Abstract
Radiopharmaceuticals when prepared properly can provide key information in the diagnosis and treatment of patients. It is essential that the correct testing be performed to ensure not only safety but efficacy of the study. This chapter provides an overview of the criteria that must be evaluated when confirming a radiopharmaceutical meets the appropriate standards. While this chapter is not an all-inclusive for quality control analysis, it provides the reader an insight to the rationale and process for quality control and quality assurance testing.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
https://online.uspnf.com/uspnf/document/GUID-ED624F74-B941-4145-829-BA3765CD3E80_2_en-US. Accessed Jan 2019.
https://www.nrc.gov/reading-rm/doc-collections/cfr/part035/part035-0204.html. Accessed Nov 2018.
Ultra-Technekowâ„¢ V4 [package insert]. Maryland Heights, MO: Mallinckrodtâ„¢ Pharmaceuticals; 2015.
TechneLite® [package insert]. N Bilerica, MA: Lantheus Medical Imaging; 2018.
Radiogenix® System [package insert]. Beloit, WI: NorthStar Medical Radioisotopes LLC; 2020.
USP Monograph for Sodium Pertechnetate Tc 99m Injection; 2018.
Lamson MIII, Hotte CE, Ice RD. Practical generator kinetics. J Nucl Med Technol. 1976;4(1):21–7.
Hung JC, et al. Radiopharmaceutical-related pitfalls and artifacts. Semin Nucl Med. 1996;26(4):208–55.
Robbins PJ. Chromatography of technetium-99m radiopharmaceuticals—a practical guide. New York: The Society of Nuclear Medicine; 1984.
Waters Corporation. Certified Sep-Pak cartridges: care and use manual. Milford, MA: Author; 2009.
Technescan MAG3â„¢ [package insert]. Maryland Heights, MO: Mallinckrodtâ„¢ Pharmaceuticals; 2015.
Octreoscanâ„¢ [package insert]. Maryland Heights, MO: Mallinckrodtâ„¢ Pharmaceuticals; 2015.
Seetharaman S, Ballinger JR, Sosabowski MH. Simplified method for determining the radiochemical purity of 99mTc-MAG3. J Nucl Med Technol. 2006;34:179–83.
Ensing GJ, Knight HH. 99TCm-MAG3: problems with radiochemical purity testing [Letter to the editor]. Nucl Med Commun. 2001;22:114–5.
Ponto JA. Effect of solvent flow rate in mini-column testing of 99mTc-mertiatide. J Nucl Med Technol. 2005;33:232–3.
Saha GB. Quality control of radiopharmaceuticals. In: Saha GB, editor. Fundamentals of nuclear pharmacy. 7th ed. Cham: Springer; 2018. p. 163–83.
Technetium Tc-99m Sestamibi injection [package insert]. New York: Drax Image®; 2009.
Ceretecâ„¢ [package insert]. Arlington Heights, IL: GE Healthcare Medi-Physics, Inc.; 2018.
Lymphoseek [package insert]. Dublin, OH: Cardinal Health 414, LLC; 2019.
Neurolite® [package insert]. N. Billerica, MA: Lantheus Medical Imaging; 2015.
Zimmer AM, Spies SM. Quality control procedures for newer radiopharmaceuticals. J Nucl Med Technol. 19, 4:210–4.
Métayé T, et al. Rapid quality control for testing the radiochemical purity of 99Tcm tetrofosmin. Nucl Med Commun. 2001;22:1139–44.
McKay BF, et al. Rapid miniaturized chromatography for tecnetium-99m-tetrofosmin. J Nucl Med Technol. 1997;25:52–4.
Harapanhalli R. Food and Drug Administration requirements for testing and approval of new radiopharmaceuticals. Semin Nucl Med. 2010;40:364–84.
https://www.fda.gov/Drugs/DevelopmentApproval Process/HowDrugsareDevelopedandApproved/ApprovalApplications/InvestigationalNewDrugINDApplication/default.htm. Accessed Sep 18 2018.
https://www.ecfr.gov/cgi-bin/text-idx?SID=f640d0676f0a5f413cc184565e4724fc&mc=true&tpl=/ecfrbrowse/Title21/21cfr312_main_02.tpl. Accessed 31 Dec 2018.
http://www.fda.gov/ForPatients/ClinicalTrials/Types/default.htm. Accessed Dec 2018.
Saha GB. Radiation regulations, protection, and uses. In: Saha GB, editor. Fundamentals of nuclear pharmacy. 7th ed. Cham: Springer; 2018. p. 221.
Loveless V. Quality control of compounded radiopharmaceuticals. University of New Mexico Health Science Center Pharmacy Continuing Education, vol. 15, Lesson 3; 2009.
Author information
Authors and Affiliations
Corresponding authors
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Loveless, V., Morgan, S.H. (2021). Quality Assurance and Quality Control of Tc-99m Radiopharmaceuticals. In: Khalil, M.M. (eds) Basic Sciences of Nuclear Medicine. Springer, Cham. https://doi.org/10.1007/978-3-030-65245-6_6
Download citation
DOI: https://doi.org/10.1007/978-3-030-65245-6_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-65244-9
Online ISBN: 978-3-030-65245-6