Skip to main content

Case 30: Blood Pressure Difference Between a Noninvasive and an Invasive Blood Pressure Measurement

  • Chapter
  • First Online:
Clinical Anesthesia

Abstract

A 54-year-old male (ASA3) is scheduled to undergo an automated implantable cardioverter-defibrillator (AICD) change under general anesthesia. His past history is remarkable for coronary artery disease, hypertension, and insulin-dependent diabetes mellitus. He is 230 lbs. and 5′5″. You meet him in the catheterization laboratory. As usual the place is in partial darkness and you are asked not to put on the light. So in the darkness you place noninvasive monitors. A right radial arterial line is secured prior to induction of anesthesia (Transpac IV monitoring kit. 84″ disposable transducers with a 3 ml squeeze flush. Abbott Critical Care System, Abbott Laboratory, North Chicago, IL.60064). A seemingly normal-appearing arterial waveform is present with a blood pressure of 149/116 mmHg and a mean of 129 mmHg. A simultaneous noninvasive blood pressure of 105/70 with a mean of 82 mmHg is obtained in the left arm. You change the noninvasive cuff to the right arm and get the same reading as in the left arm. The transducer is located in the midaxillary line and has been zeroed by you just before the arterial line was placed. Since you have just zeroed the transducer, you dismiss that as a cause for this difference in blood pressure reading. Furthermore, you did not see any offset when the stopcock was opened to atmosphere.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 89.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Eggen M, Brock-Utne JG. Artificial Increase in the arterial pressure Waveform: Remember the stopcock. Anesth Analg. 2005;101:298–9.

    Article  PubMed  Google Scholar 

  2. Truelsen KS, Brock-Utne JG. “Damping” of an Arterial Line: An Unlikely Cause. Anesth Analg. 1998;87:979–80.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Brock-Utne, J.G. (2017). Case 30: Blood Pressure Difference Between a Noninvasive and an Invasive Blood Pressure Measurement. In: Clinical Anesthesia. Springer, Cham. https://doi.org/10.1007/978-3-319-71467-7_30

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-71467-7_30

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-71466-0

  • Online ISBN: 978-3-319-71467-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics