Skip to main content

Design and Implementation of a Calibration - Free Pulse Oximeter

  • Conference paper
The 15th International Conference on Biomedical Engineering

Part of the book series: IFMBE Proceedings ((IFMBE,volume 43))

Abstract

Oxygen saturation in human beings is measured as the ratio of the amount of oxygen carried by hemoglobin to the maximum amount it could carry. A pulse oximeter is a device which measures this saturated oxygen content using the technique of photoplethysmography. Generally, the device consists of two LEDs (Red and IR) as light sources, and a photo diode as the detector. Depending on the intensity of light transmitted or reflected to the detector, oxygen saturation is computed. Commercially available pulse oximeters require calibration, since the device is dependent on sensor and patient-dependent parameters like skin color and thickness of the digit. This is normally done by acquiring data from volunteers, after which the necessary coefficients are extracted, for computing the saturated oxygen content. Such a calibration technique is dependent on the sample population, and hence is undesirable. The work presented here, makes use of a calibration-free algorithm published earlier, incorporating it into a micro-controller, leading to a compact, power-efficient, pulse oximeter. Moreover, present day pulse oximeters do not give access to the raw PPG data, which could be used for extracting important cardiovascular parameters. The preliminary design presented here provides a serial port interface in order to acquire and communicate the PPG signal to a PC, for further offline analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this paper

Cite this paper

Harini, H., Krithika, L.S., Shalini, M., Swaminathan, S., Madhu Mohan, N. (2014). Design and Implementation of a Calibration - Free Pulse Oximeter. In: Goh, J. (eds) The 15th International Conference on Biomedical Engineering. IFMBE Proceedings, vol 43. Springer, Cham. https://doi.org/10.1007/978-3-319-02913-9_26

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-02913-9_26

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-02912-2

  • Online ISBN: 978-3-319-02913-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics