Abstract
Nowadays, the Metabolic Equivalent Task (MET) is the most often used indicator for energy expenditure (EE) calculation of physical activity (PA). The use of novel devices based on inertial movements (e.g. accelerometers) enable the measurement of the PA using “counts”:, where each count is an aggregated value that can be used to determine the number of METs. For some kind of users, such as elderly people or patients in AAL environments, the MET is an important indicator in order to maintain a good health. At present, there exist several types of inertial devices that enable different forms of count calculation and types of exercise monitoring. From the point of view of process analysis and infrastructure needed, they differ in several aspects, such as extra devices required and out-of-device processing. This paper presents a survey analysis about the possibilities of different types of accelerometers to measure EE in AAL contexts. To achieve this objective, we have conducted several experiments based on the performing of different exercises with different accelerometers placed in different body parts.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
World Health Organization. Milestones in health promotion: Statements from Global Conferences (2009)
U.S. Department of Health and Human Services. Physical Activity and Health: A Report of the Surgeon General. Atlanta, GA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Chronic Disease Prevention and Health Promotion (1996)
Sallis, J.F., Saelens, B.E.: Assessment of physical activity by self-report: status, limitations, and future directions. Research quarterly for exercise and sport 71(2 Suppl), S1–S14 (2000)
Goran, M.I., Poehlman, E.T.: Total energy expenditure and energy requirements in healthy elderly persons. Metabolism 41(7), 744–753 (1992)
Ainsworth, B.E., et al.: Compendium of physical activities: an update of activity codes and MET intensities. Medicine and Science in Sports and Exercise 32(9, Supp/1), S498–S504 (2000)
Byrne, N.M., et al.: Metabolic equivalent: one size does not fit all. Journal of Applied Physiology 99(3), 1112–1119 (2005)
Freedson, P.S., et al.: Evaluation of artificial neural network algorithms for predicting METs and activity type from accelerometer data: validation on an independent sample. Journal of Applied Physiology 111(6), 1804–1812 (2011)
Yang, C.-C., Hsu, Y.-L.: A review of accelerometry-based wearable motion detectors for physical activity monitoring. Sensors 10(8), 7772–7788 (2010)
Chen, K.Y., Bassett, D.R.: The technology of accelerometry-based activity monitors: current and future. Medicine and Science in Sports and Exercise 37(11), S490 (2005)
Calloway, D.H.: Zanni, Eleni. Energy requirements and energy expenditure of elderly men. The American Journal of Clinical Nutrition 33(10), 2088–2092 (1980)
Pinheiro Volp, A.C., et al.: Energy expenditure: components and evaluation methods. Nutr. Hosp. 26(3), 430–440 (2011)
Garatachea, N., Torres Luque, G., Gonzalez Gallego, J.: Physical activity and energy expenditure measurements using accelerometers in older adults. Nutr. Hosp. 25(2), 224–230 (2010)
Bourke, A.K., et al.: Embedded fall and activity monitoring for a wearable ambient assisted living solution for older adults. In: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE, pp. 248–251. IEEE (2012)
Goran, M.I., Poehlman, E.T.: Endurance training does not enhance total energy expenditure in healthy elderly persons. American Journal of Physiology 263, E950-E950 (1992)
Clegg, A., et al.: Frailty in elderly people. The Lancet 381(9868), 752–762 (2013)
Tallarida, R.J., Murray, R.B.: Area under a Curve: Trapezoidal and Simpson’s Rules. In: Manual of Pharmacologic Calculations, pp. 77–81. Springer, New York (1987)
Santos-Lozano, A., et al.: Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points. International Journal of Sports Medicine 34(11), 975–982 (2013)
Ainsworth, B.E., et al.: Compendium of physical activities: an update of activity codes and MET intensities. Medicine and Science in Sports and Exercise 32(9 Supp/1), S498–S504 (2000)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Ruiz-Zafra, Á., Gonzalez, E.O., Noguera, M., Benghazi, K., Heredia Jiménez, J.M. (2014). Energy Expenditure Analysis: A Comparative Research of Based on Mobile Accelerometers. In: Pecchia, L., Chen, L.L., Nugent, C., Bravo, J. (eds) Ambient Assisted Living and Daily Activities. IWAAL 2014. Lecture Notes in Computer Science, vol 8868. Springer, Cham. https://doi.org/10.1007/978-3-319-13105-4_7
Download citation
DOI: https://doi.org/10.1007/978-3-319-13105-4_7
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-13104-7
Online ISBN: 978-3-319-13105-4
eBook Packages: Computer ScienceComputer Science (R0)