Skip to main content

Critical Appraisal of Cardiac Implantable Electronic Devices: Complications and Management

  • Chapter
  • First Online:
Psychological, Emotional, Social and Cognitive Aspects of Implantable Cardiac Devices

Abstract

Pacemakers, defibrillators and cardiac resynchronization devices (CIEDs) should not only meet regulatory requirements, but ideally also the expectations of medical staff and patients. Unfortunately, most of these clinical recommendations are fairly vague, and not related to specific products or malfunctions, but rather to some concept of overall performance. This may be entirely appropriate as the myriad of potential individual malfunctions can hardly be expected to be anticipated by medical staffs. This chapter will discuss some potential malfunctions, and how variable patient harms and complications may be for different malfunctions. The individual risks of patient harm considered together with their needs dictate recommendations for management of the malfunction.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  1. Swerdlow CD, Asirvatham SJ, Ellenbogen KA, Friedman PA. Troubleshooting implanted cardioverter defibrillator sensing problems I. Circ Arrhythm Electrophysiol. 2014;7:1237–61. doi:10.1161/CIRCEP.114.002344.

    Article  PubMed  Google Scholar 

  2. Doshi H, Reddy S, Root M, Sharma AD. Engineering aspects of pacemakers and leads. Chapter 30. In: Saksena S, Camm AJ, editors. Electrophysiologic disorders of the heart: expert consult. Elsevier/Saunders; 2012. isbn 1437702856, 9781437702859.

    Google Scholar 

  3. Maisel WH, Moynahan M, Zuckerman BD, Gross TP, Tovar OH, Tillman D-B, Schultz DB. Pacemaker and ICD generator malfunctions: analysis of food and drug administration annual reports. JAMA. 2006;295(16):1901–6. doi:10.1001/jama.295.16.1901.

    Article  CAS  PubMed  Google Scholar 

  4. Poole JE, Gleva MJ, Mela T, Chung MK, et al. for the REPLACE Registry Investigators. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry. Circulation. 2010;122:1553–61. doi:10.1161/CIRCULATIONAHA.110.976076.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Arjun D. Sharma M.D., F.A.C.C. .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this chapter

Cite this chapter

Sharma, A.D. (2017). Critical Appraisal of Cardiac Implantable Electronic Devices: Complications and Management. In: Proietti, R., Manzoni, G., Pietrabissa, G., Castelnuovo, G. (eds) Psychological, Emotional, Social and Cognitive Aspects of Implantable Cardiac Devices. Springer, Cham. https://doi.org/10.1007/978-3-319-55721-2_7

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-55721-2_7

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-55719-9

  • Online ISBN: 978-3-319-55721-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics