Abstract
This paper proposed a novel three-channel self-pressurized wrist pulse acquisition system based on the principle of wrist pulse diagnosis in Traditional Chinese Medicine (TCM). This proposed acquisition system could not only sample, display, analyze and store the wrist pulses in Cun, Guan and Chi region of the wrist simultaneously under the best pulse taking force, but also simulate the process of wrist pulse diagnosis in TCM clinical science called “three regions and nine pulse takings”. It is believed that this proposed system solved the problem that most of the current pulse acquisition systems could only detect the pulse in Guan region of the wrist. The result shows that the proposed acquisition system provided a user-friendly flexible sample collection platform, laid the foundation for further analysis of multi-channel wrist pulses and pushed forward the development of the standardization of wrist pulse waveforms and the objectification of wrist pulse diagnosis in TCM.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Jingtang, L.: The objective detection and description of the types of pulse based on the Chinese traditional medical science (中医脉象的客观描述和检测). Chin. J. Med. Instrum. 25(6), 318–323 (2001)
Zhaofu, F.: Contemporary Sphygmology in Traditional Chinese Medicine (现代中医脉诊学). People’s Medical Publishing House Co., Ltd, Beijing (2003)
Weichang, T., Rui, L.: Research on the Cun-Guan-Chi pulse detecting system (三部脉象检测系统的研究). Chin. J. Med. Instrum. 29(3), 164–166 (2005)
Jingjing, W., Congying, L., Xinhong, J., Yuping, Z., Weichang, T.: Research for the largest and safe pressure in the pulse testing (脉象检测中最大取脉压力和人体耐受安全值的研究). Liaoning J. Tradit. Chin. Med. 37(4), 582–584 (2010)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this paper
Cite this paper
Kan-heng, Z., Peng, Q., Chun-ming, X., Yi-qin, W. (2015). Research on a Novel Three-Channel Self-pressurized Wrist Pulse Acquisition System. In: Fred, A., Gamboa, H., Elias, D. (eds) Biomedical Engineering Systems and Technologies. BIOSTEC 2015. Communications in Computer and Information Science, vol 574. Springer, Cham. https://doi.org/10.1007/978-3-319-27707-3_4
Download citation
DOI: https://doi.org/10.1007/978-3-319-27707-3_4
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-27706-6
Online ISBN: 978-3-319-27707-3
eBook Packages: Computer ScienceComputer Science (R0)