Abstract
Besides the determination of the electron mass and the g-factor difference of lithiumlike calcium isotopes, which have been presented in this thesis, further exciting bound-electron g-factor measurements have been performed in the medium-Z range in the previous years, e.g. the measurements of hydrogenlike and lithiumlike silicon, see [1, 2].
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Notes
- 1.
The production of hydrogenlike calcium requires electron beam energies in excess of \(E_\text {ion}=5.128\, \text {keV}.\) During our last creation attempts several flash-arcs limited the maximal applied high-voltage. Most of the time they occurred in the high-voltage box connected to the hat flange, see Sect. 4.1.2. Moreover, the FEP has been destroyed once during a creation cycle and had to be replaced in a time-consuming repairing.
- 2.
Here, also the 15 \(\upmu \mathrm{m}\) gold/silver layers have been considered.
References
Sturm, S., Wagner, A., Schabinger, B., Zatorski, J., Harman, Z., Quint, W., Werth, G., Keitel, C.H., Blaum, K.: ‘g factor of hydrogenlike \(^{28}{\rm Si}^{13+}\)’. Phys. Rev. Lett. 107(2), 023002 (2011)
Wagner, A., Sturm, S., Köhler, F., Glazov, D.A., Volotka, A.V., Plunien, G., Quint, W., Werth, G., Shabaev, V.M., Blaum, K.: ‘g factor of lithiumlike silicon \(^{28}{\rm Si}^{11+}\)’. Phys. Rev. Lett. 110(3), 033003 (2013)
Quint, W., Moskovkhin, D.L., Shabaev, V.M., Vogel, M.: ‘Laser-microwave double-resonance technique for g-factor measurements in highly charged ions’. Phys. Rev. A 78(3), 032517 (2008)
von Lindenfels, D., Brantjes, N.P.M., Birkl, G., Quint, W., Shabaev, V.M., Vogel, M.: ‘Bound electron g-factor measurement by double-resonance spectroscopy on a fine-structure transition’. Can. J. Phys. 89(1), 79–84 (2011)
Gabrielse, G., Haarsma, L., Rolston, S.L.: ‘Open-endcap penning traps for high precision experiments’. Int. J. Mass Spectrom. Ion Process. 88, 319–332 (1989)
Röux, C., Bohm, C., Dörr, A., Eliseev, S., George, S., Goncharov, M., Novikov, Y.N., Repp, J., Sturm, S., Ulmer, S., Blaum, K.: ‘The trap design of PENTATRAP’. Appl. Phys. B 107(4), 997–1005 (2012)
Roux, C.-E.: It high-resolution mass spectrometry: the trap design and detection system of PENTATRAP and new Q-values for neutrino studies. Doktorarbeit (2012)
Ulmer, S.: First observation of spin flips with a single proton stored in a cryogenic penning trap. Doktorarbeit (2011)
MATLAB: version 8.1.0.604 (R2013a). Natick, Massachusetts, USA: The Math- Works Inc., (2013)
Lagarias, J.C., Jeffrey, C., Reeds, J.A., Wright, M.H., Wright, P.E.: ‘Convergence properties of the Nelder–Mead simplex method in low dimensions’. SIAM J. Optim. 9(1), 112–147 (1998)
Ketter, J., Eronen, T., Hocker, M., Streubel, S., Blaum, K.: ‘Firstorder perturbative calculation of the frequency-shifts caused by static cylindrically-symmetric electric and magnetic imperfections of a Penning trap’. Int. J. Mass 358(0), 1–16 (2014)
Mooser, A., Kracke, H., Blaum, K., Brauninger, S.A., Franke, K., Leiteritz, C., Quint, W., Rodegheri, C.C., Ulmer, S., Walz, J.: ‘Resolution of single spin flips of a single proton’. Phys. Rev. Lett. 110(14), 140405 (2013)
Mooser, A.: Der g-Faktor des Protons. Doktorarbeit (2013)
Repp, J.: The setup of the high-precision Penning-trap mass spectrometer PENTATRAP and first production studies of highly charged ions. Doktorarbeit (2012)
Kluge, H.-J. et al.: ‘Chapter 7 HITRAP: a facility at GSI for highly charged ions’. In: Salomonson, S., Lindroth, E. (eds.) Current Trends in Atomic Physics, Advances in Quantum Chemistry, vol. 53, pp. 83–98. Academic Press, New York (2008)
Crespo López-Urrutia, J.R., Dorn, A., Moshammer, R., Ullrich, J.: ‘The Freiburg electron beam ion trap/source project FreEBIT’. Phys. Scr. 1999(T80B), 502 (1999)
von Lindenfels, D., Wiesel, M., Glazov, D.A., Volotka, A.V., Sokolov, M.M., Shabaev, V.M., Plunien, G., Quint, W., Birkl, G., Martin, A., Vogel, M.: ‘Experimental access to higher-order Zeeman effects by precision spectroscopy of highly charged ions in a Penning trap’. Phys. Rev. A 87(2), 023412 (2013)
Shabaev, V.M., Glazov, D.A., Shabaeva, M.B., Yerokhin, V.A., Plunien, G., Soff, G.: ‘g factor of high-Z lithiumlike ions’. Phys. Rev. A 65(6), 062104 (2002)
Shabaev, V.M., Glazov, D.A., Oreshkina, N.S., Volotka, A.V., Plunien, G., Kluge, H.-J., Quint, W.: ‘g-factor of heavy ions: a new access to the fine structure constant’. Phys. Rev. Lett. 96(25), 253002 (2006)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2017 Springer International Publishing AG
About this chapter
Cite this chapter
Köhler-Langes, F. (2017). Outlook - A New Generation of High-Precision Penning Trap. In: The Electron Mass and Calcium Isotope Shifts. Springer Theses. Springer, Cham. https://doi.org/10.1007/978-3-319-50877-1_7
Download citation
DOI: https://doi.org/10.1007/978-3-319-50877-1_7
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-50876-4
Online ISBN: 978-3-319-50877-1
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)