Abstract
Use of dental implants in case of missing natural dentition is now common in clinical dentistry. The tilted implant configurations, which are inevitable in many clinical situations, are prone to higher stresses. The orientation of implants has a great influence on its structural integrity as high stresses around the implants adversely affect the osseointegration process and eventually fail due to the bone resorption. Hence, complete understanding of such complex systems demand better understanding of the bio-mechanics involved. Photoelasticity, a whole-field optical technique, is the right choice for analysing such implant configurations. Recent advancements in digital photoelasticity make it possible to evaluate isochromatics as well as isoclinic parameters over the entire model domain with considerable accuracy. However, these techniques have not been exploited in the field of implant dentistry and photoelasticity has been mostly used as a visualisation tool. This paper explores the use of modern photoelastic techniques for analysing the stress distribution due to an implant with an inclination of 15°. Further, this work also studies the high stress zones in the coronal region of this angled implant. The isochromatic data is post processed using least squares method for determining the contact parameters such as effective contact length and frictional coefficient.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Maló, P., Rangert, B., Nobre, M.: All-on-Four® immediate-function concept with Brånemark System® implants for completely edentulous mandibles: a retrospective clinical study. Clin. Implant. Dent. Relat. Res. 5(1), 2–9 (2003)
Ramesh, K.: Digital Photoelasticity: Advanced Techniques and Applications. Springer, Berlin (2000)
Ramesh, K.: Digital photoelasticity. In: Rastogi, P. (ed.) Digital Optical Measurement Techniques and Applications, pp. 289–344. Artech House, London (2015)
Ten Bruggemkate, C.M., Sutter, F., Oosterbeek, H.S., Schroeder, A.: Indications of angled implants. J. Prosthet. Dent. 67, 85–93 (1992)
Begg, T., Geerts, G.A., Gryzagoridis, J.: Stress patterns around distal angled implants in the All-on-Four concept configuration. Int. J. Oral Maxillofac. Implants 67, 663–693 (2009)
Asvanund, P., Morgano, S.M.: Photoelastic stress analysis of external versus internal implant-abutment connections. J. Prosthet. Dent. 106(4), 266–271 (2011)
Rossi, F., Zavanelli, A.C., Zavanelli, R.A.: Photoelastic comparison of single tooth implant-abutment- bone of platform switching vs conventional implant designs. J. Contemp. Dent. Pract. 12(2), 124–130 (2011)
Ashokan, K., Prasath, R.G.R., Ramesh, K.: Noise-free determination of isochromatic parameter of stereolithography-built models. Exp. Tech. 36(1), 70–75 (2012)
Hariprasad, M.P., Bhuvaneswari, S., Ramesh, K., Simon, P., Mohan, J.: Evolution of suitable photoelastic model in implant dentistry. In: Proceedings of 9th International Symposium on Advanced Science and Technology in Experimental Mechanics (9th ISEM 14), New Delhi, 1–6 November 2014
Ramesh, K., Deshmukh, S.S.: Three fringe photoelasticity—use of colour image processing hardware to automate ordering of isochromatics. Strain 32(3), 79–86 (1996)
Kale, S., Ramesh, K.: Advancing front scanning approach for three-fringe photoelasticity. Opt. Lasers Eng. 51, 592–599 (2013)
Caram, S.J., Huynh-Ba, G., Schoolfield, J.D., Jones, A.A., Cochran, D.L., Belser, U.C.: Biologic width around different implant-abutment interface configurations. A radiographic evaluation of the effect of horizontal offset and concave abutment profile in the canine mandible. Int. J. Oral Maxillofac. Implants 29, 1114–1122 (2014)
Sukla, A., Nigam, H.: A numerical-experimental analysis of the contact stress problem. J. Strain Anal. Eng. Des. 20(4), 241–245 (1985)
Smith, J.O., Liu, C.K.: Stresses due to tangential and normal loads on an elastic solid with application to some contact stress problems. J. Appl. Mech. 20, 157–166 (1953)
Acknowledgment
The authors would like to acknowledge Dr. Bhuvaneswari. S, from Vinayaka Mission’s Sankaracharyar Dental College- Salem, India, for helping in the model preparation for this study.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 The Society for Experimental Mechanics, Inc.
About this paper
Cite this paper
Hariprasad, M.P., Ramesh, K. (2017). Contact Zone Evaluation of Dental Implants Using Digital Photoelasticity. In: Korach, C., Tekalur, S., Zavattieri, P. (eds) Mechanics of Biological Systems and Materials, Volume 6. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, Cham. https://doi.org/10.1007/978-3-319-41351-8_6
Download citation
DOI: https://doi.org/10.1007/978-3-319-41351-8_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-41350-1
Online ISBN: 978-3-319-41351-8
eBook Packages: EngineeringEngineering (R0)