Skip to main content

Simulation of Dose Reduction in Digital Breast Tomosynthesis

  • Conference paper
  • First Online:
Book cover Breast Imaging (IWDM 2016)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 9699))

Included in the following conference series:

Abstract

Clinical evaluation of dose reduction studies in x-ray breast imaging is problematic because it is difficult to justify imaging the same patient at a variety of radiation doses. One common alternative is to use simulation algorithms to manipulate a standard-dose exam to mimic reduced doses. Although there are several dose-reduction simulation methods for full-field digital mammography, the availability of similar methods for digital breast tomosynthesis (DBT) is limited. This work proposes a method for simulating dose reductions in DBT, based on the insertion of noise in a variance-stabilized domain. The proposed method has the advantage of performing signal-dependent noise injection without knowledge of the noiseless signal. We compared clinical low-dose DBT projections and reconstructed slices to simulated ones by means of power spectra, mean pixel values, and local standard deviations. The results of our simulations demonstrate low error (<5 %) between real and simulated images.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Samei, E., Eyler, W., Baron, L.: Effects of anatomical structure on signal detection. In: Handbook of Medical Imaging, pp. 655–682 (2000)

    Google Scholar 

  2. Saunders, R.S., Samei, E.: A method for modifying the image quality parameters of digital radiographic images. Med. Phys. 30, 3006–3017 (2003)

    Article  Google Scholar 

  3. Båth, M., Håkansson, M., Tingberg, A., Månsson, L.G.: Method of simulating dose reduction for digital radiographic systems. Radiat. Prot. Dosimetry 114, 253–259 (2005)

    Article  Google Scholar 

  4. Kroft, L.J.M., Veldkamp, W.J.H., Mertens, B.J.A., Van Delft, J.P.A., Geleijns, J.: Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography. Radiology 241(2), 392–398 (2006)

    Article  Google Scholar 

  5. Veldkamp, W.J.H., Kroft, L.J.M., Van Delft, J.P.A., Geleijns, J.: A technique for simulating the effect of dose reduction on image quality in digital chest radiography. J. Digit. Imaging 22(2), 114–125 (2009)

    Article  Google Scholar 

  6. Svalkvist, A., Båth, M.: Simulation of dose reduction in tomosynthesis. Med. Phys. 37, 258–269 (2010)

    Article  Google Scholar 

  7. Mackenzie, A., Dance, D.R., Workman, A., Yip, M., Wells, K., Young, K.C.: Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system. Med. Phys. 39, 2721 (2012)

    Article  Google Scholar 

  8. Mackenzie, A., Dance, D.R., Diaz, O., Young, K.C.: Image simulation and a model of noise power spectra across a range of mammographic beam qualities. Med. Phys. 41, 121901-1–121901-14 (2014)

    Article  Google Scholar 

  9. Borges, L.R., Oliveira, H.C.R., Nunes, P.F., Vieira, M.A.C.: Method for inserting noise in digital mammography to simulate reduction in radiation dose. In: Proceedings of the SPIE 9412, Medical Imaging, 94125J (2015)

    Google Scholar 

  10. Cockmartin, L., Bakic, P.R., Bosmans, H., Maidment, A.D., Gall, H., Zerhouni, M., Marshall, N.W.: Power spectrum analysis of an anthropomorphic breast phantom compared to patient data in 2D digital mammography and breast tomosynthesis. In: Fujita, H., Hara, T., Muramatsu, C. (eds.) IWDM 2014. LNCS, vol. 8539, pp. 423–429. Springer, Heidelberg (2014)

    Google Scholar 

Download references

Acknowledgements

The authors would like to thank São Paulo Research Foundation (FAPESP grant# 2013/18915-5) and the Brazilian Foundation for the Coordination of Improvement of Higher Education Personnel (CAPES grant# 88881.030443/2013-01) for the financial support given to this project. The authors would also like to acknowledge the support of the National Institutes of Health/National Cancer Institute grant 1R01-CA154444. The content of this paper is solely the responsibility of the authors and does not necessarily represent the official views of the funding agencies. We thank Real Time Tomography (RTT) for providing assistance with image reconstruction. ADAM is a member of the scientific advisory board and shareholder of RTT.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lucas R. Borges .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this paper

Cite this paper

Borges, L.R., Guerrero, I., Bakic, P.R., Maidment, A.D.A., Schiabel, H., Vieira, M.A.C. (2016). Simulation of Dose Reduction in Digital Breast Tomosynthesis. In: Tingberg, A., Lång, K., Timberg, P. (eds) Breast Imaging. IWDM 2016. Lecture Notes in Computer Science(), vol 9699. Springer, Cham. https://doi.org/10.1007/978-3-319-41546-8_43

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-41546-8_43

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-41545-1

  • Online ISBN: 978-3-319-41546-8

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics