Abstract
The article presents the problem of the Zener diode based reference voltage sources resistance to changes in operating temperature. The test stand, measurement methodology and results are presented. Reference voltage sources are crucial elements of analog-to-digital systems. They set the standard to which the measured voltage is compared to. Therefore, the stability of their work is critical for many areas of precision metrology.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Harrison, L.T.: Current sources and voltage references. Elsevier Inc. (2005)
MAX 6325 datasheet provided by Maxim Integrated
Kerlin, T.W., Johnson, M.: Practical Thermocouple Thermometry, 2nd edn. Research Triangle Park, ISA (2012)
Nowak, P., et al.: Resistance of MAX 6325 Reference Voltage Source on Supply Voltage Variation. In: Mechatronics-Ideas for Industrial Application, pp. 337–344. Springer International Publishing (2015)
Nowak, P., Juś, A., Szewczyk, R., Pijarski, R., Nowicki, M., Winiarski, W.: Test Stand for Temperature Characteristics of Ultra-Precise Resistors. In: Awrejcewicz, J., Szewczyk, R., Trojnacki, M., Kaliczyńska, M. (eds.) Mechatronics: Ideas for Industrial Applications. AISC, vol. 317, pp. 345–352. Springer, Heidelberg (2015)
Horowitz, P., Hill, P.: The art of electronics, 2nd edn. Cambridge University Press, Cambridge (1989)
Dobosz, M.: Wspomagana komputerowo statystyczna analiza wyników badań, EXIT (2004)
Korytkowski, J.: Monolityczne układy konwerterów sigma-delta do pomiaru wartości skutecznej napięcia i ich porównanie ze scalonymi konwerterami klasycznymi. Pomiary, Automatyka, Robotyka 16, 84–89 (2012)
Korytkowski, J.: Układ elektroniczny cyfrowej syntezy rezystancji do dokładnej symulacji rezystancyjnych czujników temperatury. Pomiary Automatyka Robotyka 5, 86–92 (2013)
Warsza, Z.L.: New approach to the accuracy description of unbalanced bridge circuits with the example of Pt sensor resistance bridges. Journal of Automation Mobile Robotics and Intelligent Systems 4, 8–15 (2010)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this paper
Cite this paper
Nowak, P., Juś, A., Szewczyk, R. (2015). Resistance of MAX 6325 Reference Voltage Source on Operating Temperature Variation. In: Szewczyk, R., Zieliński, C., Kaliczyńska, M. (eds) Progress in Automation, Robotics and Measuring Techniques. Advances in Intelligent Systems and Computing, vol 352. Springer, Cham. https://doi.org/10.1007/978-3-319-15835-8_21
Download citation
DOI: https://doi.org/10.1007/978-3-319-15835-8_21
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-15834-1
Online ISBN: 978-3-319-15835-8
eBook Packages: EngineeringEngineering (R0)