Abstract
Soft-first-story structures, such as piloti buildings, are known as vulnerable structures against earthquakes. In this chapter, a simple scheme for reducing the structural damage of such buildings is proposed. Its effectiveness is experimentally examined through substructure pseudo-dynamic tests. In the proposed method, low yield strength steel devices are applied as elasto-plastic dampers at the first story of the buildings to reduce the seismic response and damage. A six-story single-span piloti model, with or without steel dampers, are the subject of the test. The behavior of the two exterior columns at the first story and the steel damper are tested. The substructure pseudo-dynamic tests are successfully performed to investigate the elasto-plastic behavior of the damper and the reinforced concrete columns at the soft-first-story, as well as the overall structural performance. The experimental results show that the seismic damage of piloti buildings can be reduced with steel dampers, which have been found to work as effectively as expected.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Iqbal A (2006) Soft first storey with seismic isolation system. In: NZSEE conference, Napier, CDROM paperID 36
Kaushik HB, Rai DC, Jain SK (2009) Effectiveness of some strengthening options for masonry-infilled RC frames with open first storey. J Struct Eng ASCE 135(8):925–937
Lu Y, Tassios TP, Zhang G-F, Vintzileou E (1999) Seismic response of reinforced concrete frames with strength and stiffness irregularities. ACI Struct J 96(2):221–229
Mezzi M, Parducci A (2005) Preservation of existing soft-first-storey configurations by improving the seismic performance. In: 3rd specialty conference on the conceptual approach to structural design
Naeim F, Lew M (2000) The 1999 earthquake disasters worldwide: how many times do we have to re-learn the fundamentals of seismic engineering? Struct Des Tall Build 9(2):161–182
Nakamura T, Hori N, Inoue N (1998) Evaluation of damaging properties of ground motions and estimation of maximum displacement based on momentary input energy. J Struct Constr Eng (in Japanese) 513:65–72
Nakashima M, Kaminosono T, Ishida M, Ando K (1990) Integration techniques for substructure pseudo-dynamic test. In: 4th US national conference on earthquake engineering, vol 2, pp 512–524
Teramoto N, Nishida T, Kobayashi J (2008) Structural performance of side columns subjected to varying axial load. In: 14th world conference on earthquake engineering, paper-ID 05-03-0234
Todorovska MI (1999) Base isolation by a soft first storey with inclined columns. J Eng Mech ASCE 1254:448–457
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Kanno, H., Nishida, T., Kobayashi, J. (2014). Substructure Pseudo-Dynamic Tests on Seismic Response Control of Soft-First-Story Buildings. In: Ilki, A., Fardis, M. (eds) Seismic Evaluation and Rehabilitation of Structures. Geotechnical, Geological and Earthquake Engineering, vol 26. Springer, Cham. https://doi.org/10.1007/978-3-319-00458-7_19
Download citation
DOI: https://doi.org/10.1007/978-3-319-00458-7_19
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-00457-0
Online ISBN: 978-3-319-00458-7
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)