Scholar
  7. 7.
    Lu, J. P., Tan, K. H., & Zheng, D. (2015). Strengthening of column stump using glass fiber composite strengthening system. Advanced Materials Research: Polymers in Concrete Towards Innovation, Productivity and Sustainability in the Build Environment, 1129, 353–360.CrossRefGoogle Scholar

Copyright information

© Springer International Publishing AG, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Admaterials Technologies Pte LtdSingaporeSingapore
  2. 2.Temasek PolytechnicSingaporeSingapore