Skip to main content

Diagnostics of Electrical Connections of Electric Traction Network

  • Conference paper
  • First Online:
Book cover VIII International Scientific Siberian Transport Forum (TransSiberia 2019)

Abstract

Full-scale structural measurements of new and existing electric traction networks are becoming increasingly important because of the ever-increasing train speeds and associated effects. Higher speeds lead to increased loads and greater structural dynamic responses, increasing mechanical and electrical loads. Electrical contact connections are an integral part of the electric traction network: under operating conditions, the electrical installation circuit in many cases should allow to separate the elements from each other. At the same time, electrical contacts are a weak component in energy distribution systems, since the occurrence of large transient resistances in the contact area is one of the most common cases leading to heating of the connection and breakage of the catenary. The purpose of the work is to improve the performance reliability and prevent damage to the electric traction network by reducing the complexity of servicing bolted electrical connections through the development and mass implementation of visual diagnostics. The main parameter characterizing the bolted electrical connection is its resistance, the value of which depends on two interrelated factors: parameters of the contacting surfaces and the contact force. Research of thermal processes in the contact connection and determination of its performance characteristics allow to create a method of diagnosis of the state of the electrical connection on the basis of new methods using modern equipment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Grigor’ev, N., Voprikov, A., Parfianovich, A.: Increasing the operating life of power transformer winding insulation when upgrading 25-kV alternating current traction substations. Russ. Electr. Eng. 87(2), 100–103 (2016). https://doi.org/10.3103/S1068371216020048

    Article  Google Scholar 

  2. Li, V., Shnurova, N.: On the method of determining optimal electricity consumption from an electric traction network. Russ. Electr. Eng. 87(2), 97–99 (2016). https://doi.org/10.3103/S1068371216020127

    Article  Google Scholar 

  3. Li, V., Klimenko, S.: Determination of thermal softening of overhead wire exposed to an electric arc effect. Russ. Electr. Eng. 87(2), 77–79 (2016). https://doi.org/10.3103/S1068371216020115

    Article  Google Scholar 

  4. Xin, Z., Schoepf, T.: Detection and formation process of overheated electrical joints due to faulty connections. In: 26th International Conference on Electrical Contacts (ICEC), p. 12909251 (2012). https://doi.org/10.1049/cp.2012.0663

  5. Ignatenko, I., Vlasenko, S.: Determination of criteria to find the quality of an electrical connection. Russ. Electr. Eng. 87(2), 65–67 (2016). https://doi.org/10.3103/S1068371216020085

    Article  Google Scholar 

  6. Wilson, C., McIntosh, G.; Timsit, R.S.: Contact spot temperature and the temperature of external surfaces in an electrical connection. In: 26th International Conference on Electrical Contacts (ICEC), p. 12909202 (2012). https://doi.org/10.1049/cp.2012.0614

  7. Bukhanov, S., Doykina, L., Tsirkunenko, A.: Evaluation of the electromagnetic situation at open switchgears of power stations and substations. In: IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus), p. 18508901 (2019). https://doi.org/10.1109/eiconrus.2019.8656642

  8. Tryapkin, E., Keino, M., Protasov, F.: Synchronous phase measurements in the automated monitoring system of railway power supply facilities. Russ. Electr. Eng. 87(2), 110–112 (2016). https://doi.org/10.3103/S1068371216020176

    Article  Google Scholar 

  9. Grigor’ev, N., Klykov, M., Parfianovich, A., Shestukhina, V.: Increasing the power efficiency of a 25-kv alternating current traction power supply system. Russ. Electr. Eng. 87(2), 113–115 (2016). https://doi.org/10.3103/S106837121602005X

    Article  Google Scholar 

  10. Konstantinova, Y., Li, V., Tryapkin, E.: Enhancing Energy Efficiency of 25 kV Traction power system due to balancing current decrease. In: International Multi-conference on Industrial Engineering and Modern Technologies (FarEastCon), p. 18393188 (2018). https://doi.org/10.1109/fareastcon.2018.8602632

  11. Galkin, A., Kovalev, A., Shayukhov, T.: Integrated approach to the planning of energy consumption by non-traction railway consumers. In: MATEC, vol. 239, p. 01056 (2018). https://doi.org/10.1051/matecconf/201823901056

    Article  Google Scholar 

  12. Tumanov, A., Gumenyuk, V., Tumanov, V.: Development of advanced mathematical predictive models for assessing damage avoided accidents on potentially-dangerous sea-based energy facility. In: IOP Conference Series: Earth and Environmental Science (EMMFT 2017), vol. 90, p. 012027 (2017). https://doi.org/10.1088/1755-1315/90/1/012027

    Article  Google Scholar 

  13. Bukhanov, S., Zhuravleva, L., Kornienko, M.: Improving the reliability of the relay automation system for power facilities. In: IOP Conference Series: Materials Science Engineering, vol. 450, p. 072008 (2018). https://doi.org/10.1088/1757-899x/450/7/072008

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ivan Ignatenko .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Ignatenko, I., Vlasenko, S. (2020). Diagnostics of Electrical Connections of Electric Traction Network. In: Popovic, Z., Manakov, A., Breskich, V. (eds) VIII International Scientific Siberian Transport Forum. TransSiberia 2019. Advances in Intelligent Systems and Computing, vol 1115. Springer, Cham. https://doi.org/10.1007/978-3-030-37916-2_8

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-37916-2_8

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-37915-5

  • Online ISBN: 978-3-030-37916-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics