Summary
Integrated and miniaturized biosensor arrays were developed exhibiting outstanding performance. Biosensors with negligible sensitivity to interferences and high long-term stability were produced by modifying electrochemical transducers and utilizing photopatternable enzyme membranes. The use of appropriate miniaturization technology leads to mass producible devices for in vivo and ex vivo applications.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Astrup, J., Symon, L., Branston, N. and Lassen, N. (1977) Stroke 8: 51.
Bilitewski, U. (1992) In: G. Costa and S. Miertus (eds): Trends in electrochemical Biosensors World Scientific, Singapore, pp 59–68.
Gleise, R., Adams, J.M., Barone, N.J. and Yacynych, A.M. (1991) Biosens. Bioelectron. 6: 151–160.
Hanazato, Y., Nakako, M., Satorus, S. and Mitsuo, M. (1989) IEEE Trans. Electron. Dev. 36: 7, 1303–1310.
Hintsche, R., Dransfeld, I., Scheller, E, Pham, M., Hoffmann, W, Hueller, J. and Moritz, W (1990) Biosens. Bioelectron. 5: 327–334.
Jeyanthi, R. and Rao Panduranga, R. (1990) Biomaterials 11: 238–243.
Kimura, J., Kawana, Y. and Kuriyama, T. (1988) Biosensors 4: 41–52.
Margules, G.S., Hunter, C.M. and MacGregor, D.C. (1983) Med. Biol. Eng. Comput. 21: 1–8.
Mastrototaro, J., Johnson, K., Morff, R., Lipson, D., Andrew, C. Allen, D. (1991) Sensor. Actuator. B 1–4: 139–145.
Matthews, D., Holman, R., Streemson, J., Watson, A. and Hughes, S. (1987) Lancet 778.
Murakami, T., Nakamoto, S., Kimura, J., Kuriyama, T. and Karube, I. (1986) Anal. Lett. 19: 1973–1986.
Shiono, S., Hanazato, Y. and Nakako, M. (1986) Anal. Sci. 2: 517–521.
Strang, R.H.C. and Bachelard, H.S. (1973) J. Neurochem. 20: 987.
Tamiya, E., Karube, I., Hattori, S., Suzuki, M. and Yokoyama, K. (1989) Sensor Actuator B 18: 297–307.
Urban, G., Jobst, G., Keplinger, E, Aschauer, E., Tilado, O., Fasching, R. and Kohl, E (1992) Biosens. Bioelectron. 7: 733–739.
Urban, G., Jobst, G., Aschauer, E., Tilado, O., Svasek, P. and Varahram, M. (1994a) Performance of integrated glucose and lectate thin film microbiosensors for clinical analyzers. Sensor. Actuator. B 1–3: 592–596.
Urban, G., Jobst, G., Svasek, P., Varahram, M., Moser, I. and Aschauer, E. (1994b) Development of a micro flow-system with integrated biosensor array. MESA Monographs, Micro Total Analysis System, Univ, Twente, p 249.
Wilke, D. and Müller, H. (1992) In: G. Costa and S. Miertus (eds) Trends in electrochemical Biosensors. World Scientific: Singapore, pp 155–162.
Yokoyama, K., Sode, K., Tamiya, E. and Karube, I. (1989) Anal. Chim. Acta 218: 137–142.
Zhang, Y, Bindra, D.S., Barrau, M.B. and Wilson, S. (1991) Biosens. Bioelectron. 6: 653–661.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1997 Birkhäuser Verlag Basel/Switzerland
About this chapter
Cite this chapter
Urban, G.A., Jobst, G. (1997). Biosensors with modified electrodes for in vivo and ex vivo applications. In: Scheller, F.W., Schubert, F., Fedrowitz, J. (eds) Frontiers in Biosensorics II. EXS, vol 81. Birkhäuser Basel. https://doi.org/10.1007/978-3-0348-9045-8_12
Download citation
DOI: https://doi.org/10.1007/978-3-0348-9045-8_12
Publisher Name: Birkhäuser Basel
Print ISBN: 978-3-0348-9884-3
Online ISBN: 978-3-0348-9045-8
eBook Packages: Springer Book Archive