A Novel Cyclic Convolution Based Regularization Method for Power-Line Interference Removal in ECG Signal

  • Conference paper
  • First Online:
Advances in Signal Processing and Intelligent Recognition Systems (SIRS 2017)

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 678))

Abstract

Applying signal processing to bio-signal record such as electrocardiogram or ECG signals provide vital insights to the details in diagnosis. The diagnosis will be exact when the extracted information about the ECG is accurate. However, these records usually gets corrupted/contaminated with several artifacts and power-line interferences (PLI) thereby affects the quality of diagnosis. Power-line interferences occurs in the range close to 50 Hz/60 Hz. The challenge is to remove the interferences without altering the original characteristics of ECG signal. Since the ECG signals frequency range is close to PLI, several articles discuss PLI removal methods which are mathematically complex and computationally intense. The present paper proposes a novel PLI removal method that uses a simple optimization method involving a circular convolution based \({\ell _2}\)-norm regularization. The solution is obtained in closed form and hence computationally simple and fast. The effectiveness of the proposed method is evaluated using output signal-to-noise-ratio (SNR) measure, and is found to be state-of-the-art.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Razzaq, N., Sheikh, S.A.A., Salman, M., Zaidi, T.: An intelligent adaptive filter for elimination of power line interference from high resolution electrocardiogram. IEEE Access 4, 1676–1688 (2016)

    Article  Google Scholar 

  2. https://en.wikipedia.org/wiki/Electrocardiography/media/File:SinusRhythmLabels.svg

  3. Dobrev, D.P., Neycheva, T.D.: Automatic common mode electrode-amplifier impedance balance with SPLL synchronization. In: 2016 XXV International Scientific Conference Electronics (ET), Sozopol, pp. 1–4 (2016)

    Google Scholar 

  4. Sharma, T., Sharma, K.K.: Power line interference removal from ECG signals using wavelet transform based component-retrieval. In: 2016 International Conference on Advances in Computing, Communications and Informatics (ICACCI), Jaipur, pp. 95–101 (2016)

    Google Scholar 

  5. Meidani, M., Mashoufi, B.: Introducing new algorithms for realising an FIR filter with less hardware in order to eliminate power line interference from the ECG signal. IET Signal Process. 10(7), 709–716 (2016)

    Article  Google Scholar 

  6. Warmerdam, G.J.J., Vullings, R., Schmitt, L., van Laar, J.O.E.H., Bergmans, J.W.M.: A fixed-lag Kalman smoother to filter power line interference in electrocardiogram recordings. IEEE Trans. Biomed. Eng. PP(99), 1 (2016)

    Google Scholar 

  7. Hu, X., Xiao, Z., Liu, C.: Reduction arithmetic for power line interference from ECG based on estimating sinusoidal parameters. In: 2010 3rd International Conference on Biomedical Engineering and Informatics, Yantai, pp. 2089–2092 (2010)

    Google Scholar 

  8. Vijendra, V., Kulkarni, M.: ECG signal filtering using DWT haar wavelets coefficient techniques. In: 2016 International Conference on Emerging Trends in Engineering, Technology and Science (ICETETS), Pudukkottai, pp. 1–6 (2016)

    Google Scholar 

  9. Tomasini, M., Benatti, S., Milosevic, B., Farella, E., Benini, L.: Power line interference removal for high-quality continuous biosignal monitoring with low-power wearable devices. IEEE Sens. J. 16(10), 3887–3895 (2016)

    Article  Google Scholar 

  10. Satija, U., Ramkumar, B., Manikandan, M.S.: Low-complexity detection and classification of ECG noises for automated ECG analysis system. In: 2016 International Conference on Signal Processing and Communications (SPCOM), Bangalore, pp. 1–5 (2016)

    Google Scholar 

  11. Ahlstrom, M.L., Tompkins, W.J.: Digital filters for real-time ECG signal processing using microprocessors. IEEE Trans. Biomed. Eng. 9, 708–713 (1985)

    Article  Google Scholar 

  12. Hamilton, P.S.: A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG. IEEE Trans. Biomed. Eng. 43, 105–109 (1996)

    Article  Google Scholar 

  13. Mishra, S., Das, D., Kumar, R., Sumathi, P.: A Power-Line Interference Canceler Based on Sliding DFT Phase Locking Scheme for ECG Signals. IEEE Trans. Instrum. Meas. 64, 132–142 (2015)

    Article  Google Scholar 

  14. Avendano-Valencia, L.D., Avendano, L.E., Ferrero, J.M., Castellanos-Dominguez, G: Improvement of an extended Kalman lter power line interference suppressor for ECG signals. IEEE Comput. Cardiol., pp. 553–556 (2007)

    Google Scholar 

  15. Bharath, H.N., Prabhu, K.M.M.: A new LMS based adaptive interference can-celler for ECG power line removal. In: 2012 International Conference on Biomedical Engineering (ICoBE), pp. 68–73 (2012)

    Google Scholar 

  16. Mohan, N., Kumar, S., Poornachandran, P., Soman, K.P.: Modied variational mode decomposition for power line interference removal in ECG signals. Int. J. Electric. Comput. Eng. (IJECE) 6 (2016)

    Google Scholar 

  17. Soman, K.P., Ramanathan, R.: Digital signal and image processing-the sparse way. Isa Publication (2012)

    Google Scholar 

  18. McSharry, P.E., Clifford, G.D., Tarassenko, L., Smith, L.A.: A dynamical model for generating synthetic electrocardiogram signals. IEEE Trans. Biomed. Eng. 50(3), 289–294 (2003)

    Article  Google Scholar 

  19. https://physionet.org/physiobank/database/mitdb/. Cited 22 March

  20. http://www.med.umich.edu/lrc/psbopen/html/repo/primerheartsound.html. Cited 22 March

  21. Manikandan, M.S., Soman, K.P.: Robust heart sound activity detection in noisy environments. Electron. Lett. 46(16), 1100–1102 (2010)

    Article  Google Scholar 

  22. Keshtkaran, M.R., Yang, Z.: A fast, robust algorithm for power line interference cancellation in neural recording. J. Neural Eng. 11, 026017 (2014)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. P. Soman .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this paper

Cite this paper

Sujadevi, V.G., Soman, K.P., Kumar, S.S., Mohan, N. (2018). A Novel Cyclic Convolution Based Regularization Method for Power-Line Interference Removal in ECG Signal. In: Thampi, S., Krishnan, S., Corchado Rodriguez, J., Das, S., Wozniak, M., Al-Jumeily, D. (eds) Advances in Signal Processing and Intelligent Recognition Systems. SIRS 2017. Advances in Intelligent Systems and Computing, vol 678. Springer, Cham. https://doi.org/10.1007/978-3-319-67934-1_11

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-67934-1_11

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-67933-4

  • Online ISBN: 978-3-319-67934-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics