Development of a Novel Micro-motion Dental Implant System

  • Conference paper

Part of the book series: IFMBE Proceedings ((IFMBE,volume 47))

Abstract

Dental implantation has brought about not only the occlusive capability restoration for edentulous patients, but also provided a better choice for the tooth reconstruction. With the advancements of science and technology, a satisfactory success rate of the dental implantation was reported. However, the mechanical behavior of the dental implant is still not similar to a natural tooth with the periodontal ligament. The micro-motion mechanism is the main difference between the natural tooth and the dental implant. Therefore, the aim of this study was to develop a novel dental implant abutment with a micro-motion mechanism that imitates the biomechanical behavior of the periodontal ligament, with the goal of not only maintaining the primal success rate but also increasing the long-term survival rate of dental implants. Firstly, computer-aided design software was used to design a novel dental implant abutment with an internal resilient component with a micro-motion capability. The feasibility of the novel system was investigated via finite element analysis. Then, a prototype of the novel dental implant abutment was fabricated, and the mechanical behavior was evaluated. The compression test of the novel dental implant was performed to prove micro-motion function. Moreover, the fatigue test of the novel dental implant was executed on the basis of the ISO 14801 standard. The results of the finite element analysis and the compression test confirmed that the novel dental implant abutment possessed the anticipated micro-motion capability. The nonlinear force-displacement behavior apparent in this micro-motion mechanism imitated the movement of a human tooth. Furthermore, the novel dental implant accomplished the fatigue test successfully at 5,000,000 cycles with frequencies of 5 Hz. The maximum endured load of the fatigue resistance of the novel dental implant is 160 N according to the ISO 14801 standard.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Chen, Y.Y., Chen, W.P., Chang, H.H., Huang, S.H., Lin, C.P. (2015). Development of a Novel Micro-motion Dental Implant System. In: Su, FC., Wang, SH., Yeh, ML. (eds) 1st Global Conference on Biomedical Engineering & 9th Asian-Pacific Conference on Medical and Biological Engineering. IFMBE Proceedings, vol 47. Springer, Cham. https://doi.org/10.1007/978-3-319-12262-5_26

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-12262-5_26

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-12261-8

  • Online ISBN: 978-3-319-12262-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics