Advertisement

Finite Element Modeling of CFRP-Strengthened Low-Strength Concrete Short Columns

  • Khaled A. Alawi Al-Sodani
  • Muhammed K. Rahman
  • Mohammed A. Al-Osta
  • Ali A. H. Al-Gadhib
Conference paper

Abstract

Carbon fiber-reinforced polymer (CFRP) sheets and plates are now being extensively used as retrofitting/strengthening system, due to high strength, low weight, corrosion resistance, and ease and speed of application. Structures with very low-strength reinforced concrete columns, constructed during the early 1970s and 1980s, are rampant in many countries. These structures are prone to collapse during a seismic event. It is important to investigate if these low-strength concrete columns can be made safe by CFRP sheet strengthening. An experimental and numerical investigation conducted on short circular low-strength concrete column is presented. The results of this study showed that the confinement equations for concrete columns as per ACI and CSA codes give erroneous results for these columns. The CSA code equations require satisfaction of certain constrains, which are not applicable to such columns. Control specimen (unconfined specimens) results showed that both CSA and ACI equations overestimate the ultimate loads of low-strength RC columns by an order in magnitude. For CFRP-confined specimens, the ACI and CSA code equations overestimate the strength by about 13% and 24%.

References

  1. 1.
    Teng, J. G., Chen, J. F., Smith, S. T., & Lam, L. (2003). Behaviour and strength of FRP-strengthened RC structures: A state-of-the-art review. Proceedings of the institution of civil engineers Structures and Buildings, 156(1), 51–62.CrossRefGoogle Scholar
  2. 2.
    Bailey, C. G., & Yaqub, M. (2012). Seismic strengthening of shear critical post-heated circular concrete columns wrapped with FRP composite jackets. Composite Structures, 94(3), 851–864.CrossRefGoogle Scholar
  3. 3.
    Yaqub, M., Bailey, C. G., & Nedwell, P. (2011). Axial capacity of post-heated square columns wrapped with FRP composites. Cement and Concrete Composites, 33(6), 694–701.CrossRefGoogle Scholar
  4. 4.
    Bisby, L. A., Chen, J. F., Li, S. Q., Stratford, T. J., Cueva, N., & Crossling, K. (2011). Strengthening fire-damaged concrete by confinement with fibre-reinforced polymer wraps. Engineering Structures, 33(12), 3381–3391.CrossRefGoogle Scholar
  5. 5.
    Pellegrino, C., & Modena, C. (2010). Analytical model for FRP confinement of concrete columns with and without internal steel reinforcement. Journal of Composites for Construction, 14(6), 693–705.CrossRefGoogle Scholar
  6. 6.
    Rocca, S., Galati, N., & Nanni, A. (2008). Review of design guidelines for FRP confinement of reinforced concrete columns of noncircular cross sections. Journal of Composites for Construction, 12(1), 80–92.CrossRefGoogle Scholar
  7. 7.
    Campione, G., & Miraglia, N. (2003). Strength and strain capacities of concrete compression members reinforced with FRP. Cement and Concrete Composites, 25(1), 31–41.CrossRefGoogle Scholar
  8. 8.
    Rousakis, T. C. (2005). Mechanical behaviour of concrete confined by composite materials (Doctoral dissertation, PhD Thesis).Google Scholar
  9. 9.
    Mander, J. B., Priestley, M. J., & Park, R. (1988). Theoretical stress-strain model for confined concrete. Journal of Structural Engineering, 114(8), 1804–1826.CrossRefGoogle Scholar

Copyright information

© Springer International Publishing AG, part of Springer Nature 2018

Authors and Affiliations

  • Khaled A. Alawi Al-Sodani
    • 1
  • Muhammed K. Rahman
    • 2
  • Mohammed A. Al-Osta
    • 1
  • Ali A. H. Al-Gadhib
    • 1
    • 2
  1. 1.Department of Civil and Environmental EngineeringKing Fahd University of Petroleum and MineralsDhahranSaudi Arabia
  2. 2.Center for Engineering Research, Research InstituteKing Fahd University of Petroleum and MineralsDhahranSaudi Arabia

Personalised recommendations