Abstract
Voxel-wise absorbed dose distributions, γ-index agreement test and dose-volume histograms (DVH) for the evaluation of dose distributions have been used in stereotactic body radiotherapy (SBRT) for several years. Our research group recently adapted these concepts to liver radioembolization (RE) using Yttrium-90 (90Y) glass microspheres (MS). In this work we demonstrate the application of our dosimetry tools to study the dose distributions within the tumor (PTV) and normal liver (NLV) tissues of a patient treated with multiple radiation therapies (RE after SBRT). Voxel-wise biological effective dose (BED) distributions from SBRT and RE were computed and added up. Moreover, we investigated the role of pre-treatment single-photon emission computed tomography (SPECT) in the planning dosimetry of RE.
This individual case describes a 73 years old man with pancreatic carcinoma and a single liver metastasis previously treated with 48 Gy of 10 MV SBRT photon beams in three sessions of 16 Gy. Ten months later he underwent RE due to disease progression. RE was performed according to the MS manufacturer’s recommendations. Hepatic arterial angiography and pre-treatment Technetium-99 m (99mTc) macroaggregated albumin (MAA) scans (planar and SPECT) were performed in preparation of RE. Then, a 90Y-MS activity of 3.239 GBq was calculated and later administered in the liver. 90Y-MS positron emission tomography (PET) images were then used to verify the distribution of the MS in the liver. SPECT-MAA and PET-MS images were used, retrospectively, to calculate the voxel-wise dose distributions. Voxel-wise BED distributions of SBRT and RE were computed and added up to obtain the total BED. Cumulative dose volume histograms (DVHs) were generated to evaluate the safety of multiple radiation therapies. Finally, the voxel-wise intraclass correlation coefficient (ICC) and γ-index between pre and post-treatment dose distributions were computed. The predictive power role of the pre-treatment SPECT-MAA in the planning dosimetry of RE after SBRT was further investigated. In conclusion, the previous SBRT treatment contributed significantly to the BED in the RE PTV with no detectable contribution to the BED in the RE NLV. Therefore, higher activity might have been administered during RE keeping the NLV dose at safe values. Moreover, the verification PET-MS dose distribution, in this individual case, showed good agreement with the pre-treatment SPECT-MAA dose distribution (ICC = 0.73, γ-index = 98%). Consequently, SPECT-MAA could have been used in the planning dosimetry of RE.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Lam, M.G.E.H., et al.: Safety of 90Y radioembolization in patients who have undergone previous external beam radiation therapy. Int. J. Radiat. Oncol. Biol. Phys. 87(2), 323–329 (2013)
Wang, T.-H., et al.: Combined Yttrium-90 microsphere selective internal radiation therapy and external beam radiotherapy in patients with hepatocellular carcinoma: from clinical aspects to dosimetry. PLoS ONE 13(1), 1–14 (2018)
Ferreira, P.: Voxel-based dosimetry using multimodal images for patient-specific liver ra-dioembolization with Yttrium-90 charged glass microspheres. Ph.D. thesis, Department of Electrical and Computer Engineering, Universidade de Lisboa (2019)
Fedorov, A., et al.: 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn. Reson. Imaging 30(9), 1323–1341 (2012)
Yushkevich, P.A., et al.: ITK-SNAP: an intractive medical image segmentation tool to meet the need for expert-guided segmentation of complex medical images. IEEE Pulse 8(4), 54–57 (2017)
Bolch, W.E., et al.: MIRD pamphlet no. 17: the dosimetry of nonuniform activity distributions–radionuclide S values at the voxel level. J. Nucl. Med. 40(1), 11–36 (1999). Medical Internal Radiation Dose Committee
Lanconelli, N., et al.: A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions. Phys. Med. Biol. 57(2), 517–533 (2012)
Cremonesi, M., et al.: Radioembolization of hepatic lesions from a radiobiology and dosimetric perspective. Front. Oncol. Rev. 4(210), 1–20 (2014)
Strigari, L., et al.: Dosimetry in nuclear medicine therapy: radiobiology application and results. Q. J. Nucl. Med. Mol. Imaging 55(2), 205–221 (2011)
Low, D.A., et al.: A technique for the quantitative evaluation of dose distributions. Med. Phys. 25(5), 656–661 (1998)
Acknowledgments
We gratefully acknowledge the dedicated contribution of the entire personal from Nuclear Medicine – Radiopharmacology, Interventional Imaging and Radiation-Oncology at the Champalimaud Centre for the Unknown, Champalimaud Foundation.
PF thankfully acknowledges the Champalimaud Foundation for a recurrent PhD student grant.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Ferreira, P. et al. (2019). Voxel-Based Computational Tools Help Liver Dosimetry Calculations of Multiple (External and Internal) Radiation Therapies. In: Tavares, J., Natal Jorge, R. (eds) VipIMAGE 2019. VipIMAGE 2019. Lecture Notes in Computational Vision and Biomechanics, vol 34. Springer, Cham. https://doi.org/10.1007/978-3-030-32040-9_22
Download citation
DOI: https://doi.org/10.1007/978-3-030-32040-9_22
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-32039-3
Online ISBN: 978-3-030-32040-9
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)