Abstract
Instantaneous wave free ratio (iFR) may be a viable alternative to FFR. iFR is a novel measurement of the hemodynamic relevance of coronary lesions which doesn’t require the use of hyperemic agents.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Sen S, Escaned J, Malik IS, Mikhail GW, Foale RA, Mila R, et al. Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis: results of the ADVISE (ADenosine Vasodilator Independent Stenosis Evaluation) study. J Am Coll Cardiol. 2012;59:1392–402.
Sen S, Asrress KN, Nijjer S, Petraco R, Malik IS, Foale RA, et al. Diagnostic classification of the instantaneous wave-free ratio is equivalent to fractional flow reserve and is not improved with adenosine administration. Results of CLARIFY (Classification Accuracy of Pressure-Only Ratios Against Indices Using Flow Study. J Am Coll Cardiol. 2013;61:1409–20.
Sen S, Escaned J, Malik IS, Mikhail GW, Foale RA, Mila R, et al. Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis: results of the ADVISE (ADenosine Vasodilator Independent Stenosis Evaluation) study. J Am Coll Cardiol. 2012;59(15):1392–402.
Berry C, van ‘t Veer M, Witt N, Kala P, Bocek O, Pyxaras SA, et al. VERIFY (VERification of Instantaneous Wave-Free Ratio and Fractional Flow Reserve for the Assessment of Coronary Artery Stenosis Severity in EverydaY Practice): a multicenter study in consecutive patients. J Am Coll Cardiol. 2013;61(13):1421–27.
Johnson NP, Kirkeeide RL, Asrress KN, Fearon WF, Lockie T, Marques KM, et al. Does the instantaneous wave-free ratio approximate the fractional flow reserve? J Am Coll Cardiol. 2013;61(13):1428–35.
de Waard GA, Danad I, Petraco R, Teunissen PF, van de Hoef TP, Raijmakers PG, et al. Hyperemic FFR and Baseline iFR Have an Equivalent Diagnostic Accuracy When Compared to Myocardial Blood Flow Quantified by H215O PET Perfusion Imaging. J Am Coll Cardiol. 2015;63(12). Abstract.
Petraco R, Park JJ, Sen S, Nijjer SS, Malik IS, Echavarria-Pinto M, et al. Hybrid iFR-FFR decision-making strategy: implications for enhancing universal adoption of physiology-guided coronary revascularisation. EuroIntervention. 2013;8(10):1157–65.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing AG
About this chapter
Cite this chapter
Götberg, M. (2016). Instantaneous Wave-Free Ratio Assessment. In: Gori, T., Fineschi, M. (eds) Atlas of FFR-Guided Percutaneous Coronary Interventions. Springer, Cham. https://doi.org/10.1007/978-3-319-47116-7_13
Download citation
DOI: https://doi.org/10.1007/978-3-319-47116-7_13
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-47114-3
Online ISBN: 978-3-319-47116-7
eBook Packages: MedicineMedicine (R0)