Skip to main content

Transcatheter Pulmonary Valvulation

  • Chapter
  • First Online:
Surgery of Conotruncal Anomalies

Abstract

Transcatheter Pulmonary Valve Implantation (TPVI) has emerged as an attractive therapeutic option for the treatment of right ventricular outflow tract dysfunction. By 2015, more than 7000 transcatheter pulmonary valve implantation have been performed. Two valves are currently used for TPVI. The Melody Valve (MeV) (Medtronic Inc., Minneapolis, Minnesota), which can be expanded to 22 mm diameter. The Edward Sapien Valve (ESV) (Edwards Lifesciences LLC, Irvine, California), which can be expanded to 26 mm diameter. This chapter summarizes the concept, its evolution in clinical practice, current applications, and the devices in current use. Early and mid-term outcomes are presented as well as projected long term results and future developments.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 249.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 249.00
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Bonhoeffer P, Boudjemline Y, Saliba Z, et al. Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction. Lancet. 2000;356:1403–5.

    Article  CAS  PubMed  Google Scholar 

  2. Khambadkone S, Coats L, Taylor A, et al. Percutaneous pulmonary valve implantation in humans: results in 59 consecutive patients. Circulation. 2005;112:1189–97.

    Article  PubMed  Google Scholar 

  3. Lurz P, Coats L, Khambadkone S, Nordmeyer J, Boudjemline Y, Schievano S, Muthurangu V, Lee TY, Parenzan G, Derrick G, Cullen S, et al. Percutaneous pulmonary valve implantation: impact of evolving technology and learning curve on clinical outcome. Circulation. 2008;117:1964–72.

    Article  PubMed  Google Scholar 

  4. Zahn EM, Hellenbrand WE, Lock JE, McElhinney DB. Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. Clinical trial. J Am Coll Cardiol. 2009;54:1722–9.

    Article  PubMed  Google Scholar 

  5. McElhinney DB, Hellenbrand WE, Zahn EM, et al. Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial. Circulation. 2010;122:507–16.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Eicken A, Ewert P, Hager A, et al. Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients. Eur Heart J. 2011;32:1260–5.

    Article  PubMed  Google Scholar 

  7. Fraisse A, Aldebert P, Malekzadeh-Milani S, Thambo JB, Piéchaud JF, Aucoururier P, Chatelier G, Bonnet D, Iserin L, Bonello B, Assaidi A, Kammache I, Boudjemline Y. Melody transcatheter pulmonary valve implantation: results from a french registry. Arch Cardiovasc Dis. 2014;107:607–14.

    Article  PubMed  Google Scholar 

  8. Butera G, Milanesi O, Spadoni I, et al. Melody transcatheter pulmonary valve implantation. Results from the registry of the Italian Society of Pediatric Cardiology. Catheter Cardiovasc Interv. 2013;81:310–6.

    Article  PubMed  Google Scholar 

  9. Kenny D, Hijazi ZM, Kar S. Percutaneous implantation of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position: early phase 1 results from an international multicenter clinical trial. J Am Coll Cardiol. 2011;58:2248–56.

    Article  PubMed  Google Scholar 

  10. Haas NA, Moysich A, Neudorf U, et al. Percutaneous implantation of the Edwards SAPIEN(™) pulmonic valve: initial results in the first 22 patients. Clin Res Cardiol. 2013;102:119–28.

    Article  PubMed  Google Scholar 

  11. Rubio-Alvarez V, Limon R, Soni J. [Intracardiac valvulotomy by means of a catheter]. Arch Inst Cardiol Mex. 1953;23:183–92.

    CAS  PubMed  Google Scholar 

  12. Kan JS, White Jr RI, Mitchell SE, Gardner TJ. Percutaneous balloon valvuloplasty: a new method for treating congenital pulmonary-valve stenosis. N Engl J Med. 1982;307:540–2.

    Article  CAS  PubMed  Google Scholar 

  13. Zeevi B, Keane JF, Perry SB, et al. Balloon dilation of postoperative right ventricular outflow obstructions. J Am Coll Cardiol. 1989;14:401–8.

    Article  CAS  PubMed  Google Scholar 

  14. Almagor Y, Prevosti LG, Bartorelli AL, et al. Balloon expandable stent implantation in stenotic right heart valved conduits. J Am Coll Cardiol. 1990;16:1310–4.

    Article  CAS  PubMed  Google Scholar 

  15. Ovaert C, Caldarone CA, McCrindle BW, et al. Endovascular stent implantation for the management of postoperative right ventricular outflow tract obstruction: clinical efficacy. J Thorac Cardiovasc Surg. 1999;118:886–93.

    Article  CAS  PubMed  Google Scholar 

  16. Sugiyama H, Williams W, Benson LN. Implantation of endovascular stents for the obstructive right ventricular outflow tract. Heart. 2005;91:1058–63.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  17. McElhinney DB, Hennesen JT. The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement. Ann N Y Acad Sci. 2013;1291:77–85.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. Garay F, Webb J, Hijazi ZM. Percutaneous replacement of pulmonary valve using the Edwards-Cribier percutaneous heart valve: first report in a human patient. Catheter Cardiovasc Interv. 2006;67:659–62.

    Article  PubMed  Google Scholar 

  19. Cheatham SL, Holzer RJ, Chisolm JL, Cheatham JP. The Medtronic Melody® transcatheter pulmonary valve implanted at 24-mm diameter – it works. Catheter Cardiovasc Interv. 2013;82:816–23.

    Article  PubMed  Google Scholar 

  20. Boone RH, Webb JG, Horlick E, et al. Transcatheter pulmonary valve implantation using the Edwards SAPIENTM transcatheter heart valve. Catheter Cardiovasc Interv. 2010;75:286–94.

    Article  PubMed  Google Scholar 

  21. Feltes TF, Bacha E, Beekman RH, et al. Indications for cardiac catheterization & and intervention in pediatric cardiac disease. Circulation. 2011;123:2607–52.

    Article  PubMed  Google Scholar 

  22. Gillespie MJ, Rome JJ, Levi DS. Melody valve implant within failed bioprosthetic valves in the pulmonary position: a multicenter experience. Circ Cardiovasc Interv. 2012;5:862–70.

    Article  PubMed  Google Scholar 

  23. Meadows JJ, Moore PM, Berman DP. Use and performance of the melody transcatheter pulmonary valve in native and postsurgical, nonconduit right ventricular outflow tracts. Circ Cardiovasc Interv. 2014;7:374–80.

    Article  PubMed  Google Scholar 

  24. Malekzadeh-Milani S, Ladouceur M, Cohen S, Iserin L, Boudjemline Y. Results of transcatheter pulmonary valvulation in native or patched right ventricular outflow tracts. Arch Cardiovasc Dis. 2014;107:592–8.

    Article  PubMed  Google Scholar 

  25. Berman DP, McElhinney DB, Vincent JA, Hillenbrand WE, Zahn EM. Feasibility and short-term outcomes of percutaneous transcatheter pulmonary valve replacement in small (<30 kg) children with dysfunctional right ventricular outflow tract conduits. Circ Cardiovasc Interv. 2014;7:142–8.

    Article  PubMed  Google Scholar 

  26. Schievano S, Coats L, Migliavacca F, et al. Variations in right ventricular outflow tract morphology following repair of congenital heart disease: implications for percutaneous pulmonary valve implantation. J Cardiovasc Magn Reson. 2007;9:687–95.

    Article  PubMed  Google Scholar 

  27. Boudjemline Y, Agnoletti G, Bonnet D, et al. Percutaneous pulmonary valve replacement in a large right ventricular outflow tract: an experimental study. J Am Coll Cordial. 2004;43:1082–7.

    Article  Google Scholar 

  28. Boudjemline Y, Brugada G, Van-Aerschot I. Outcomes and safety of transcatheter pulmonary valve replacement in patients with large patched right ventricular outflow tracts. Arch Cardiovasc Dis. 2012;105:404–13.

    Article  PubMed  Google Scholar 

  29. Fraisse A, Assaidi A, Mauri L, et al. Coronary artery compression during intention to treat right ventricle outflow with percutaneous pulmonary valve implantation: Incidence, diagnosis and outcome. Catheter Cardiovasc Interv. 2014;83:E260–8.

    Article  PubMed  Google Scholar 

  30. Morray BH, McElhinney DB, Cheatham JP, et al. Risk of coronary artery compression among patients referred for transcatheter pulmonary valve implantation: a multicenter experience. Circ Cardiovasc Interv. 2013;6:535–42.

    Article  PubMed  Google Scholar 

  31. Daskalopoulos DA, Edwards WD, Driscoll DJ, Danielson GK, Puga FJ. Coronary artery compression with fatal myocardial ischemia. J Thorac Cardiovasc Surg. 1983;85:546–51.

    CAS  PubMed  Google Scholar 

  32. Lurz P, Puranik R, Nordmeyer J, et al. Improvement in left ventricular filling properties after relief of right ventricle to pulmonary artery conduit obstruction: contribution of septal motion and interventricular mechanical delay. Eur Heart J. 2009;30:2266–74.

    Article  PubMed  Google Scholar 

  33. Schievano S, Taylor AM, Capelli C, et al. First-in-man implantation of a novel percutaneous valve: a new approach to medical device development. EuroIntervention. 2010;5:745–50.

    Article  PubMed  Google Scholar 

  34. Cao QL, Kenny D, Zhou D, Pan W, Ge J, Hijazi ZM. Early experience with a novel self-expanding percutaneous stent-valve in the native right ventricular outflow tract. Catheter Cardiovasc Interv. 2014;84:1131–7.

    Article  PubMed  Google Scholar 

  35. Demkow M, Rużyłło W, Biernacka EK, et al. Percutaneous Edwards SAPIEN(™) valve implantation for significant pulmonary regurgitation after previous surgical repair with a right ventricular outflow patch. Catheter Cardiovasc Interv. 2014;83:474–81.

    Article  PubMed  Google Scholar 

  36. Nordmeyer J, Khambadkone S, Coats L, et al. Risk stratification, systematic classification, and anticipatory management strategies for stent fracture after percutaneous pulmonary valve implantation. Circulation. 2007;115:1392–7.

    Article  PubMed  Google Scholar 

  37. McElhinney DB, Cheatham JP, Jones TK, et al. Stent fracture, valve failure, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US melody valve trial. Circ Cardiovasc Interv. 2011;4:602–14.

    Article  PubMed  Google Scholar 

  38. Nordmeyer J, Lurz P, Khambadkone S, et al. Prestenting with a bare metal stent before percutaneous pulmonary valve implantation: acute and 1-year outcomes. Heart. 2011;97:118–23.

    Article  PubMed  Google Scholar 

  39. Balzer DT. Percutaneous pulmonary valve implantation: fixing the problems and pushing the envelope. Curr Opin Pediatr. 2012;24:565–8.

    Article  PubMed  Google Scholar 

  40. Nordmeyer J, Coats L, Lurz P, et al. Percutaneous pulmonary valve-in-valve implantation: a successful treatment concept for early device failure. Eur Heart J. 2008;29:810–5.

    Article  PubMed  Google Scholar 

  41. Atamanyuk I, Raja SG, Kostolny M. Bartonella Henselae endocarditis of percutaneously implanted pulmonary valve: a case report. J Heart Valve Dis. 2011;20:94–7.

    PubMed  Google Scholar 

  42. Patel M, Iserin L, Bonnet D, Boudjemline Y. Atypical malignant late infective endocarditis of Melody valve. J Thorac Cardiovasc Surg. 2012;143:e32–5.

    Article  PubMed  Google Scholar 

  43. Alsoufi B, Al-joufan M, Al-Omrani A, Bulbul Z. Obstruction of a percutaneous pulmonary valve by an aspergillus mycotic thrombus mimicking massive pulmonary embolus. Ann Thorac Surg. 2012;94:e5–6.

    Article  PubMed  Google Scholar 

  44. Bhat D, Forbes TJ, Aggarwal S. A case of life-threatening Staphylococcus aureus endocarditis involving percutaneous transcatheter prosthetic pulmonary valve. Congenit Heart Dis. 2013;8:E161–4.

    Article  PubMed  Google Scholar 

  45. Buber J, Bergersen L, Lock JE. Bloodstream infections occurring in patients with percutaneously implanted bio-prosthetic pulmonary valve: a single-center experience. Circ Cardiovasc Interv. 2013;6:301–10.

    Article  PubMed  Google Scholar 

  46. McElhinney D, Benson L, Eicken A, Kreutzer J, Padera RF, Zahn EM. Infective endocarditis after transcatheter pulmonary valve replacement using the melody valve: combined results of 3 prospective North American and European Studies. Circ Cardiovasc Interv. 2013;6:292–300.

    Article  PubMed  Google Scholar 

  47. Villafañe J, Baker GH, Austin EH, Miller S, Peng L, Beekman R. Melody® pulmonary valve bacterial endocarditis: experience in four pediatric patients and a review of the literature. Catheter Cardiovasc Interv. 2014;84:212–8.

    Article  PubMed  Google Scholar 

  48. Tiete AR, Sachweh S, Roemer U, Kozlik-Fredmann R, Reuchart B, Daebritz SH. Right ventricular outflow tract reconstruction with the Contegra bovine jugular vein conduit: a word of caution. Ann Thorac Surg. 2004;77:2151–6.

    Article  PubMed  Google Scholar 

  49. Shebani SO, McGuirk S, Baghai M, et al. Right ventricular outflow tract reconstruction using Contegra valved conduit: natural history and conduit performance under pressure. Eur J Cardiothorac Surg. 2006;29:397–405.

    Article  PubMed  Google Scholar 

  50. Baslaim G. Bovine valved xenograft (Contegra) conduit in the extracardiac Fontan procedure: the preliminary experience. J Card Surg. 2008;23:146–9.

    Article  PubMed  Google Scholar 

  51. Bajraktari G, Olloni R, Daullxhiu I, Ademaj F, Vela Z, Pajaziti M. MRSA endocarditis of bovine Contegra valved conduit: a case report. Cases J. 2009;2:57.

    Article  PubMed  PubMed Central  Google Scholar 

  52. Stefanidis C, Benahmed-Mostafa A, Sanoussi A, Quiriny M, Demanet H, Theunissen C, et al. Edocarditis of bovine jugular vein conduit due to Q fever. Ann Thorac Surg. 2011;91:1990–2.

    Article  PubMed  Google Scholar 

  53. Prior N, Alphonso N, Arnold P, et al. Bovine jugular vein valved conduit: up to 10 years follow-up. J Thorac Cardiovasc Surg. 2011;141:983–7.

    Article  PubMed  Google Scholar 

  54. Breymann T, Blanz U, Wojtalik M, et al. European Contegra Multicenter Study: 7-year results after valved bovine jugular vein graft implantations. Thorac Cardiovasc Surg. 2009;57:257–69.

    Article  CAS  PubMed  Google Scholar 

  55. Albanesi F, Sekarski N, Lambrou D, Von Segesser LK, Berdajs DA. Incidence and risk factors for Contegra graft infection following right ventricular outflow tract reconstruction: long-term results. Eur J Cardiothorac Surg. 2014;45:1070–4.

    Article  PubMed  Google Scholar 

  56. Cheung G, Vejlstrup N, Ihlemann N, et al. Infective endocarditis following percutaneous pulmonary valve replacement: diagnostic challenges and application of intra-cardiac echocardiography. Int J Cardiol. 2013;169:425–9.

    Article  PubMed  Google Scholar 

  57. Lee C, Park CS, Lee CH. Durability of bioprosthetic valves in the pulmonary position: long-term follow-up of 181 implants in patients with congenital heart disease. Cardiovasc Surg. 2011;142:351–8.

    Google Scholar 

  58. Murphy JG, Gersh BJ, Mair DD, et al. Long-term outcome in patients undergoing surgical repair of tetralogy of Fallot. N Engl J Med. 1993;329:593–9.

    Article  CAS  PubMed  Google Scholar 

  59. Gatzoulis MA, Till JA, Somerville J, Redington AN. Mechanoelectrical interaction in tetralogy of Fallot. QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmias and sudden death. Circulation. 1995;92:231–7.

    Article  CAS  PubMed  Google Scholar 

  60. Plymen CM, Bolger AP, Lurz P, et al. Electrical remodeling following percutaneous pulmonary valve implantation. Am J Cardiol. 2011;107:309–14.

    Article  PubMed  Google Scholar 

  61. Therrien J, Siu S, Harris L, et al. Impact of pulmonary valve replacement on arrhythmia propensity late after repair of tetralogy of Fallot. Circulation. 2001;103:2489–94.

    Article  CAS  PubMed  Google Scholar 

  62. Lurz P, Giardini A, TayloR AM, et al. Effect of altering pathologic right ventricular loading conditions by percutaneous pulmonary valve implantation on exercise capacity. Am J Cardiol. 2010;105:721–6.

    Article  PubMed  Google Scholar 

  63. Diller GP, Kempny A, Liodakis E, et al. Left ventricular longitudinal function predicts life-threatening ventricular arrhythmia and death in adults with repaired tetralogy of Fallot. Circulation. 2012;125:2440–6.

    Article  PubMed  Google Scholar 

  64. Ortega M, Triedman JK, Geva T, et al. Relation of left ventricular dyssynchrony measured by cardiac magnetic resonance tissue tracking in repaired tetralogy of fallot to ventricular tachycardia and death. Am J Cardiol. 2011;107:1535–40.

    Article  PubMed  Google Scholar 

  65. Harrild DM, Marcus E, Hasan B, et al. Impact of transcatheter pulmonary valve replacement on biventricular strain and synchrony assessed by cardiac magnetic resonance feature tracking. Circ Cardiovasc Interv. 2013;6:680–7.

    Article  PubMed  Google Scholar 

  66. Eyskens B, Reybrouck T, Bogaert J, et al. Homograft insertion for pulmonary regurgitation after repair of tetralogy of Fallot improves cardiorespiratory exercise performance. Am J Cardiol. 2000;85:221–5.

    Article  CAS  PubMed  Google Scholar 

  67. Müller J, Engelhardt A, Fratz S, Eicken A, Ewert P, Hager A. Improved exercise performance and quality of life after percutaneous pulmonary valve implantation. Int J Cardiol. 2014;173:388–92.

    Article  PubMed  Google Scholar 

  68. Batra AS, McElhinney DB, Wang W, et al. Cardiopulmonary exercise function among patients undergoing transcatheter pulmonary valve implantation in the US Melody valve investigational trial. Am Heart J. 2012;163:280–7.

    Article  PubMed  Google Scholar 

  69. Lutter G, Metzner A, Jahnke T, Bombien R, Boldt J, Iino K, Cremer J, Stock UA. Percutaneous tissue-engineered pulmonary valved stent implantation. Ann Thorac Surg. 2010;89:259–63.

    Article  PubMed  Google Scholar 

  70. Boldt J, Lutter G, Pohanke J, Fischer G, Schoettler J, Cremer J, Metzner A. Percutaneous tissue-engineered pulmonary valved stent implantation: comparison of bone marrow-derived CD133+-cells and cells obtained from carotid artery. Tissue Eng Part C Methods. 2013;19:363–74.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alain Fraisse MD, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Trivedi, K.R., Oswal, N., Fraisse, A. (2016). Transcatheter Pulmonary Valvulation. In: Lacour-Gayet, F., Bove, E., Hraška, V., Morell, V., Spray, T. (eds) Surgery of Conotruncal Anomalies. Springer, Cham. https://doi.org/10.1007/978-3-319-23057-3_13

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-23057-3_13

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-23056-6

  • Online ISBN: 978-3-319-23057-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics