This paper presents the results of a study on the development of alumina-based porosity reference materials (RMs), which are intended for controlling the accuracy of the measurement results obtained using the mercury porosimetry method. These mercury porosimetry RMs are being developed in the Russian Federation for the first time and are primarily intended for verification/calibration and testing for type approval of mercury porosimeters. The study of metrological characteristics was conducted using a reference system, which is to be included in the GET 210-2014 State Primary Measurement Standard for units of specific gas adsorption, specific surface area, specific volume and pore size of solid substances and materials. This reference system was calibrated prior to conducting the study with the use of external reference pressure sensors of the 2nd order at 0.6 and 400 MPa, as well as a laboratory balance (special accuracy class I) having a maximum weighing limit of 220 g. In the course of conducted research work, procedures for reproducing and estimating the uncertainty of porosity characteristics using the mercury porosimetry method were developed. When estimating the RM metrological characteristics, the standard uncertainty, associated with the characterisation and heterogeneity of the studied materials (RM candidates), was evaluated. The standard uncertainty due to instability was disregarded due to the high stability of the alumina matrix. According to the results of the conducted studies, four types of alumina-based porosity RM were developed. Their pore sizes are in the region of ~10 nm; ~2,000 nm; ~9,000 nm; ~60,000 nm. The RMs with pore sizes of ~10 nm; ~2,000 nm were intended for use in controlling the accuracy of mercury porosimeters operating at high pressures, while the RMs with pore sizes of ~9,000 nm; ~60,000 nm were for controlling the accuracy of mercury porosimeters operating at low pressures. The developed RMs are different from their foreign counterparts, which are produced by BAM (Germany) and NIST (USA) metrological institutes. The standard uncertainty due to characterisation of the RMs in question was estimated, not by the method of interlaboratory experiment, but by a full analysis of the constraint equations taking into account all sources of uncertainty included in the equations on the basis of the Guide to the Expression of Uncertainty in Measurement. The conducted studies allowed the RM certified values to be traceable at this stage to the GET 3-2008 State Primary Measurement Standard for the mass unit (kilogram), the GET 101-2011 State Primary Measurement Standard for the pressure unit in the field of absolute pressure in the range 1 × 10−1–7 × 105 Pa, the GET 43-2013 State Primary Measurement Standard for the pressure unit in the range 10–1600 MPa and the effective area of the piston-cylinder unit of dead weight testers in the range 0.05–1 cm2. In addition, a reference material having a large pore size of ~60,000 nm, which currently has no analogues elsewhere in the world, was characterised.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Notes

  1. 1.

    The measurement limits of the LPC-2-6 and LPC-2-4000 pressure sensors used with the calibrator are 600 kPa and 400 MPa, with permissible absolute pressure fiducial error limits of ±0.025% and ±0.1%, respectively.

  2. 2.

    The optimal rate was determined via preliminary studies, the minimum standard deviation of results of measuring the dominant pore size being the optimality criterion.

  3. 3.

    Measurements are carried out for the empty dilatometer without a sample.

References

  1. Karnaukhov AP (1999) Adsorption. Texture of dispersed and porous materials. Nauka, SB RAS, Novosibirsk (in Russ.)

    Google Scholar 

  2. Fenelonov VB (2004) Introduction to the basics of adsorption and texturology. Publ. House of SB RAS, Novosibirsk (in Russ.)

    Google Scholar 

  3. Grek S, Sing K (1984) Absorption, specific surface, porosity. Moscow, Mir, (in Russ.)

    Google Scholar 

  4. GOST ISO Guide 35-2015 Reference materials. General and statistical principles for certification

    Google Scholar 

  5. BAM official website (2018) Reference Materials. Certificates and reports. https://rrr.bam.de/RRR/Navigation/EN/Reference-Materials/RM-Certificates-reports/Porous-RM/porous-rm.html. Accessed 3 Oct 2018

  6. NIST (2011) A certificate of analysis on the SRM 1918. Mercury porosimeter intrusion standard. https://www-s.nist.gov/srmors/certificates/1918.pdf. Accessed 03 Oct 2018

  7. Order of the Federal Agency for Technical Regulation and Metrology of January 29, 2015 No. 128. On approval of the national primary standard for the units of specific adsorption of gases, specific surface area, specific volume and pore size of solid substances and materials (in Russ.)

    Google Scholar 

  8. GSSSD 3-77 Mercury. Mercury density and the coefficient of thermal expansion at atmospheric pressure and temperatures from 0 to 350 ℃. Reference data tables

    Google Scholar 

  9. ISO 15901-1:2016 Evaluation of pore size distribution and porosity of solid materials by mercury porosimetry and gas adsorption—Part 1: Mercury porosimetry

    Google Scholar 

  10. Sobina EP (2016) Development of a Certified Standard Reference Sample of Nanoporous Aluminum Oxide. Meas Tech 8:68–72 (in Russ.)

    Google Scholar 

Download references

Conflict of Interest

One of the authors is a member of the Editorial Board of these proceedings.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Egor P. Sobina .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Sobina, E.P. (2020). Development of Alumina-Based Porosity Reference Materials for the Mercury Porosimetry Method. In: Medvedevskikh, S., Kremleva, O., Vasil’eva, I., Sobina, E. (eds) Reference Materials in Measurement and Technology. RMMT 2018. Springer, Cham. https://doi.org/10.1007/978-3-030-32534-3_10

Download citation

Publish with us

Policies and ethics