Abstract
A sampling Moire method is one of a deformation measurement method of a large structure such as a building and a bridge. The accuracy of phase difference analysis is from 1/100 to 1/1,000 of the grating pitches. This method can analyze two-dimensional phases from a two-dimensional grating image attached on the surface of a specimen. The phase difference distribution before and after deformation gives displacement distributions for the x- and the y-directions. Grating phase also gives position for the x- and the y-directions. Therefore, the relationship between a point on an image and the corresponding point on the object can be obtained without any calibrations. A sampling Moire camera we proposed has an FPGA with an algorithm of the sampling Moire method inside the camera. It can output two-dimensional phases and phase differences from a single shot two-dimensional grating image in real-time. In this paper, a measurement accuracy of the deformation distribution measurement using the sampling Moire camera placed in the oblique direction is estimated. Experimental result of the time-series deformation measurement of a moving cantilever is shown.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Arai Y, Yokozeki S, Shiraki K, Yamada T (1997) High precision two-dimensional spatial fringe analysis method. J Mod Opt 44(4):739–751
Ri S, Fujigaki M, Morimoto Y (2010) Sampling Moire method for accurate small deformation distribution measurement. Exp Mech 50(4):501–508
Shimo K, Fujigaki M, Masaya A, Morimoto Y (2009) Development of dynamic shape and strain measurement system by sampling Moire method. In: Proceedings of SPIE, 7522, ICEM2009
Hanada R, Miyazawa M, Fujigaki M, Simo K, Morimoto Y (2013) A sampling Moire method to measure the dynamic shape and strain of rotating tires. Tire Sci Technol 41(3):214–225
Takeda M, Ina H, Kobayashi S (1982) Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry. Opt Soc Am 72(1):156–160
Yoneyama S, Kitagawa A, Kitamura K, Kikuta H (2006) In-plane displacement measurement using digital image correlation with lens distortion correction. JSME Int J Ser A 49(3):458–467
Fujigaki M, Sasatani Y, Masaya A, Kondo H, Nakabo M, Hara T, Morimoto Y, Asai D, Miyagi T, Kurokawa N (2011) Development of sampling Moire camera for real-time phase analysis. Appl Mech Mater 83:48–53
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 The Society for Experimental Mechanics, Inc.
About this paper
Cite this paper
Tomita, D., Fujigaki, M., Murata, Y. (2015). Deformation Distribution Measurement from Oblique Direction Using Sampling Moire Method. In: Jin, H., Sciammarella, C., Yoshida, S., Lamberti, L. (eds) Advancement of Optical Methods in Experimental Mechanics, Volume 3. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, Cham. https://doi.org/10.1007/978-3-319-06986-9_22
Download citation
DOI: https://doi.org/10.1007/978-3-319-06986-9_22
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-06985-2
Online ISBN: 978-3-319-06986-9
eBook Packages: EngineeringEngineering (R0)