Abstract
High resolution 4D (3D+time) cerebral CT perfusion (CTP) scans can be used to create 3D arteriograms (showing only arteries) and venograms (only veins). However, due to the low X-ray radiation dose used for acquiring the CTP scans, they are inherently noisy. In this paper, we propose a time intensity profile similarity (TIPS) anisotropic diffusion method that uses the 4th dimension to distinguish between structures, for reducing noise and enhancing arteries and veins in 4D CTP scans. The method was evaluated on 20 patient CTP scans. An observer study was performed by two radiologists, assessing the arteries and veins in arteriograms and venograms derived from the filtered CTP data, compared to those derived from the original data. Results showed that arteriograms and venograms derived from the filtered CTP data showed more and better visualized small arteries and veins in the majority of the 20 evaluated CTP scans. In conclusion, arteries and veins are separately enhanced and noise is reduced by using the time-intensity profile similarity (fourth dimension) to distinguish between structures for anisotropic diffusion filtering in 4D CT perfusion scans.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Wintermark, M.: Brain perfusion-CT in acute stroke patients. Eur. Radiol. 15(suppl. 4), D28āD31 (2005)
Zhu, G., Michel, P., Aghaebrahim, A., Patrie, J.T., Xin, W., Eskandari, A., Zhang, W., Wintermark, M.: Computed tomography workup of patients suspected of acute ischemic stroke perfusion computed tomography adds value compared with clinical evaluation, noncontrast computed tomography, and computed tomography angiogram in terms of predicting outcome. Stroke 44(4), 1049ā1055 (2013)
Salomon, E.J., Barfett, J., Willems, P.W., Geibprasert, S., Bacigaluppi, S., Krings, T.: Dynamic ct angiography and ct perfusion employing a 320-detector row ct. Clinical Neuroradiology 19(3), 187ā196 (2009)
Mendrik, A.M., Vonken, E.P., van Ginneken, B., Smit, E.J., Waaijer, A., Bertolini, G., Viergever, M.A., Prokop, M.: Automatic segmentation of intracranial arteries and veins in four-dimensional cerebral ct perfusion scans. Med. Phys. 37(6), 2956ā2966 (2010)
Mendrik, A.M., Vonken, E.P., de Kort, G.A., van Ginneken, B., Smit, E.J., Viergever, M.A., Prokop, M.: Improved arterial visualization in cerebral ct perfusion-derived arteriograms compared with standard ct angiography: A visual assessment study. American Journal of Neuroradiology 33(11), 2171ā2177 (2012)
Smit, E.J., Vonken, E., van der Schaaf, I.C., Mendrik, A.M., Dankbaar, J.W., Horsch, A.D., van Seeters, T., van Ginneken, B., Prokop, M.: Timing-invariant reconstruction for deriving high-quality ct angiographic data from cerebral ct perfusion data. Radiology 263(1), 216ā225 (2012)
Kosior, J.C., Kosior, R.K., Frayne, R.: Robust dynamic susceptibility contrast MR perfusion using 4D nonlinear noise filters. J. Magn. Reson. Imaging 26(6), 1514ā1522 (2007)
Gal, Y., Mehnert, A.J.H., Bradley, A.P., McMahon, K., Kennedy, D., Crozier, S.: Denoising of dynamic contrast-enhanced mr images using dynamic nonlocal means. IEEE Trans. Med. Imaging 29(2), 302ā310 (2010)
Mendrik, A.M., Vonken, E., van Ginneken, B., de Jong, H.W., Riordan, A., van Seeters, T., Smit, E.J., Viergever, M.A., Prokop, M.: Tips bilateral noise reduction in 4d ct perfusion scans produces high-quality cerebral blood flow maps. Physics in Medicine and Biology 56(13), 3857 (2011)
Weickert, J.: A Review of Nonlinear Diffusion Filtering. Scale-Space Theory in Computer Vision. LNCS. vol. 1252, pp. 3ā28 (1997)
Weickert, J.: Anisotropic diffusion in image processing. B.G. Teubner, Stuttgart (1998)
Montagnat, J., Sermesant, M., Delingette, H., Malandain, G., Ayache, N.: Anisotropic Filtering for Model Based Segmentation of 4D Cylindrical Echocardiographic Images. Pattern Recognition Letters 24, 815ā828 (2002)
Sanchez-Ortiz, G.I., Rueckert, D., Burger, P.: Knowledge-based tensor anisotropic diffusion of cardiac magnetic resonance images. Medical Image Analysis 3(1), 77ā101 (1999)
Tauber, C., Stute, S., Chau, M., Spiteri, P., Chalon, S., Guilloteau, D., Buvat, I.: Spatio-temporal diffusion of dynamic pet images. Physics in Medicine and Biology 56(20), 6583 (2011)
Mendrik, A.M., Vonken, E.J., Rutten, A., Viergever, M.A., van Ginneken, B.: Noise reduction in computed tomography scans using 3-d anisotropic hybrid diffusion with continuous switch. IEEE Trans. Med. Imaging 28(10), 1585ā1594 (2009)
Enquobahrie, A., Yang, H., Aylward, S.: Implementation of Local Structure Tensor and Enhancement Anisotropic Diffusion Filters in ITK. The Insight Journal 8 (2010)
Weickert, J.: Coherence-Enhancing Diffusion Filtering. International Journal of Computer Vision 31(2ā3), 111ā127 (1999)
Weickert, J., Scharr, H.: A Scheme for Coherence-Enhancing Diffusion Filtering with Optimized Rotation Invariance. Journal of Visual Communication and Image Representation 13(1ā2), 103ā118 (2002)
Altman, D.G.: Practical Statistics for Medical Research (Statistics texts). 1 edn. Chapman & Hall (November 1990)
Manniesing, R., Viergever, M.A., Niessen, W.J.: Vessel enhancing diffusion: A scale space representation of vessel structures. Medical Image Analysis 10(6), 815ā825 (2006)
Frangi, A.F., Niessen, W.J., Vincken, K.L., Viergever, M.A.: Multiscale Vessel Enhancement Filtering. In: Wells, W.M., Colchester, A.C.F., Delp, S.L. (eds.) MICCAI 1998. LNCS, vol. 1496, pp. 130ā137. Springer, Heidelberg (1998)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
Ā© 2015 Springer International Publishing Switzerland
About this paper
Cite this paper
Mendrik, A.M., Vonken, Ej., Witkamp, T., Prokop, M., van Ginneken, B., Viergever, M.A. (2015). Using the Fourth Dimension to Distinguish Between Structures for Anisotropic Diffusion Filtering in 4D CT Perfusion Scans. In: Durrleman, S., Fletcher, T., Gerig, G., Niethammer, M., Pennec, X. (eds) Spatio-temporal Image Analysis for Longitudinal and Time-Series Image Data. STIA 2014. Lecture Notes in Computer Science(), vol 8682. Springer, Cham. https://doi.org/10.1007/978-3-319-14905-9_7
Download citation
DOI: https://doi.org/10.1007/978-3-319-14905-9_7
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-14904-2
Online ISBN: 978-3-319-14905-9
eBook Packages: Computer ScienceComputer Science (R0)