Skip to main content

FRP Local Retrofit of Non-Conforming RC Beam-Column Joints

  • Chapter
  • First Online:

Part of the book series: Geotechnical, Geological and Earthquake Engineering ((GGEE,volume 26))

Abstract

Recent seismic events have clearly confirmed the vulnerability of existing reinforced concrete (RC) structures. In particular, field observation of structures damaged by L’Aquila earthquake strongly confirmed that premature failure of partially confined (i.e. exterior) beam-column joints was one of the main causes limiting the global structural seismic capacity. Poor attention to details and a lack of adequate transverse reinforcement typically lead to premature brittle shear failure of joints. To provide support to practitioners involved in the L’Aquila reconstruction process, a proper guideline which illustrates the design of local retrofit interventions on structural and non structural elements has been edited by the Italian Civil Protection Department (DPC) and the Laboratories University Network of Seismic Engineering (ReLUIS). In particular, a viable FRP strengthening strategy to increase the seismic performances of partially confined joints (design procedure and installation steps) is widely discussed and presented in the document. To validate the strengthening system recommended in this guideline, an experimental program has been carried out on as-built and FRP strengthened full scale corner RC joints (T shaped joints). After presenting the main guideline recommendations for local strengthening of existing structures, the paper focuses on the experimental program activity; in particular, the specimen design strategy and test setup definition as well as the comparative analysis of the behavior of tested joints.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Abbreviations

b c :

column width

b b :

beam width

d :

beam tip displacement

d 0 :

beam tip displacement for gravity load

f c :

concrete cylindrical compressive strength

f cm :

concrete average cylindrical compressive strength

h c :

column height

h b :

beam height

p t :

average principle tensile stress

t f,eq :

equivalent thickness of FRP dry fibres for each direction.

A g = b c .h c :

column gross concrete area

E eq :

energy dissipation associated to the equivalent elastoplastic system

L :

beam free length

P :

column axial load

V c :

column shear

V c,MAX :

experimental column shear peak value

V jh :

joint panel shear strength

ε y :

steel rebars yielding strain

ε FRP :

FRP strain

ν = P/ (A g .f cm ) :

axial load ratio

μ :

subassemblage ductility

Δ u :

ultimate drift

Δ y :

drift at yielding

References

  • ACI 369R-11 (2011) American Concrete Institute, committee 369: guide for seismic rehabilitation of existing concrete frame buildings and commentary, February 2011, USA

    Google Scholar 

  • AIJ (1999) Architectural Institute of Japan. Design guideline for earthquake resistant reinforced concrete buildings based on inelastic displacement concept, Tokyo

    Google Scholar 

  • Antonopoulos CP, Triantafillou TC (2003) Experimental investigation of FRP-strengthened RC beam-column joints. ASCE J Compos Constr 7(1):39–49

    Article  Google Scholar 

  • ASCE/SEI 41–06 (2007) Seismic rehabilitation of existing buildings. American Society of Civil Engineers, Reston, pp 428

    Google Scholar 

  • Beres A, Pessiki SP, White RN, Gergely P (1996) Implications of experiments on the seismic behaviour of gravity load designed RC beam-to-column connections. Earthq Spectra 12(2):185–198

    Article  Google Scholar 

  • CNR-DT 200 (2004) National Research Council: guide for design and construction of externally bonded FRP systems for strengthening existing structures. CNR, Rome, 13 July 2004

    Google Scholar 

  • Di Ludovico M, Balsamo A, Prota A, Manfredi G (2008) Comparative assessment of seismic rehabilitation techniques on a full-scale 3-storey RC moment frame structure. Struct Eng Mech 28(6):727–747

    Google Scholar 

  • DM 14 Gennaio 2008 (DM 2008) Technical codes for structures (in Italian). GU n°29, Feb 2 2008, Supplemento Ordinario n°30, Rome

    Google Scholar 

  • DPC/ReLUIS (2011) Guidelines for repair and strengthening of structural elements, infill and partitions (in Italian) by Dolce M, Manfredi G, Doppiavoce Dec 2011. ISBN 978-88-89972-29-8, pp. 194

    Google Scholar 

  • European Standard (EN 1998–1:2004) Eurocode 8: design of structures for earthquake resistance. Part 1: general rules, seismic actions and rules for buildings, Brussels, December 2004

    Google Scholar 

  • Fardis MN (2009) Seismic design, assessment and retrofitting of concrete buildings based on EN-Eurocode 8, vol 8, Geotechnical, geological and earthquake engineering. Springer, Dordrecht. ISBN 978-1-4020-9841-3

    Book  Google Scholar 

  • Gergely I, Pantelides CP, Reaveley LD (2000) Shear strengthening of RC T-joints using CFRP composites. ASCE J Compos Constr 4(2):56–64

    Article  Google Scholar 

  • Ghobarah A, El-Amoury T (2002) Seismic rehabilitation of beam-column joint using GFRP sheets. Eng Struct 24:1397–1407

    Article  Google Scholar 

  • Ghobarah A, El-Amoury T (2005) Seismic rehabilitation of deficient exterior concrete frame joints. ASCE J Compos Constr 9(5):408–416

    Article  Google Scholar 

  • Hakuto S, Park R, Tanaka H (1995) Retrofitting of reinforced concrete moment resisting frames. Research report 95–4, Department of Civil Engineering, University of Canterbury, Christchurch

    Google Scholar 

  • LaFave JM, Kim J (2011) Joint shear behaviour prediction for RC beam-column connections. Int J Concr Struct Mater 5(1):57–64

    Google Scholar 

  • Pampanin S, Calvi GM, Moratti M (2002) Seismic behaviour of RC beam-column joints designed for gravity loads. In: Proceedings of the 12th European conference on earthquake engineering, London, September 2002. Paper reference 726

    Google Scholar 

  • Pantelides CP, Clyde C, Reaveley LD (2002) Performance-based evaluation of reinforced concrete building exterior joints for seismic excitation. Earthq Spectra 18(3):449–480

    Article  Google Scholar 

  • Park R (1988) Ductility evaluation from laboratory and analytical testing. In: Proceedings of the 9th world conference on earthquake engineering, vol VIII. Tokyo-Kyoto, pp 605–616

    Google Scholar 

  • Park R (1992) Simulated seismic load tests on reinforced concrete elements and structures. In: Proceedings of the 10th world conference on earthquake engineering, Balkema, Rotterdam, pp 6681–6693. ISBN 9054100605

    Google Scholar 

  • Park S, Mosalam KM (2012) Parameters for shear strength prediction of exterior beam-column joints without transverse reinforcement. Eng Struct 36:198–209

    Article  Google Scholar 

  • Paulay T, Priestley MJN (1992) Seismic design of reinforced concrete and masonry buildings. Wiley, New York, pp 250–303

    Book  Google Scholar 

  • Priestley MJN (1997) Displacement-based seismic assessment of reinforced concrete buildings. J Earthq Eng 1:157–192

    Google Scholar 

  • Prota A, Nanni A, Manfredi G, Cosenza E (2004) Selective upgrade of under-designed reinforced concrete beam-column joints using carbon fibre- reinforced polymers. ACI Struct J Title n 101 (S69) (2):699–707

    Google Scholar 

  • Tsonos G (2008) Effectiveness of CFRP-jackets and RC-jackets in post-earthquake and pre-earthquake retrofitting of beam-column sub-assemblages. Eng Struct 30(3):777–793

    Article  Google Scholar 

Download references

Acknowledgments

This study was performed in the framework of PE 2010–2013: joint DPC-ReLUIS project, Task 3.1. The materials used for joints strengthening were donated by Mapei Spa, Milano.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marco Di Ludovico .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this chapter

Cite this chapter

Prota, A., Di Ludovico, M., Balsamo, A., Moroni, C., Dolce, M., Manfredi, G. (2014). FRP Local Retrofit of Non-Conforming RC Beam-Column Joints. In: Ilki, A., Fardis, M. (eds) Seismic Evaluation and Rehabilitation of Structures. Geotechnical, Geological and Earthquake Engineering, vol 26. Springer, Cham. https://doi.org/10.1007/978-3-319-00458-7_14

Download citation

Publish with us

Policies and ethics