Summary
Implanted programmable pumps that infuse intrathecal baclofen (ITB) markedly enhance the ability of clinicians to manage severe spasticity in appropriately selected patients. Studies addressing the efficacy of this treatment modality have primarily used clinical outcome measures of impairment, particularly reduction in stiffness as measured by the Ashworth scale. Several recent studies, however, highlight comparatively higher sensitivity of neurophysiologic techniques, especially the H-reflex, as an objective index of spinal cord response to ITB administration. We review the conceptual, physiological, and methodological bases for use of the H-reflex as an adjunct to clinical evaluation among patients receiving ITB infusion, including published reports and selected case studies that address the potential advantages and limitations of such techniques when applied to dose titration and system “troubleshooting” scenarios. We also address the implications of such findings in the context of reported complications such as “tolerance” to ITB administration and catheter “microfracture.” The accumulated knowledge suggests that H-reflex is a sensitive method for documenting altered spinal cord responsiveness in the presence of ITB delivery. We therefore recommend using H-reflex as an adjunct to clinical evaluation when judging the overall effectiveness of ITB administration.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Akman MN, Loubser PG, Donovan WH, O’Neill ME, Rossi CD (1993) Intrathecal baclofen: does tolerance occur? Paraplegia 31: 516–520
Azouvi P, Roby-Brami A, Biraben A, Thiebaut JB, Thurel C, Bussel B (1993) Effect of intrathecal baclofen on the monosynaptic reflex in humans: evidence for a postsynaptic action. J Neurol Neurosurg Psychiatry 56: 515–519
Becher JG, Lankhorst GJ, van Bennekom CA, Vogelaar TW (1999) Measurement of the effect of a bolus dose of intrathecal baclofen by a repetitive movement test. J Neurol 246: 1080–1085
Christie A, Lester S, LaPierre D, Gabriel DA (2004) Reliability of a new measure of H-reflex excitability. Clin Neurophysiol 115: 116–123
Dachy B, Dan B (2002) Electrophysiological assessment of the effect of intrathecal baclofen in spastic children. Clin Neurophysiol 113: 336–340
Dawes WJ, Drake JM, Fehlings D (2003) Microfracture of a baclofen pump catheter with intermittent under-and overdose. Pediatr Neurosurg 39: 144–148
Detrembleur C, Plaghki L (2000) Quantitative assessment of intrathecally administered baclofen in spasticity. Arch Phys Med Rehabil 81: 279–284
Galiana L, Fung J, Kearney R (2005) Identification of intrinsic and reflex ankle stiffness components in stroke patients. Exp Brain Res 165: 422–434
Latash ML, Penn RD, Corcos DM, Gottlieb GL (1989) Short-term effects of intrathecal baclofen in spasticity. Exp Neurol 103: 165–172
Lazorthes Y, Sallerin-Caute B, Verdie JC, Bastide R, Carillo JP (1990) Chronic intrathecal baclofen administration for control of severe spasticity. J Neurosurg 72: 393–402
Levin MF, Hui-Chan C (1993) Are H and stretch reflexes in hemiparesis reproducible and correlated with spasticity? J Neurol 240: 63–71
Lew SM, Psaty EL, Abbott R (2005) An unusual cause of overdose after baclofen pump implantation: case report. Neurosurgery 56: E624
Lexell JE, Downham DY (2005) How to assess the reliability of measurements in rehabilitation. Am J Phys Med Rehabil 84: 719–723
Macdonell RA, Talalla A, Swash M, Grundy D (1989) Intrathecal baclofen and the H-reflex. J Neurol Neurosurg Psychiatry 52: 1110–1112
Misiaszek JE (2003) The H-reflex as a tool in neurophysiology: its limitations and uses in understanding nervous system function. Muscle Nerve 28: 144–160
Morris S (2002) Ashworth and Tardieu scales: their clinical relevance for measuring spasticity in adult and paediatric neurological populations. Physical Therapy Reviews 7: 53–62
Nielsen JF, Hansen HJ, Sunde N, Christensen JJ (2002) Evidence of tolerance to baclofen in treatment of severe spasticity with intrathecal baclofen. Clin Neurol Neurosurg 104: 142–145
Nielsen JF, Sinkjaer T (1996) A comparison of clinical and laboratory measures of spasticity. Mult Scler 1: 296–301
Orsnes G, Crone C, Krarup C, Petersen N, Nielsen J (2000) The effect of baclofen on the transmission in spinal pathways in spastic multiple sclerosis patients. Clin Neurophysiol 111: 1372–1379
Pandyan AD, Johnson GR, Price CI, Curless RH, Barnes MP, Rodgers H (1999) A review of the properties and limitations of the Ashworth and modified Ashworth scales as measures of spasticity. Clin Rehabil 13: 373–383
Pohl M, Rockstroh G, Ruckriem S, Mehrholz J, Pause M, Koch R, Strik H (2003) Time course of the effect of a bolus dose of intrathecal baclofen on severe cerebral spasticity. J Neurol 250: 1195–1200
Sallerin-Caute B, Lazorthes Y, Monsarrat B, Cros J, Bastide R (1991) CSF baclofen levels after intrathecal administration in severe spasticity. Eur J Clin Pharmacol 40: 363–365
Schurch B (1993) Errors and limitations of the multimodality checking methods of defective spinal intrathecal pump systems. Case report. Paraplegia 31: 611–615
Sinkjaer T, Magnussen I (1994) Passive, intrinsic and reflex-mediated stiffness in the ankle extensors of hemiparetic patients. Brain 117: 355–363
Soni BM, Mani RM, Oo T, Vaidyanathan S (2003) Treatment of spasticity in a spinal cord-injured patient with intrathecal morphine due to intrathecal baclofen tolerance-a case report and review of literature. Spinal Cord 41: 586–589
Stokic DS, Yablon SA, Hayes A (2005) Comparison of clinical and neurophysiologic responses to intrathecal baclofen bolus administration in moderate-to-severe spasticity after acquired brain injury. Arch Phys Med Rehabil 86: 1801–1806
Stokic DS, Yablon SA, Hayes A, Vesovic-Potic V, Olivier J (2006) Dose-response relationship between the H-reflex and continuous intrathecal baclofen administration for anagement of spasticity. Clin Neurophysiol 117: 1283–1289
Uyttenboogaart M, Stewart RE, Vroomen PC, De Keyser J, Luijckx GJ (2005) Optimizing cutoff scores for the Barthel index and the modified Rankin scale for defining outcome in acute stroke trials. Stroke 36: 1984–1987
Yablon SA, Stokic DS (2004) Neurophysiologic evaluation of spastic hypertonia: implications for management of the patient with the intrathecal baclofen pump. Am J Phys Med Rehabil 83: S10–S18
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag
About this chapter
Cite this chapter
Stokic, D.S., Yablon, S.A. (2007). Neurophysiological basis and clinical applications of the H-reflex as an adjunct for evaluating response to intrathecal baclofen for spasticity. In: Sakas, D.E., Simpson, B.A., Krames, E.S. (eds) Operative Neuromodulation. Acta Neurochirurgica Supplements, vol 97/1. Springer, Vienna. https://doi.org/10.1007/978-3-211-33079-1_32
Download citation
DOI: https://doi.org/10.1007/978-3-211-33079-1_32
Publisher Name: Springer, Vienna
Print ISBN: 978-3-211-33078-4
Online ISBN: 978-3-211-33079-1
eBook Packages: MedicineMedicine (R0)