Abstract

Data centers are one of the biggest energy consumers in the ICT sector. Their cooling system accounts for almost half of the overall data center energy demand. Thus, the flexibility in shifting energy demand of the cooling systems in data centers could be a great asset for data center operators. The amount of flexibility and how it can be maximized are important yet open problems, due to the several stochastic processes involved. In this paper, we propose a novel methodology that allows data center operators to compute the flexibility of the cooling system by modeling it as an Energy Storage System (ESS). To enable such a mapping, the temperature set-points of the cooling systems must be expressed by a recursive formulation. To this end, based on thermodynamic concepts, in this paper we derive a recursive formulation for the temperature of the cooling systems and verify it empirically through a real-world data set. We then sketch (as our future work) how this mapping can be used to compute the flexibility of the cooling systems which can be efficiently leveraged during demand-response periods.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Notes

  1. 1.

    https://www.ashrae.org/.

  2. 2.

    http://www.datacenterknowledge.com/archives/2008/10/14/google-raise-your-data-center-temperature/.

  3. 3.

    Please note that we use t as the time notation in a continuous-time model and k in a discrete-time model.

References

  1. Raeis, M., Burchard, A., Liebeherr, J.: Analysis of the leakage queue: a queuing model for energy storage systems with self-discharge. http://arxiv.org/abs/1710.09506

  2. Wang, D., Ren, C., Sivasubramaniam, A., Urgaonkar, B., Fathy, H.: Energy storage in datacenters: what, where, and how much? In: Proceedings of the ACM Sigmetrics/Performance, pp. 187–198 (2012)

    Google Scholar 

  3. Freeh, V.W., Lowenthal, D.K.: Using multiple energy gears in MPI programs on a power-scalable cluster. In: Proceedings of the Tenth ACM SIGPLAN Symposium on Principles and Practice of Parallel Programming, pp. 164–173. ACM (2005)

    Google Scholar 

  4. Greenberg, A., Hamilton, J., Maltz, D.A., Patel, P.: The cost of a cloud: research problems in data center networks. ACM SIGCOMM Comput. Commun. Rev. 39, 68–73 (2008)

    Article  Google Scholar 

  5. Ghiassi-Farrokhfal, Y., Keshav, S., Rosenberg, C.: Toward a realistic performance analysis of storage systems in smart grids. IEEE Trans. Smart Grid 6, 402–410 (2015)

    Article  Google Scholar 

  6. Ghiassi-Farrokhfal, Y., Keshav, S., Rosenberg, C., Ciucu, F.: Solar power shaping: an analytical approach. IEEE Trans. Sustain. Energ. 6, 162–170 (2015)

    Article  Google Scholar 

  7. Ghiassi-Farrokhfal, Y., Keshav, S., Rosenberg, C., Adjaho, M.-B: Joint optimal design and operation of hybrid energy storage systems. IEEE J. Sel. Area Commun. 34, pp. 639–650 (2016)

    Google Scholar 

  8. Code of Conduct on Data Centres Energy Efficiency, Version 2.0: European Commission. Institute for Energy, Renewable Energies Unit (2009)

    Google Scholar 

  9. Katz, R.H.: Tech titans building boom. IEEE Spec. 46, 40–56 (2009)

    Article  Google Scholar 

  10. Barroso, L.A., Clidaras, J., Hölzle, U.: The Datacenter as a Computer: An Introduction to the Design of Warehouse-Scale Machines. chapter 6, p. 96 (2013)

    Google Scholar 

  11. Meijer, G.I.: Cooling energy-hungry data centers. Science 328, 318–319 (2010)

    Article  Google Scholar 

  12. Assessment of Demand Response and Advanced Metering. Federal Energy Regulatory Commission (2013)

    Google Scholar 

  13. Basmadjian, R., Botero, J.F., Giuliani, G., Hesselbach, X., Klingert, S., de Meer, H.: Making data centres fit for demand response: introducing GreenSDA and GreenSLA contracts. IEEE Trans. Smart Grid (2016)

    Google Scholar 

  14. Piette, M.A., Girish, Gh., Sila, K., Koch, E., Hennage, D., Palensky, P., McParland, C.: Open Automated Demand Response Communications Specification (Version 1.0). LBNL (2009)

    Google Scholar 

  15. Ghatikar, G., Ganti, V., Matson, N., Piette, M.A.: Demand response opportunities and enabling technologies for data centers: Findings from field studies. Lawrence Berkeley National Laboratory, Technical report (2012)

    Google Scholar 

  16. Gellings, C., Chamberlin, J.H.: Demand-Side Management: Concepts and Methods. PennWell Books, Houston (1987)

    Google Scholar 

  17. Assessment of demand response and advanced metering. Federal Energy Regulatory Commission, Technical report (2010)

    Google Scholar 

  18. Aghaei, J., Alizadeh, M.-I.: Demand response in smart electricity grids equipped with renewable energy sources: a review. Renew. Sustain. Energ. Rev. 18, 64–72 (2013)

    Article  Google Scholar 

  19. Girish, G., Ganti, V., Matson, N., Piette, M.A.: Demand response opportunities and enabling technologies for data centers: findings from field studies. Lawrence Berkeley National Laboratory (2012)

    Google Scholar 

  20. Shehabi, A., Smith, S., Sartor, D.A., Brown, R.E., Herrlin, M., Koomey, J.G., Masanet, E.R., Horner, N., Azevedo, I., Lintner, W.: United States data center energy usage report. Lawrence Berkeley National Laboratory (2016)

    Google Scholar 

  21. El-Sayed, N., Stefanovici, I.A., Amvrosiadis, G., Hwang, A., Schroeder, B.: Temperature management in data centers: why some (might) like it hot. In: Proceedings of 12th International Conference on Measurement and Modeling of Computer Systems (2012)

    Google Scholar 

  22. Dynamic Cooling Control Provides Substantial Data Center Energy Savings. In: Air Conditioning, Heating & Refrigeration News (2013)

    Google Scholar 

  23. Kleyman, B.: Understanding the Benefits of Dynamic Cooling Optimization. White paper (2015)

    Google Scholar 

  24. Boucher, T.D., Auslander, D.M., Bash, C.E., Federspiel, C.C., Patel, C.D.: Viability of dynamic cooling control in a data center environment. J. Electron. Packaging 128, 137–144 (2006)

    Article  Google Scholar 

  25. Fenecon Energy Engineering. https://fenecon.de/en_US/page/stromspeicher

  26. Vishwanath, A., Chandan, V., Mendoza, C., Blake, C.: A data driven pre-cooling framework for energy cost optimization in commercial buildings. In: Proceedings of e-Energy. ACM (2017)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Robert Basmadjian .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Basmadjian, R., Ghiassi-Farrokhfal, Y., Vishwanath, A. (2018). Hidden Storage in Data Centers: Gaining Flexibility Through Cooling Systems. In: German, R., Hielscher, KS., Krieger, U. (eds) Measurement, Modelling and Evaluation of Computing Systems. MMB 2018. Lecture Notes in Computer Science(), vol 10740. Springer, Cham. https://doi.org/10.1007/978-3-319-74947-1_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-74947-1_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-74946-4

  • Online ISBN: 978-3-319-74947-1

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics