Skip to main content

Part of the book series: Biomethods ((BIOMETHODS))

  • 215 Accesses

Abstract

Patience Clever was disappointed. She looked at the result of the round robin test and admitted that the value they had reported was far from the mean value and outside of the confidence range. They had failed the test although they had done their method development and analysis very carefully. She looked through the protocols once more and recapitulated: we standardized with an acidified Se4+ solution in the range of 5–25 μ/L (0.15 ng-0.75 ng). Our calculated detection limit was about 1 μ/L in the solution for measurement and 3 μ/L based on undiluted serum. We stabilized Se with a Cu modifier which had already worked perfectly for many determinations in water samples. We even tried a mixture of Cu and Fe for comparison. The serum was diluted 1 + 2, 15 μL of the measurement solution were introduced into the tube and 10 μL of the modifier were added. The sample was pyrolyzed carefully at 1000 °C. Se was atomized at 2100 °C, giving a good symmetric peak which returned to the baseline after 2 s. The diluted serum measurement gave an average reading of 20 μ/L (0.3 ng) with a precision of 3–5%. Standards with concentrations of 3.3, 6.6 and 16.6 μ/L were added to the serum and yielded a line with exactly the same slope as that for the aqueous calibration (the calibration graphs are displayed in Fig. 2.1). The extrapolated value was again 20 μ/L (0.3 ng). Nevertheless, the true concentration of Se in the serum was 90 μ/L rather than 60 μ/L. Patience sighed What did we do wrong? After all this effort in calibration and checking an error is impossible! Why did the other labs get the right result? “One should invent a technique where you do the measurement on a sample and calculate the concentration in the sample just from physical constants; a kind of absolute analysis” and with a frown she grabbed the telephone to call the support desk of the instrument manufacturer.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Slavin W, Carnrick GR (1984)Spectrochim Acta 39B: 271.

    Google Scholar 

  2. Lawrence CH (1990) Modern Data Analysis, a First Course in Applied Statistics. Brooks/Cole, Belmont CA

    Google Scholar 

  3. Ellison S, Wegscheider W, Williams A (1997) Anal Chem 69: 607A.

    Article  CAS  Google Scholar 

  4. Perkin-Elmer publication (1996) # B050–4269. Bodenseewerk Perkin-Elmer GmbH, Überlingen, Germany.

    Google Scholar 

  5. Schlemmer G (1996) Atom Spectrosc 17: 15.

    CAS  Google Scholar 

  6. Mocak J, Bonde AM, Mitchell S,Scollary G (1997) Pure Appl Chem 69: 297.

    Article  CAS  Google Scholar 

  7. Ringbom AZ (1939) Z Anal Chem 115: 332.

    CAS  Google Scholar 

  8. de Loos-Vollebregt MTC, Koot JP,Padmos J (1989) J Anal Atom Spectrom 4: 387.

    Article  Google Scholar 

  9. de Galan L, van Dalen JPJ, KornblumGR (1985) Analyst 110: 323.

    Article  Google Scholar 

  10. L’vov BV, Polzik LK, Fedorov PN,Slavin W (1992) Spectrochim Acta 47B: 1411.

    Article  Google Scholar 

  11. L’vov BV, Polzik LK, Novichikhin PN,Fedorov PN, Borodin AV (1993) Spectrochim Acta 48B: 1625.

    Article  Google Scholar 

  12. Barnett WB (1984) Spectrochim Acta 39B: 829.

    Article  Google Scholar 

  13. Welz B (1986) ZAnal Chem 325: 95.

    CAS  Google Scholar 

  14. Slavin W, Carnrick GR (1986) Atom Spectrosc 7: 9.

    CAS  Google Scholar 

  15. de Loos-Vollebregt MTC, de Galan L (1978) Spectrochim Acta 33B: 495.

    Article  Google Scholar 

  16. de Loos-Vollebregt MTC, de Galan L (1980) Spectrochim Acta 35B: 495.

    Article  Google Scholar 

  17. de Loos-Vollebregt MTC, de Galan L (1982) Spectrochim Acta 37B: 659.

    Article  Google Scholar 

  18. Slavin W, Manning DC (1980) Spectrochim Acta 35B: 701.

    Article  Google Scholar 

  19. Slavin W, Manning DC (1979) Anal Chem 51: 261.

    Article  CAS  Google Scholar 

  20. Slavin W, Manning DC, Carnrick GR (1981) Atom Spectrosc 2: 137.

    CAS  Google Scholar 

  21. Welz B, Melcher M, Schlemmer G(1983) ZAnal Chem. 316: 271.

    Google Scholar 

  22. Welz B, Melcher M, Schlemmer G (1984) In: P Brätter, P Schramel (eds) Trace Element — Analytical Chemistry in Medicine and Biology, Vol. 3, Walter de Gruyter Co. Berlin.

    Google Scholar 

  23. Kleiner J, Lernhardt U (1994) SoftwareTools for Statisical Quality Control of Analytical Data, Proposal Eurolab Meeting.

    Google Scholar 

  24. Fuerstenwald-Vogl R (1997) CLB Chem Labor Biotech 48: 5.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1999 Birkhäuser Verlag Basel/Switzerland

About this chapter

Cite this chapter

Schlemmer, G., Radziuk, B. (1999). Important terms and units for analytical atomic spectrometry. In: Analytical Graphite Furnace Atomic Absorption Spectrometry. Biomethods. Birkhäuser Basel. https://doi.org/10.1007/978-3-0348-7576-9_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-0348-7576-9_2

  • Publisher Name: Birkhäuser Basel

  • Print ISBN: 978-3-0348-7578-3

  • Online ISBN: 978-3-0348-7576-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics