Abstract
A major limitation of current electronic retinal implants is that in addition to stimulating the intended retinal ganglion cells, they also stimulate passing axon fibers, producing perceptual ‘streaks’ that limit the quality of the generated visual experience. Recent evidence suggests a dependence between the shape of the elicited visual percept and the retinal location of the stimulating electrode. However, this knowledge has yet to be incorporated into the surgical placement of retinal implants. Here we systematically explored the space of possible implant configurations to make recommendations for optimal intraocular positioning of the electrode array. Using a psychophysically validated computational model, we demonstrate that better implant placement has the potential to reduce the spatial extent of axonal activation in existing implant users by up to \(\sim \)55%. Importantly, the best implant location, as inferred from a population of simulated virtual patients, is both surgically feasible and is relatively stable across individuals. This study is a first step towards the use of computer simulations in patient-specific planning of retinal implant surgery.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ahuja, A.K., Behrend, M.R.: The \({Argus}^{\text{TM}}\) II retinal prosthesis: factors affecting patient selection for implantation. Prog. Retinal Eye Res. 36, 1–23 (2013). https://doi.org/10.1016/j.preteyeres.2013.01.002
Beyeler, M., Boynton, G.M., Fine, I., Rokem, A.: pulse2percept: a Python-based simulation framework for bionic vision. In: Huff, K., Lippa, D., Niederhut, D., Pacer, M. (eds.) Proceedings of the 16th Science in Python Conference, pp. 81–88 (2017). https://doi.org/10.25080/shinma-7f4c6e7-00c
Beyeler, M.: Biophysical model of axonal stimulation in epiretinal visual prostheses. In: 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER), pp. 348–351 (2019). https://doi.org/10.1109/NER.2019.8716969
Beyeler, M., Nanduri, D., Weiland, J.D., Rokem, A., Boynton, G.M., Fine, I.: A model of ganglion axon pathways accounts for percepts elicited by retinal implants. Sci. R. 9(1), 9199 (2019). https://doi.org/10.1038/s41598-019-45416-4
Fine, I., Boynton, G.M.: Pulse trains to percepts: the challenge of creating a perceptually intelligible world with sight recovery technologies. Philos. Trans. R. Soc. Lond. B Biol. Sci. 370(1677), 20140208 (2015). https://doi.org/10.1098/rstb.2014.0208
Fried, S.I., Lasker, A.C.W., Desai, N.J., Eddington, D.K., Rizzo, J.F.: Axonal sodium-channel bands shape the response to electric stimulation in retinal ganglion cells. J. Neurophysiol. 101(4), 1972–1987 (2009). https://doi.org/10.1152/jn.91081.2008
Jansonius, N.M., et al.: A mathematical description of nerve fiber bundle trajectories and their variability in the human retina. Vis. Res. 49(17), 2157–2163 (2009). https://doi.org/10.1016/j.visres.2009.04.029
Luo, Y.H., Zhong, J.J., Clemo, M., da Cruz, L.: Long-term repeatability and reproducibility of phosphene characteristics in chronically implanted argus(R) II retinal prosthesis subjects. A. J. Ophthalmol. (2016). https://doi.org/10.1016/j.ajo.2016.07.021
Rachitskaya, A.V., Yuan, A., Marino, M.J., Reese, J., Ehlers, J.P.: Intraoperative OCT imaging of the argus II retinal prosthesis system. Ophthalmic Surg. Lasers Imaging Retina 47(11), 999–1003 (2016). https://doi.org/10.3928/23258160-20161031-03
Second Sight Medical Products: Argus II Retinal Prosthesis System Surgeon Manual (2013). https://www.accessdata.fda.gov/cdrh_docs/pdf11/h110002c.pdf
Weitz, A.C., et al.: Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration. Sci. Transl. Med. 7(318), 318ra203 (2015). https://doi.org/10.1126/scitranslmed.aac4877
Acknowledgments
Supported by the Washington Research Foundation Funds for Innovation in Neuroengineering and Data-Intensive Discovery (M.B.), by an award from the Gordon and Betty Moore Foundation (Award #2013-10-29) and the Alfred P. Sloan Foundation (Award #3835) to the University of Washington eScience Institute (A.R.), and by the National Institutes of Health (NIH K99 EY-029329 to M.B., EY-12925 to G.M.B., and EY-014645 to I.F.).Research credits for cloud computing were provided by Amazon Web Services.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Beyeler, M., Boynton, G.M., Fine, I., Rokem, A. (2019). Model-Based Recommendations for Optimal Surgical Placement of Epiretinal Implants. In: Shen, D., et al. Medical Image Computing and Computer Assisted Intervention – MICCAI 2019. MICCAI 2019. Lecture Notes in Computer Science(), vol 11768. Springer, Cham. https://doi.org/10.1007/978-3-030-32254-0_44
Download citation
DOI: https://doi.org/10.1007/978-3-030-32254-0_44
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-32253-3
Online ISBN: 978-3-030-32254-0
eBook Packages: Computer ScienceComputer Science (R0)