Abstract
Image guided radiotherapy (IGRT) in pediatrics provides a means for reduction of treatment volumes by permitting for the use of highly conformal plans with smaller treatment margins. IGRT may additionally allow for dose escalation and adaptive radiotherapy strategies. Current practice patterns and clinical protocols support the use of weekly or daily IGRT as standard practice in pediatric brain-directed IGRT. However, the benefits of IGRT must be weighed against its costs including potentially significant additional radiation dose, supporting the need to study lower dose IGRT protocols in this population. This chapter reviews common modalities of IGRT and the literature regarding its use specific to pediatric brain radiotherapy.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
AAPM (2009) The role of in-room kV X-ray imaging for patient setup and target localization. Report of AAPM Task Group 104. In: American Association of Physicists in Medicine. Medical Physics Publishing, Madison, WI
Ahunbay EE, Peng C, Holmes S et al (2010) Online adaptive replanning method for prostate radiotherapy. Int J Radiat Oncol Biol Phys 77:1561–1572. doi:10.1016/j.ijrobp.2009.10.013
Alcorn SR, Chen MJ, Claude L et al (2014a) Practice patterns of photon and proton pediatric image guided radiation treatment: results from an International Pediatric Research Consortium. Pract Radiat Oncol 4(5):336–341. doi:10.1016/j.prro.2014.03.014
Alcorn S, Nilsson K, McNutt T et al (2014b) Low-dose cone-beam CT protocol for image-guided CNS radiotherapy: predictors of setup accuracy from a multinational pediatric consortium. In: SIOP 46th Congress, Toronto
Antonuk LE (2002) Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research. Phys Med Biol 47:R31–R65. doi:10.1088/0031-9155/47/6/201
Beltran C, Naik M, Merchant TE (2009) Role of adaptive radiotherapy in pediatric craniopharyngioma. In: ASTRO 51st annual meeting
Beltran C, Pegram A, Merchant TE (2012) Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patients. Radiother Oncol 102:206–209. doi:10.1016/j.radonc.2011.06.013
Bucci M, Dong L, Liao Z et al (2007) Comparison of tumor shrinkage in proton and photon radiotherapy of lung cancer. In: ASTRO 49th annual meeting
Cao Y (2011) The promise of dynamic contrast-enhanced imaging in radiation therapy. Semin Radiat Oncol 21:147–156. doi:10.1016/j.semradonc.2010.11.001
Castadot P, Lee JA, Geets X, Grégoire V (2010) Adaptive radiotherapy of head and neck cancer. Semin Radiat Oncol 20:84–93. doi:10.1016/j.semradonc.2009.11.002
Chauvet B, de Rauglaudre G, Mineur L et al (2003) [Dose-response relationship in radiotherapy: an evidence?]. Cancer Radiother 7 Suppl 1:8s–14s
Chen CC, Chapman P, Petit J, Loeffler J (2007) Proton radiosurgery in neurosurgery. Neurosurg Focus 23:E5. doi:10.3171/FOC-07/12/E5
Dawson LA, Jaffray DA (2007) Advances in image-guided radiation therapy. J Clin Oncol 25:938–946. doi:10.1200/JCO.2006.09.9515
De Crevoisier R, Kuban D, Lefkopoulos D (2006) Radiothérapie guidée par tomodensitométrie associée à l’accélérateur linéaire dans la salle de traitement. Cancer/Radiotherapie 10:245–251. doi:10.1016/j.canrad.2006.06.004
Ding GX, Coffey CW (2009) Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 73:610–617. doi:10.1016/j.ijrobp.2008.10.006
Dong L (2012) What do we know about adaptive radiotherapy? In: AAMD region II meeting, Houston
Engelsman M, Schwarz M, Dong L (2013) Physics controversies in proton therapy. Semin Radiat Oncol 23:88–96. doi:10.1016/j.semradonc.2012.11.003
Frank SJ, Dong L, Kudchadker RJ et al (2008) Quantification of prostate and seminal vesicle interfraction variation during IMRT. Int J Radiat Oncol Biol Phys 71:813–820. doi:10.1016/j.ijrobp.2007.10.028
Fu D, Kuduvalli G (2008) A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery. Med Phys 35:2180–2194. doi:10.1118/1.2903431
Goyal S, Kataria T (2014) Image guidance in radiation therapy: techniques and applications. Radiol Res Pract 2014:1–10. doi:10.1155/2014/705604
Grégoire V, Mackie TR (2011) State of the art on dose prescription, reporting and recording in Intensity-Modulated Radiation Therapy (ICRU report No. 83). Cancer Radiother 15:555–559. doi:10.1016/j.canrad.2011.04.003
Gupta T, Narayan CA (2012) Image-guided radiation therapy: physician’s perspectives. J Med Phys 37:174–182. doi:10.4103/0971-6203.103602
Hitchen CJ, Osa E-O, Dewyngaert JK et al (2012) Dose to craniofacial region through portal imaging of pediatric brain tumors. J Appl Clin Med Phys 13:3385
Huynh-Le M-P, Alcorn S, Smith K et al (2014) Comparison of setup accuracy with low-dose vs. standard-dose CBCT in pediatric and adult brain image-guided radiotherapy. In: ASTRO 56th annual meeting, San Francisco
Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA (2002) Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53:1337–1349. doi:10.1016/S0360-3016(02)02884-5
Jaffray D, Kupelian P, Djemil T, Macklis RM (2007) Review of image-guided radiation therapy. Expert Rev Anticancer Ther 7:89–103. doi:10.1586/14737140.7.1.89
Kim S, Yoshizumi TT, Frush DP et al (2010) Radiation dose from cone beam CT in a pediatric phantom: risk estimation of cancer incidence. Am J Roentgenol 194:186–190. doi:10.2214/AJR.08.2168
Michalski J, Purdy JA, Gaspar L et al (2001) Radiation Therapy Oncology Group. Research Plan 2002-2006. Image-Guided Radiation Therapy Committee. Int J Radiat Oncol Biol Phys 51:60–65. doi:10.1038/358375a0
Nishio T, Miyatake A, Ogino T et al (2010) The development and clinical use of a beam ON-LINE PET system mounted on a rotating gantry port in proton therapy. Int J Radiat Oncol Biol Phys 76:277–286. doi:10.1016/j.ijrobp.2009.05.065
Pollack A, Zagars GK, Starkschall G et al (2002) Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial. Int J Radiat Oncol Biol Phys 53:1097–1105
Ruchala KJ, Olivera GH, Schloesser EA, Mackie TR (1999) Megavoltage CT on a tomotherapy system. Phys Med Biol 44:2597–2621. doi:10.1088/0031-9155/44/10/316
Stroom JC, Heijmen BJM (2002) Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiother Oncol 64:75–83. doi:10.1016/S0167-8140(02)00140-8
Van Herk M (2004) Errors and margins in radiotherapy. Semin Radiat Oncol 14:52–64
Van Herk M (2011) Margins and margin recipes. In: AAPM Summer School
Verellen D, De Ridder M, Storme G (2008) A (short) history of image-guided radiotherapy. Radiother Oncol 86:4–13. doi:10.1016/j.radonc.2007.11.023
Zhang Y, Yan Y, Nath R et al (2012) Personalized assessment of kV cone beam computed tomography doses in image-guided radiotherapy of pediatric cancer patients. Int J Radiat Oncol Biol Phys 83:1649–1654. doi:10.1016/j.ijrobp.2011.10.072
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this chapter
Cite this chapter
Alcorn, S., Terezakis, S. (2018). Image Guidance in Pediatric Brain Radiotherapy. In: Mahajan, A., Paulino, A. (eds) Radiation Oncology for Pediatric CNS Tumors. Springer, Cham. https://doi.org/10.1007/978-3-319-55430-3_24
Download citation
DOI: https://doi.org/10.1007/978-3-319-55430-3_24
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-55428-0
Online ISBN: 978-3-319-55430-3
eBook Packages: MedicineMedicine (R0)