Abstract

The RotaWire is very different from a standard coronary guidewire. Its construction prevents unravelling by the rotation of the burr. It is a 325 cm stainless steel, short spring-tipped guidewire. The shaft of the RotaWire is 0.009″. It tapers mainly in the last 13 cm proximal. The spring tip is 0.014″ in diameter and 2.2 cm in length and can be shaped (Fig. 1.1). There is also an extra-support RotaWire with a slightly longer tip (2.8 cm) and stiffer shaft (Fig. 1.2). The thicker wire tip also prevents the burr from going past the shaft of the wire. This is important in helping prevent inadvertent coronary artery perforations. The wire is very easy to kink. During advancement or removal or exchange of the burr, it is critical not to kink the wire. Kinking of the wire will result in difficulty removing or advancing the burr and can result in loss of wire position.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   59.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   79.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Acknowledgements

We would like to acknowledge and thank Boston Scientific for providing the figures in this chapter.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Khung Keong Yeo MBBS .

Editor information

Editors and Affiliations

Electronic Supplementary Materials

Loading of rotaburr on RotaWire (MP4 71172 kb)

Advancement of rotaburr (MP4 134558 kb)

Sandpapering technique of rotablation (MP4 103360 kb)

Removal of rotaburr (MP4 41792 kb)

Attachment of new burr. In this segment, the burr is removed and then reattached (MOV 126746 kb)

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this chapter

Cite this chapter

Yap, J., Yeo, K.K., Teo, T., Low, R. (2018). Overview of Equipment and Procedure. In: Low, R., Yeo, K. (eds) Clinical Cases in Coronary Rotational Atherectomy. Clinical Cases in Interventional Cardiology. Springer, Cham. https://doi.org/10.1007/978-3-319-60490-9_1

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-60490-9_1

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-60488-6

  • Online ISBN: 978-3-319-60490-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics