Skip to main content

Development of a Wireless Security Monitoring System for CCEL

  • Conference paper
  • First Online:
Recent Developments in Mechatronics and Intelligent Robotics (ICMIR 2017)

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 690))

Included in the following conference series:

Abstract

A wireless security monitoring system is developed for chemistry and chemical engineering laboratories (CCEL) (or dangerous goods warehouses). The field information of each laboratory node is received through the handheld terminal, which realizes the functions of remote wireless monitoring and controlling. A wireless sensor node for CCEL was designed in this paper to detect the information such as fire, gas leaks, and abnormal sound in the laboratory. Once the insecure information is detected, the corresponding execution devices can be controlled according to the node’s decision algorithm. The detection and control information and the field image would be transmitted to the handheld terminal at the same time. It also can alarm quickly in order to minimize the risk of life and equipment loss in the laboratory. The experimental results show that the wireless security monitoring system developed in this paper can detect the on-line danger information in CCEL, so that the management personnel can monitor the safety status of the laboratory and take effective protection measures in time. Therefore, the system developed in this paper has applicative values.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Qiu, Q., Luo, Z.K., Lv, W.Z., Wang, F.: Investigation on university safety management of chemistry laboratory in domestic and abroad. Guangzhou Chem. Ind. 38(5), 272–274 (2010). (Chinese)

    Google Scholar 

  2. Bai, Z.W.: Application status and development trend of fire monitoring system in intelligent building. Secur. Sci. Technol. 2, 24–26 (2003). (Chinese)

    Google Scholar 

  3. Bao, M.Q., Zhang, Y., Zhang, S.C.: Analysis of college chemistry laboratory safety problems and exploration of safety management measures. Exp. Technol. Manag. 29(1), 188–191 (2012). (Chinese)

    Google Scholar 

  4. Nie, W., Xu, J., Liu, Y.: Design of automatic closed system about gas outburst monitor and its role of the reducing security cost. In: Proceedings of the 2nd International Conference Mine Hazards Prevention and Control, pp. 538–543. Atlantis Press, Paris (2010)

    Google Scholar 

  5. Wang, P., Wang, Z.: Design and implementation of open computer lab monitoring and management system. Comput. Mod. 11, 125–128 (2007)

    Google Scholar 

  6. Liu, Y.Q., Bao, H.G., Song, S.J.: Research on university laboratory safety management. Exp. Sci. Technol. 10(1), 173–175 (2012). (Chinese)

    Google Scholar 

  7. Qiu, N.W., An, X.C., Jia, J.W.: Challenges and solutions confronted with for laboratory safety management in colleges and universities during new period. Exp. Technol. Manag. 29(1), 181–185 (2012). (Chinese)

    Google Scholar 

  8. Feng, J., Xiong, W., Qiu, H.D., Long, Y.X.: Exploration on strengthening the safety of chemistry and chemical engineering laboratory. Guangdong Chem. Eng. 43(6), 209–210 (2016). (Chinese)

    Google Scholar 

  9. Qiu, H.D., Li, G., Wang, W., Long, Y.X.: Comparison on safety management of chemistry and chemical engineering laboratories between universities of China and United States. Exp. Technol. Manag. 31(4), 203–209 (2014). (Chinese)

    Google Scholar 

  10. Li, Z.M., Chen, X.G., Wu, L., Wei, Y.F.: Fault diagnosis method for wireless security monitoring system in chemistry and chemical engineering laboratory. Trans. Beijing Inst. Technol. 35(10), 1062–1066 (2015). (Chinese)

    Google Scholar 

Download references

Acknowledgements

Scientific research in this paper was supported by the Instrumentation Developed Project of Beijing Institute of Technology.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiang-guang Chen .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Liu, Xj., Chen, Xg., Li, Zm., Du, N., Tang, Lt. (2018). Development of a Wireless Security Monitoring System for CCEL. In: Qiao, F., Patnaik, S., Wang, J. (eds) Recent Developments in Mechatronics and Intelligent Robotics. ICMIR 2017. Advances in Intelligent Systems and Computing, vol 690. Springer, Cham. https://doi.org/10.1007/978-3-319-65978-7_12

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-65978-7_12

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-65977-0

  • Online ISBN: 978-3-319-65978-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics