Abstract
The non-linear optical effect known as second harmonic generation (SHG) has been recognized since the earliest days of the laser. But it has only been in the last 20 years that it has begun to emerge as a viable microscope imaging contrast mechanism for visualization of cell and tissue structure and function. This is because only small modifications are required to equip a standard laser scanning 2-photon microscope for second harmonic imaging microscopy (SHIM). SHG signals from certain membrane-bound dyes are highly sensitive to membrane potential, indicating that SHIM may become a valuable probe of cell physiology. However, for the current generation of dyes and microscopes, the small signal size limits the number of photons that can be collected during the course of a fast action potential. Better dyes and optimized microscope optics could ultimately lead to the ability to image neuronal electrical activity with SHIM.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Araya R, Jiang J, Eisenthal KB, Yuste R (2006) The spine neck filters membrane potentials. Proc Natl Acad Sci U S A 103:17961–17966
Araya R, Nikolenko V, Eisenthal KB, Yuste R (2007) Sodium channels amplify spine potentials. Proc Natl Acad Sci U S A 104:12347–12352
Ben-Oren I, Peleg G, Lewis A, Minke B, Loew LM (1996) Infrared nonlinear optical measurements of membrane potential in photoreceptor cells. Biophys J 71:1616–1620
Bianchini P, Diaspro A (2008) Three-dimensional (3D) backward and forward second harmonic generation (SHG) microscopy of biological tissues. J Biophotonics 1:443–450
Bouevitch O, Lewis A, Pinevsky I, Wuskell JP, Loew LM (1993) Probing membrane potential with non-linear optics. Biophys J 65:672–679
Campagnola P, Loew LM (2003) Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms. Nat Biotechnol 21:1356–1360
Campagnola PJ, Clark HA, Mohler WA, Lewis A, Loew LM (2001) Second harmonic imaging microscopy of living cells. J Biomed Opt 6:277–286
Campagnola PJ, Wei M-d, Lewis A, Loew LM (1999) High resolution optical imaging of live cells by second harmonic generation. Biophys J 77:3341–3349
Clark HA, Campagnola PJ, Wuskell JP, Lewis A, Loew LM (2000) Second harmonic generation properties of fluorescent polymer encapsulated gold nanoparticles. J Am Chem Soc 122:10234–10235
Cole JM, Kreiling S (2002) Exploiting structure/property relationships in organic non-linear optical materials: developing strategies to realize the potential of TCNQ derivatives. CrystEngComm 4:232–238
Conboy JC, Richmond GL (1997) Examination of the electrochemical interface between two immiscible electrolye solutions by second harmonic generation. J Phys Chem B 101:983–990
Denk W, Strickler JH, Webb WW (1990) Two-photon laser scanning fluorescence microscopy. Science 248:73–76
Dirk CW, Twieg RJ, Wagniere J (1986) The Contribution of Pi Electrons to Second Harmonic Generation in Organic Molecule. J Am Chem Soc 108:5387–5395
Dombeck DA, Blanchard-Desce M, Webb WW (2004) Optical recording of action potentials with second-harmonic generation microscopy. J Neurosci 24:999–1003
Dombeck DA, Sacconi L, Blanchard-Desce M, Webb WW (2005) Optical recording of fast neuronal membrane potential transients in acute mammalian brain slices by second-harmonic generation microscopy. J Neurophysiol 94:3628–3636
Fluhler E, Burnham VG, Loew LM (1985) Spectra, membrane binding and potentiometric responses of new charge shift probes. Biochemistry 24:5749–5755
Freund I, Deutsch M, Sprecher A (1986) Connective tissue polarity. Optical second-harmonic microscopy, crossed-beam summation, and small-angle scattering in rat-tail tendon. Biophys J 50:693–712
Huang J, Lewis A (1989) Determination of the absolute orientation of the retinyldiene chromophore in purple membrane by a second harmonic interference technique. Biophys J 55:835–842
Huang JY, Lewis A, Loew LM (1988) Non-linear optical properties of potential sensitive styryl dyes. Biophys J 53:665–670
Jiang J, Eisenthal KB, Yuste R (2007) Second harmonic generation in neurons: electro-optic mechanism of membrane potential sensitivity. Biophys J 93:L26–L28
Millard AC, Campagnola PJ, Mohler W, Lewis A, Loew LM (2003a) Second harmonic imaging microscopy. In: Marriott G, Parker I (eds) Methods in enzymology, vol. 361B. Academic, San Diego, pp 47–69
Millard AC, Jin L, Lewis A, Loew LM (2003b) Direct measurement of the voltage sensitivity of second-harmonic generation from a membrane dye in patch-clamped cells. Opt Lett 28:1221–1223
Millard AC, Jin L, Wei M-d, Wuskell JP, Lewis A, Loew LM (2004) Sensitivity of second harmonic generation from styryl dyes to trans-membrane potential. Biophys J 86:1169–1176
Millard AC, Jin L, Wuskell JP, Boudreau DM, Lewis A, Loew LM (2005a) Wavelength- and time-dependence of potentiometric non-linear optical signals from styryl dyes. J Membr Biol 208:103–111
Millard AC, Lewis A, Loew LM (2005b) Second harmonic imaging of membrane potential. In: Yuste R, Konnerth A (eds) Imaging in neuroscience and development. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, pp 463–474
Mohler W, Millard AC, Campagnola PJ (2003) Second harmonic generation imaging of endogenous structural proteins. Methods 29:97–109
Moreaux L, Pons T, Dambrin V, Blanchard-Desce M, Mertz J (2003) Electro-optic response of second-harmonic generation membrane potential sensors. Opt Lett 28:625–627
Moreaux L, Sandre O, Blanchard-desce M, Mertz J (2000a) Membrane imaging by simultaneous second-harmonic generation and two-photo microscopy. Opt Lett 25:320–322
Moreaux L, Sandre O, Mertz J (2000b) Membrane imaging by second harmonic generation microscopy. J Opt Soc Am B 17:1685–1694
Morley JO (1988) Non-linear optical properties of organic molecules. 7. Calculated hyperpolarizabilities of azulenes and sesquifulvalene. J Am Chem Soc 110:7660–7663
Nemet BA, Nikolenko V, Yuste R (2004) Second harmonic imaging of membrane potential of neurons with retinal. J Biomed Opt 9:873–881
Nicoud JF, Twieg RJ (1987) Design and synthesis of organic molecular compounds for efficient second-harmonic generation. In: Chemla DS, Zyss J (eds) Nonlinear optical properties of organic molecules and crystals, vol. 1. Academic, Orlando, pp 227–296
Nuriya M, Jiang J, Nemet B, Eisenthal KB, Yuste R (2006) Imaging membrane potential in dendritic spines. Proc Natl Acad Sci U S A 103:786–790
Nuriya M, Yasui M (2010) Membrane potential dynamics of axons in cultured hippocampal neurons probed by second-harmonic-generation imaging. J Biomed Opt 15:020503
Pons T, Moreaux L, Mongin O, Blanchard-Desce M, Mertz J (2003) Mechanisms of membrane potential sensing with second-harmonic generation microscopy. J Biomed Opt 8:428–431
Rama S, Vetrivel L, Semyanov A (2010) Second-harmonic generation voltage imaging at subcellular resolution in rat hippocampal slices. J Biophotonics 3:784–790
Sacconi L, Dombeck DA, Webb WW (2006) Overcoming photodamage in second-harmonic generation microscopy: real-time optical recording of neuronal action potentials. Proc Natl Acad Sci U S A 103:3124–3129
Sheppard C, Kompfner R, Gannaway J, Walsh D (1977) IEEE J Quant Electron 13D:100E
Teisseyre TZ, Millard AC, Yan P, Wuskell JP, Wei M-d, Lewis A, Loew LM (2007) Non-linear optical potentiometric dyes optimized for imaging with 1064 nm light. J Biomed Opt 12:044001–044008
Theer P, Denk W, Sheves M, Lewis A, Detwiler PB (2011) Second-harmonic generation imaging of membrane potential with retinal analogues. Biophys J 100:232–242
Williams DJ (1984) Organic polymeric and non-polymeric materials with large optical non-linearities. Angew Chem Int Ed Engl 23:690–703
Wilson SA, Millard A, Lewis A, Loew LM (2014) Monitoring membrane potential with second-harmonic generation. Cold Spring Harb Protoc 2014:643–654
Yan ECY, Liu Y, Eisenthal KB (1998) New method for determination of surface potential of microscopic particles by second harmonic generation. J Phys Chem B 102:6331–6336
Yan P, Millard AC, Wei M, Loew LM (2006) Unique contrast patterns from resonance-enhanced chiral SHG of cell membranes. J Am Chem Soc 128:11030–11031
Yan P, Xie A, Wei M-d, Loew LM (2008) Amino(oligo)thiophene-based environmentally sensitive biomembrane chromophores. J Org Chem 73:6587–6594
Zhou W-L, Yan P, Wuskell JP, Loew LM, Antic SD (2007) Intracellular long wavelength voltage-sensitive dyes for studying the dynamics of action potentials in axons and thin dendrites. J Neurosci Methods 164:225–239
Acknowledgment
We are indebted to the many talented students and colleagues who have participated in the development of SHG imaging in our laboratories over the last 20 years. This work was supported by NIH EB001963.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Loew, L.M., Lewis, A. (2015). Second Harmonic Imaging of Membrane Potential. In: Canepari, M., Zecevic, D., Bernus, O. (eds) Membrane Potential Imaging in the Nervous System and Heart. Advances in Experimental Medicine and Biology, vol 859. Springer, Cham. https://doi.org/10.1007/978-3-319-17641-3_19
Download citation
DOI: https://doi.org/10.1007/978-3-319-17641-3_19
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-17640-6
Online ISBN: 978-3-319-17641-3
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)