Abstract

An extremely compact gated integrator prototype has been realized and preliminarily characterized. Front-end section of the circuit is based on the high precision integrator IVC102, whereas the analog to digital conversion and data-acquisition, as well as the timing control, are performed by an LCP845 microcontroller. The system synchronizes signal detection with an external trigger generated in coincidence with the source pulse, i.e. the gated integrator amplifies the signal only when a pulse is generated, increasing significantly the signal-to-noise ratio. As a consequence, the proposed circuitry would represent an affordable, sensitive, and cost-effective alternative to the continuous-time regime measurement-technique largely adopted, for example, in radiation dosimetry.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Bucciolini M et al (2003) Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size. Med Phys 30(8):2149–2154

    Article  Google Scholar 

  2. Tromson D et al (2010) Single crystal CVD diamond detector for high resolution dose measurement for IMRT and novel radiation therapy needs. Diam Relat Mater 19:1012–1016

    Article  ADS  Google Scholar 

  3. Marsolat F et al (2013) Diamond dosimeter for small beam stereotactic radiotherapy. Diam Relat Mater 33:63–70

    Article  ADS  Google Scholar 

  4. Girolami M et al (2012) Diamond detectors for UV and X-ray source imaging. IEEE Electron Device Lett 33:224–226

    Article  ADS  Google Scholar 

  5. Girolami M et al (2012) Optimization of X-ray beam profilers based on CVD diamond detectors. J Instrum 7:C11005

    Article  Google Scholar 

  6. Conte G et al (2007) X-ray diamond detectors with energy resolution. Appl Phys Lett 91:183515

    Article  ADS  Google Scholar 

  7. Salvatori S et al (2017) Nano-carbon pixels array for ionizing particles monitoring. Diamo Relat Mater 73:132–136

    Article  ADS  Google Scholar 

  8. Pacilli M et al (2012) Polycrystalline CVD diamond pixel array detector for nuclear particles monitoring. J Instrum 8:C02043

    Article  Google Scholar 

  9. Muraro A et al (2016) First neutron spectroscopy measurements with a pixelated diamond detector at JET. Rev Sci Instrum 87:11D833

    Article  Google Scholar 

  10. D’Antonio E et al (2018) High precision integrator for CVD-diamond detectors for dosimetric applications. In: 2018 IEEE international symposium on medical measurements and applications (MeMeA), pp 1–6

    Google Scholar 

  11. See for example https://www.ptwdosimetry.com/en/products/unidos-webline/

  12. Khan FM, Gibbons JP (2014) Khan’s the physics of radiation therapy. Lippincott Williams & Wilkins, Philadelphia

    Google Scholar 

  13. Reichert J, Townsend J (1964) Gated integrator for repetitive signals. Rev Sci Instrum 35:1692–1697

    Article  ADS  Google Scholar 

  14. Betts J (1970) Signal processing, modulation and noise. English Universities Press, London

    Google Scholar 

  15. Collier JL et al (1996) A low-cost gated integrator boxcar averager. Meas Sci Technol 7:1204

    Article  ADS  Google Scholar 

  16. See for example ClinacR iX System, Varian Medical Systems, Inc., CA (USA). https://www.varian.com/oncology/products/treatment-delivery/clinac-ix-system

  17. Precision switched integrator transimpedance amplifier, IVC102, datasheet, Texas Instruments. www.ti.com/lit/ds/symlink/ivc102.pdf

  18. Salvatori S et al (2006) Compact front-end electronics for low-level current sensor measurements. Electron Lett 42:682–684

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Marco Pacilli and Fabrizio Imperiali for fruitful discussions and technical support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sara Pettinato .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Pettinato, S., Orsini, A., Rossi, M.C., Tagnani, D., Girolami, M., Salvatori, S. (2020). A Compact Gated Integrator for Conditioning Pulsed Analog Signals. In: Saponara, S., De Gloria, A. (eds) Applications in Electronics Pervading Industry, Environment and Society. ApplePies 2019. Lecture Notes in Electrical Engineering, vol 627. Springer, Cham. https://doi.org/10.1007/978-3-030-37277-4_5

Download citation

Publish with us

Policies and ethics