Monitoring Accuracy of Home Mechanical Ventilators: Key Technical Elements and Clinical Implications

  • Chapter
Noninvasive Mechanical Ventilation

Abstract

The monitoring of home noninvasive ventilation by built-in software should accurately reflect the amount of gas entering into the patient’s airways. For this purpose, the native curves should be transformed through mathematical algorithms designed for and adapted to the configuration of different tubing, the expiratory system, and the physical phenomena that can occur in clinical practice.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Abbreviations

CPAP:

Continuous positive airway pressure

ICU:

Intensive care unit

IPAP:

Inspiratory positive airway pressure

NIV:

Noninvasive ventilation.

References

  1. Contal O, Vignaux L, Combescure C, Pepin JL, Jolliet P, Janssens JP. Monitoring of non-invasive ventilation by built-in software of home bi-level ventilators: a bench study. Chest. 2012;141:469–76.

    Article  PubMed  Google Scholar 

  2. Janssens JP, Borel JC, Pepin JL, SomnoNIV Group. Nocturnal monitoring of home noninvasive ventilation: the contribution of simple tools such as pulse oximetry, capnography, built-in ventilator software and autonomic markers of sleep fragmentation. Thorax. 2011;66:438–45.

    Article  PubMed  Google Scholar 

  3. Luján M, Sogo A, Pomares X, Monsó E, Sales B, Blanch L. Effect of leak and breathing pattern on the accuracy of tidal volume estimation. Respir Care. 2013;58(5):770–7.

    Article  PubMed  Google Scholar 

  4. Oliveri C, Costa R, Conti G, Navalesi P. Bench studies evaluating devices for non-invasive ventilation: critical analysis and future perspectives. Intensive Care Med. 2012;38:160–7.

    Article  Google Scholar 

  5. Sogo A, Montanyà J, Monsó E, Blanch L, Pomares X, Lujàn M. Effect of dynamic random leaks on the monitoring accuracy of home mechanical ventilators: a bench study. BMC Pulm Med. 2013;13:75.

    Article  PubMed Central  PubMed  Google Scholar 

  6. Luján M, Sogo A, Grimau C, Pomares X, Blanch L, Monsó E. Influence of dynamic leaks in volume-targeted pressure support noninvasive ventilation: a bench study. Respir Care. 2015;60(2):191–200.

    Article  PubMed  Google Scholar 

  7. Bachiller PR, McDonough JM, Feldman JM. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Anesth Analg. 2008;106:1392–400.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Manel Luján MD, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Luján, M., Pomares, X., Sogo, A. (2016). Monitoring Accuracy of Home Mechanical Ventilators: Key Technical Elements and Clinical Implications. In: Esquinas, A. (eds) Noninvasive Mechanical Ventilation. Springer, Cham. https://doi.org/10.1007/978-3-319-21653-9_18

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-21653-9_18

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-21652-2

  • Online ISBN: 978-3-319-21653-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics