Skip to main content

Advantages and Limitations of Intraoperative 3D Ultrasound in Neurosurgery. Technical note

  • Chapter
  • First Online:
Intraoperative Imaging

Abstract

Three-dimensional ultrasound (US) technology is supposed to help combat some of the orientation difficulties inherent to two-dimensional US. Contemporary navigation solutions combine reconstructed 3D US images with common navigation images and support orientation. New real-time 3D US (without neuronavigation) is more time effective, but whether it further assists in orientation remains to be determined. An integrated US system (IGSonic, VectorVision², BrainLAB, Munich Germany) and a non-integrated system with real-time 3D US (iU22, Philips, Bothell, USA) were recently compared in neurosurgical procedures in our group. The reconstructed navigation view was time-consuming, but images were displayed in familiar planes (e.g., axial, sagittal, coronal). Further potential applications of US angiography and pure US navigation are possible. Real-time 3D images were displayed without the need for an additional acquisition and reconstruction process, but spatial orientation remained challenging in this preliminary testing phase. Reconstructed 3D US navigation appears to be superior with respect to spatial orientation, and the technique can be combined with other imaging data. However, the potential of real-time 3D US imaging is promising.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 219.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 279.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Bernays RL (2003) Intraoperative imaging in neurosurgery. MRI, CT, ultrasound. Introduction. Acta Neurochir Suppl 85:1–3

    Article  PubMed  CAS  Google Scholar 

  2. Bonsanto MM, Staubert A, Wirtz CR, Tronnier V, Kunze S (2001) Initial experience with an ultrasound-integrated single-rack neuronavigation system. Acta Neurochir 143:1127–1132

    Article  CAS  Google Scholar 

  3. Cannon JW, Stoll JA, Sago IS, Knowles HB, Howe RD, Dupont PE, Marx GR, del Nido PJ (2003) Real-time three-dimensional ultrasound for guiding surgical tasks. Comput Aided Surg 8:82–90

    Article  PubMed  Google Scholar 

  4. Enchev Y, Bozinov O, Miller D, Tirakotai W, Heinze S, Benes L, Bertalanffy H, Sure U (2006) Image-guided ultrasonography for recurrent cystic gliomas. Acta Neurochir 148:1053–1063

    Article  CAS  Google Scholar 

  5. Jödicke A, Deinsberger W, Erbe H, Kriete A, Böker D-K (1998) Intraoperative three-dimensional ultrasonography: an approach to register brain shift using multidimensional image processing. Minim Invas Neurosurg 41:13–19

    Article  Google Scholar 

  6. Jödicke A, Springer T, Böker D-K (2004) Real-time integration of ultrasound into neuronavigation: technical accuracy using a light-emitting-diode-based navigation system. Acta Neurochir 146:1211–1220

    Article  Google Scholar 

  7. Lindner D, Trantakis C, Renner C, Arnold S, Schmitgen A, Schneider J, Meixensberger J (2006) Application of intraoperative 3D ultrasound during navigated tumor resection. Minim Invasive Neurosurg 49:197–202

    Article  PubMed  CAS  Google Scholar 

  8. Lindseth F, Kaspersen JH, Ommedal S, Lango T, Bang J, Hokland J, Unsgaard G, Hernes TA (2003) Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by integrating preoperative MRI with intraoperative 3D ultrasound. Comput Aided Surg 8:49–69

    Article  PubMed  Google Scholar 

  9. Unsgaard G, Rygh GM, Selbekk T, Müller TB, Kolstad F, Lindseth F, Nagelhus Hernes TA (2006) Intra-operative 3D ultrasound in neurosurgery. Acta Neurochir 148:235–254

    Article  CAS  Google Scholar 

  10. Sure U, Benes L, Bozinov O, Woydt M, Tirakotai W, Bertalanffy H (2005) Intraoperative landmarking of vascular anatomy by integration of duplex and Doppler ultrasonography in image guided surgery. Technical note. Surg Neurol 63:133–142

    Article  PubMed  Google Scholar 

  11. Tirakotai W, Miller D, Heinze S, Benes L, Bertalanffy H, Sure U (2006) A novel platform for image-guided ultrasound. Neurosurgery 58:710–718

    Article  PubMed  Google Scholar 

  12. Unsgaard G, Ommedal S, Muller T, Gronningsaeter A, Nagelhus Hernes TA (2002) Neuronavigation by intraoperative three-dimensional ultrasound: initial experience during brain tumor resection. Neurosurgery 50:804–812

    Article  PubMed  Google Scholar 

  13. Sure U, Alberti O, Petermeyer M, Becker R, Bertalanffy H (2000) Advanced image-guided skull base surgey. Surg Neurol 53:563–572

    Article  PubMed  CAS  Google Scholar 

  14. Miller D, Heinze S, Tirakotai W, Bozinov O, Sürücü O, Benes L, Bertalanffy H, Sure U (2007) Is the image guidance of ultrasonography beneficial for neurosurgical routine? Surg Neurol 67:579–587

    Article  PubMed  Google Scholar 

  15. Sure U, Gatscher S, Alberti O, Witte J, Bertalanffy H (2000) Image-guided duplex and Doppler ultrasound for microsurgery of cerebral AVMs. Zentralbl Neurochir 61(Suppl 1):47–48 (abstract)

    Google Scholar 

  16. Woydt M, Horowski A, Krauss J, Krone A, Soerensen N, Roosen K (2002) Three-dimensional intraoperative ultrasound of vascular malformations and supratentorial tumors. J Neuroimaging 12:28–34

    Article  PubMed  Google Scholar 

  17. Unsgaard G, Ommedal S, Rygh OM, Lindseth F (2007) Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography. Neurosurgery 61(1 Suppl):407–415

    PubMed  Google Scholar 

  18. Gronningsaeter A, Kleven A, Ommedal S, Aarseth TE, Lie T, Lindseth F, Lango T, Unsgard G (2000) SonoWand, an ultrasound-based neuronavigation system. Neurosurgery 47:1373–1380

    Article  PubMed  CAS  Google Scholar 

  19. Winkler D, Lindner D, Strauss G, Richter A, Schober R, Meixensberger J (2006) Surgery of cavernous malformations with and without navigational support–a comparative study. Minim Invasive Neurosurg 49:15–19

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgment

The authors state that both US probes (IGSonic and real-time 3D transducer) have been provided by the companies for research proposes. This is not the case for the navigation system VectorVision or US system IU22, which were bought by the departments. No further financial collaborations, consulting contracts or conflicts of interest exist. The reprint of the image in Fig.3b has been approved by the company (Copyright Philips, Bothell, USA).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Oliver Bozinov .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag/Wien

About this chapter

Cite this chapter

Bozinov, O., Burkhardt, JK., Fischer, C.M., Kockro, R.A., Bernays, RL., Bertalanffy, H. (2011). Advantages and Limitations of Intraoperative 3D Ultrasound in Neurosurgery. Technical note. In: Pamir, M., Seifert, V., Kiris, T. (eds) Intraoperative Imaging. Acta Neurochirurgica Supplementum, vol 109. Springer, Vienna. https://doi.org/10.1007/978-3-211-99651-5_30

Download citation

  • DOI: https://doi.org/10.1007/978-3-211-99651-5_30

  • Published:

  • Publisher Name: Springer, Vienna

  • Print ISBN: 978-3-211-99650-8

  • Online ISBN: 978-3-211-99651-5

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics