Abstract
The system description of the controllable grid interface (CGI) and the commercial multi-megawatt sized type 4 wind turbine generator (WTG) installed at the National Renewable Energy Laboratory (NREL) was presented in Chap. 7. Detailed, generic electromagnetic transient (EMT) models of the CGI and the WTG were developed in Chap. 8. The purpose of this chapter is the evaluation of said models. The models are implemented in PSCAD/EMTDC and evaluated for steady-state operating conditions and for various transients (including balanced and unbalanced low and high voltage ride-through (LVRT and HVRT, respectively)).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
International Electrotechnical Commission, EC 61000-21, Wind turbine generator systems—Part 21: Measurement and assessment of power quality characteristics of grid connected wind turbines. 2001
J. Svensson, M. Lindgren, Influence of nonlinearities on the frequency response of a grid-connected vector-controlled VSC. IEEE Trans. Ind. Electron. 46(2), 319–324 (1999)
N. Bao, Q. Chen, T. Jiang, Modelling and identification of a wind turbine system. Wind Eng. 20(4), 203–218 (1996)
A. Dadone, L. Dambrosio, B. Fortunato, One step ahead adaptive control technique for wind systems. Energy Convers. Manag. 39(5), 399–413 (1998)
Y. Coughlan, P. Smith, A. Mullane, M. O’Malley, Wind turbine modelling for power system stability analysis—a system operator perspective. IEEE Trans. Power Syst. 22(3), 929–936 (2007)
EirGrid, Wind Dynamic Modelling Update. 2014. http://www.eirgrid.com/customers/gridconnections/generatorconnections/winddynamicmodelling/
International Electrotechnical Commission, IEC 61400-27—Electrical simulation models for wind power generation Wind Turbines, 1st edn. 2012
G. Rogdakis, R. Garcia-Valle, I. Arana, Transient model validation of fixed-speed induction generator using wind farm measurements. IEEE Trans. Power Syst. 27(1), 564–571 (2012)
J. Glasdam, J. Hjerrild, L.H. Kocewiak, C.L. Bak, L. Zeni, Comparison of Field Measurements and EMT Simulation Results on a Multi-Level STATCOM for Grid Integration of London Array Wind Farm, in Cigré Paris Session, 2014, p. B4_206_2014
S.K. Chaudhary, R. Teodorescu, P. Rodriguez, P.C. Kjaer, A.M. Gole, Negative sequence current control in wind power plants with VSC-HVDC connection. IEEE Trans. Sustain. Energ. 3(3), 535–544 (2012)
N.P. Strachan, D. Jovcic, Stability of a variable-speed permanent magnet wind generator with weak AC grids. IEEE Trans. Power Delivery 25(4), 2779–2788 (2010)
V. Akhmatov, P.B. Eriksen, A large wind power system in almost island operation—A Danish case study. IEEE Trans. Power Syst. 22(3), 937–943 (2007)
J.N. Nielsen, V. Akhmatov, J. Thisted, E. Grøndahl, P. Egedal, M.N. Frydensbjerg, K.H. Jensen, Modelling and fault-ride-trough tests of Siemens Wind Power 3.6 MW variable-speed wind turbines. Wind Eng. 31(6), 441–452 (2007)
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Glasdam, J.B. (2016). Evaluation of the Time Domain Models of the Wind Turbine Generator and the Power Electronic Grid Simulator. In: Harmonics in Offshore Wind Power Plants. Springer Theses. Springer, Cham. https://doi.org/10.1007/978-3-319-26476-9_9
Download citation
DOI: https://doi.org/10.1007/978-3-319-26476-9_9
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-26475-2
Online ISBN: 978-3-319-26476-9
eBook Packages: EngineeringEngineering (R0)