Abstract

Breathing or external respiration is based on the expansion and contraction of the lungs. This mechanical activity can be picked up at appropriate locations on the surface of the skin by a laser Doppler vibrometer. To extract the breathing signal from the raw vibrometer signal, a low-pass filter is required since the bandwidth of the breathing signal is limited to an upper frequency which is below the range of the heartbeat activity. Because of its low distortion, a liner-phase FIR filter is used with an order high enough to suppress the influence of the heartbeat. There are several possibilities to calculate the breathing frequency on the basis of the low-pass filtered vibrometer signal in the frequency and time domain, respectively. The filtered signal is cut into data blocks of fixed length within which the estimation of the breathing frequency is executed. Customarily this frequency with the unit Hz which is identical with the respiration frequency measured in the unit breaths per minute or bpm. Thanks to the overlapping of the processed data blocks every second a new value of the respiration rate is calculated. To achieve a high resolution and a parameter independent implementation, the averaged zero-crossing method and the FFT method with zero-padding is preferred. But also the estimation based on the autocorrelation function is investigated because of its noise resistance based on the inherent averaging. Besides the respiration signal, the ventilation, i.e., the inhalation and exhalation is of interest which can be derived from the route signal of the measurement point. The route signal is the integral of the vibrometer signal which is a speed signal. The breathing can be measured on the thorax, i.e., closest to the lungs, but also at the neck or at other appropriate locations. This has the advantage that the neck normally is not covered by clothes since the laser signal penetrates only just a thin cover of cloth. The new approach is finally evaluated under the aspect of clinical applicability and the need for further investigations.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Carlton, P., Birrenkott, D.A., Bonnici, T., Pimentel, M.A., Johnson, A.E., Alastruey, J., Tarassenco, L., Watkinson, P.J., Beale, R., Clifton, D.A.: Breating rate estimation from the electrocardiogram and photoplephysmogram: a review. IEEE Rev. Biom. Eng. 1 (2018). https://doi.org/10.1109/rbme.2017.276281

  2. Demirakca, S.: Respiratory emergergencies and airway management in children. Med. Klin. Intensivmed. Notfallmed. 110(5), 328–337 (2015)

    Article  Google Scholar 

  3. Hogan, H., Healey, F., Neale, G., et al.: Preventable deaths due to problems in care in English acute hospitals: a retrospective case record review study. BMJ Qual. Saf. 22(2), 182 (2013)

    Article  Google Scholar 

  4. Kammeyer, K.-D., Kroschel, K.: Digitale Signalverarbeitung. Springer, Wiesbaden (2018)

    Book  Google Scholar 

  5. Kroschel, K., Rigoll, G., Schuller, B.: Statistische Informationstechnik. Springer, Heidelberg (2011)

    Book  Google Scholar 

  6. Lindh, W.Q., Pooler, M., Tamparo, C., Dahl, B.M.: Delmar’s comprehensive medical assisting: administrative and clinical competencies. Cengage Learning, p. 573, ISBN 978-1-4354-1914-8 (2009)

    Google Scholar 

  7. Lovett, P.B., Buchwald, J.M., Sturmann, K., Bijur, P.: The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann. Emerg. Med. 45, 68–76 (2005)

    Article  Google Scholar 

  8. Marchionni, P., Scalise, L., Ercoli, I., Tomasini, E.P.: An optical measurement method for the simultaneous assessment of respiration and heart rates in preterm infants. Rev. Sci. Instrum. 84(12), 121705 (2013)

    Article  ADS  Google Scholar 

  9. Nicolò, A., Massaroni, C., Passfield, L.: Respirattory frequency dring exercise: the neglected physiological measure. Front. Physiol. 8, 922 (2017)

    Article  Google Scholar 

  10. Philip, K.E., Pack, E., Cambiano, V., Rollmann, H., Weil, S., O’Beirne, J.: The accuracy of resiratory rate assessment by doctors in a London teaching hospital: a cross-sectional study. J. Clin. Monit. Comput. 29(4), 455–460 (2015)

    Article  Google Scholar 

  11. Shah, S.A., Fleming, S., Thompson, M., Tarassenko, L.: Respiratory rate estimation during triage of children in hospitals. Med. Eng. Technol. 39(8), 514–524 (2015)

    Article  Google Scholar 

  12. Wijdicks, E.F.: Biots’s breathing. J. Neurol. Psychiatr. 76(5), 512–513 (2007). https://doi.org/10.1163/jnnp.2006.104919

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kristian Kroschel .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Kroschel, K., Demirakca, S. (2020). Parameters of Respiration. In: Kroschel, K. (eds) Laser Doppler Vibrometry for Non-Contact Diagnostics. Bioanalysis, vol 9. Springer, Cham. https://doi.org/10.1007/978-3-030-46691-6_4

Download citation

Publish with us

Policies and ethics