Abstract
A 500 MW turbine generator set that operated through a rigorous two shift regime had developed a crack whilst in service. The shaft line was regularly subjected to multiple starts with oil whirl manifesting on load during certain operational conditions. First observations on generator no. 11 bearing showed an increase in the 1× component over a period of time, with changes through the critical speed during run-down triggering close monitoring. Further observations over time revealed that the Low Pressure turbine three, 1× and 2× components increased during steady state in conjunction with changes in phase angles and critical speed during transient conditions. Early indications showed that the likelihood of a crack in the main turbine shaft was high. Further observations over time revealed that the 1× and 2× steady state trends continued to increase up to the ISO limits set for the turbine generator set. The unit was shut down and qualitative inspections undertaken. The findings revealed that a crack had developed on the main rotor body in the pencil shaft.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bloch PH, Singh PM (2009) Steam turbines—design applications and re-rating, 2nd edn. McGraw-Hill Companies, New York
Sinha J, Hahn W, Elbhbah K et al (2012) Vibration investigation for low pressure turbine last stage blade failure in steam turbines of a power plant. In: Proceedings of the ASME Turbo Expo 2012, Copenhagen, Denmark
Bachschmid N, Pennachi P et al (2010) Cracked rotors—a survey on static and dynamic behaviour including modelling and diagnosis. Springer, Berlin
Jonas O, Mchemer L (2008) Steam turbine corrosion and deposits problems and solutions. In: Proceedings of the thirty-seventh turbo machinery symposium, Jonas Inc., Wilmington, Delaware
Davies WGR, Mayes IW (1984) The vibrational behaviour of a multi-shaft, multi-bearing system in the presence of a propagating transverse crack. J Vibr Acoust Stress Reliab Des 106:146–153
Futter D (2012) West Burton Power Station: Unit 4: vibration changes prior to forced outage June 2012. Eon New Build and Technology report ENT/12/TMR/CM/855/R
BS ISO 10816-2 (2009) Mechanical vibration—Evaluation of machine vibration by measurements on non rotating parts
Poursaeidi E, Kamalzedeh Y (2011) Causes of rotor distortions and applicable common straightening methods for turbine rotors and shafts. World Academy of Science and Technology 55 of 2011, pp 213–218
Mikkelsen T, Siemens, NDT03-2013, Automated UT examination of the west Burton Unit 4 LP3 Turbine and the retired LP1 spindle, 70PO03636
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this paper
Cite this paper
Hahn, W., Futter, D. (2015). Crack Propagation in a 500 MW LP Turbine in Service. In: Sinha, J. (eds) Vibration Engineering and Technology of Machinery. Mechanisms and Machine Science, vol 23. Springer, Cham. https://doi.org/10.1007/978-3-319-09918-7_26
Download citation
DOI: https://doi.org/10.1007/978-3-319-09918-7_26
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-09917-0
Online ISBN: 978-3-319-09918-7
eBook Packages: EngineeringEngineering (R0)