Abstract
Biomechanics is the study of the structure and function of biological systems by means of mechanics. Functional mandibular movement is defined as all the normal, proper, or characteristic of three-dimensional movements of the mandible during speech, mastication, swallowing, and other associated movements. Most functional movement occurs during mastication and speech. A removable partial denture (RPD) is not rigidly attached to the teeth, and therefore there is a potential for movement of the denture when these functional movements create forces on the teeth and denture. The practitioner should begin with the understanding of how these three-dimensional functional forces (mechanics) act on the biological environment (abutment teeth, residual ridges, and alveolar mucosa). During treatment planning of the RPD, the clinician must consider the biomechanics of the RPD as well as the patient’s comfort, esthetics, and prognosis of the abutments to withstand the forces.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Bibliography
Akaltan F, Kaynak D. An evaluation of the effects of two distal extension removable partial denture designs on tooth stabilization and periodontal health. J Oral Rehabil. 2005;32:823–9.
Aridome K, Yamazaki M, Baba K, Ohyama T. Bending properties of strengthened Ti-6Al-7Nb alloy major connectors compared to Co-Cr alloy major connectors. J Prosthet Dent. 2005;93:267–73.
Berg T, Caputo AA. Maxillary distal-extension removable partial denture abutments with reduced periodontal support. J Prosthet Dent. 1993;70:245–50.
Bohnenkamp DM. Removable partial dentures: clinical concepts. Dent Clin North Am. 2014;58:69–89.
Budtz-Jorgensen E, Bochet G. Alternate framework designs for removable partial dentures. J Prosthet Dent. 1998;80:58–66.
Carr AB, Brown DT. McCracken’s removable partial prosthodontics. 12th ed. St. Louis: Elsevier Mosby; 2011.
Chou TM, Caputo AA, Moore DJ, Xiao B. Photoelastic analysis and comparison of force-transmission characteristics of intracoronal attachments with clasp distal-extension removable partial dentures. J Prosthet Dent. 1989;62:313–9.
Chou TM, Eick JD, Moore DJ, Tira DE. Stereophotogrammetric analysis of abutment tooth movement in distal-extension removable partial dentures with intracoronal attachments and clasps. J Prosthet Dent. 1991;66:343–9.
de Freitas RF, de Carvalho Dias K, da Fonte Porto Carreiro A, Barbosa GA, Ferreira MA. Mandibular implant-supported removable partial denture with distal extension: a systematic review. J Oral Rehabil. 2012;39:791–8.
DeBoer J. The effects on function of distal-extension removable partial dentures as determined by occlusal rest position. J Prosthet Dent. 1988;60:693–6.
Grossmann Y, Nissan J, Levin L. Clinical effectiveness of implant-supported removable partial dentures: a review of the literature and retrospective case evaluation. J Oral Maxillofac Surg. 2009;67:1941–6.
Hosman HJ. Influence of clasp design of distal extension removable partial dentures on the periodontium of the abutment teeth. Int J Prosthodont. 1990;3:256–65.
Igarashi Y, Ogata A, Kuroiwa A, Wang CH. Stress distribution and abutment tooth mobility of distal-extension removable partial dentures with different retainers: an in vivo study. J Oral Rehabil. 1999;26:111–6.
Itoh H, Caputo AA, Wylie R, Berg T. Effects of periodontal support and fixed splinting on load transfer by removable partial dentures. J Prosthet Dent. 1998;79:465–71.
Itoh H, Baba K, Aridome K, Okada D, Tokuda A, Nishiyama A, Miura H, Igarashi Y. Effect of direct retainer and major connector designs on RPD and abutment tooth movement dynamics. J Oral Rehabil. 2008;35:810–5.
Jiao T, Chang T, Caputo AA. Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components. Aust Dent J. 2009;54:31–7.
Jorge JH, Giampaolo ET, Vergani CE, Machado AL, Pavarina AC, Cardoso de Oliveira MR. Clinical evaluation of abutment teeth of removable partial denture by means of the Periotest method. J Oral Rehabil. 2007;34:222–7.
Kapur KK, Deupree R, Dent RJ, Hasse AL. A randomized clinical trial of two basic removable partial denture designs. Part I: comparisons of five-year success rates and periodontal health. J Prosthet Dent. 1994;72:268–82.
Kawata T, Kawaguchi T, Yoda N, Ogawa T, Kuriyagawa T, Sasaki K. Effects of a removable partial denture and its rest location on the forces exerted on an abutment tooth in vivo. Int J Prosthodont. 2008;21:50–2.
Kono K, Kurihara D, Suzuki Y, Ohkubo C. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments. J Prosthodont Res. 2014;58:115–20.
Lee HE, Wu JH, Wang CH, Lan TH, Du JE. Biomechanical analysis of distal extension removable partial dentures with different retainers. J Dent Sci. 2008;3:133–9.
Leupold RJ, Flinton RJ, Pfeifer DL. Comparison of vertical movement occurring during loading of distal-extension removable partial denture bases made by three impression techniques. J Prosthet Dent. 1992;68:290–3.
Ogata K, Miyake T, Okunishi M. Longitudinal study on occlusal force distribution in lower distal-extension removable partial dentures with circumferential clasps. J Oral Rehabil. 1992;19:585–94.
Petridis H, Hempton TJ. Periodontal considerations in removable partial denture treatment: a review of the literature. Int J Prosthodont. 2001a;14:164–72.
Petridis H, Hempton TJ. Periodontal considerations in removable partial denture treatment: a review of the literature. Int J Prosthodont. 2001b;14:164–72.
Phoenix RD, Cagna DR, Defreest CF. Stewart’s clinical removable partial prosthodontics. 4th ed. Hanover Park: Quintessence Publishing; 2008.
Sahin V, Akaltan F, Parnas L. Effects of the type and rigidity of the retainer and the number of abutting teeth on stress distribution of telescopic-retained removable partial dentures. J Dent Sci. 2012;7:7–13.
Sato M, Suzuki Y, Kurihara D, Shimpo H, Ohkubo C. Effect of implant support on mandibular distal extension removable partial dentures: relationship between denture supporting area and stress distribution. J Prosthodont Res. 2013;57:109–12.
Taylor DT, Pflughoeft FA, McGivney GP. Effect of two clasping assemblies on arch integrity as modified by base adaptation. J Prosthet Dent. 1982;47:120–5.
Tebrock OC, Rohen RM, Fenster RK, Pelleu Jr GB. The effect of various clasping systems on the mobility of abutment teeth for distal-extension removable partial dentures. J Prosthet Dent. 1979;41:511–6.
The glossary of prosthetic terms. J Prosthet Dent. 2005;94:10–92.
Wismeijer D, Tawse-Smith A, Payne AG. Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: patient satisfaction. Clin Oral Implants Res. 2013;24:20–7.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Bural, C. (2016). Biomechanics of Removable Partial Dentures. In: Şakar, O. (eds) Removable Partial Dentures. Springer, Cham. https://doi.org/10.1007/978-3-319-20556-4_4
Download citation
DOI: https://doi.org/10.1007/978-3-319-20556-4_4
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-20555-7
Online ISBN: 978-3-319-20556-4
eBook Packages: MedicineMedicine (R0)