The Variation of Electric Field on the Conductor Surface Characterized by Space Charge Density

  • Conference paper
  • First Online:
Proceedings of the 21st International Symposium on High Voltage Engineering (ISH 2019)

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 598))

Included in the following conference series:

  • 2210 Accesses

Abstract

The accuracy of surface electric field (SEF) is important for the research of corona discharge phenomenon, both in numerical simulation and actual application. However, it is widely considered that the SEF is invariable after corona occurs (Kaptzov’s assumption). This theory makes corona study more convenient, but slightly inconsistent with the actual situation. In this work, SEF for the negative corona discharge in a coaxial cylinder’s model is investigated through the space charge density. Space charge density is measured by sound pulse method, which is a non-contact measurement method. It can avoid the introduction of interference in the study of SEF. By selecting the maximum charge density (charge density around the conductor) closely related to the SEF as the research objective, the variation of SEF intensity can be obtained. Results show that the values of charge density increase with the rise of applied voltage and the diameter of the conductor. Through the maximum charge density near the wire, the variation formula of SEF can be obtained. It shows that SEF is not a fixed value and not equal to the onset field intensity, and it has a decreasing trend with the applied voltage rising after corona initiates.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Zhou, Z., Cui, X., Lu, T.: Measurements of space charge density under HVDC conductor based on aspirator-type charge meter. High Voltage Eng. 42(9), 2962–2967 (2016)

    Google Scholar 

  2. Sun, H., Lu, B., Wang, M.: The role of photoionization in negative corona discharge: the influences of temperature, humidity, and air pressure on a corona. Phys. Plasmas 24(10), 103506 (2017)

    Article  Google Scholar 

  3. Modi, A., Koratkar, N., Lass, E.: Miniaturized gas ionization sensors using carbon nanotubes. Nature 424(6945), 171 (2003)

    Article  Google Scholar 

  4. Bussiahn, R., Brandenburg, R., Gerling, T.: The hairline plasma: an intermittent negative dc-corona discharge at atmospheric pressure for plasma medical applications. Appl. Phys. Lett. 96(14), 143701 (2010)

    Article  Google Scholar 

  5. Qiao, J., Zou, J., Li, B.: Calculation of the ionised field and the corona losses of high-voltage direct current transmission lines using a finite-difference-based flux tracing method. IET Gener. Transm. Distrib. 9(4), 348–357 (2015)

    Article  Google Scholar 

  6. He, W., He, J., Wan, B.: Influence of altitude on radio interference level of AC power lines based on corona cage. IET Sci. Measur. Technol. 9(7), 861–865 (2015)

    Article  Google Scholar 

  7. Li, X., Cui, X., Lu, T.: The correlation between audible noise and corona current in time domain caused by single positive corona source on the conductor. IEEE Trans. Dielectr. Electr. Insul. 22(2), 1314–1320 (2015)

    Article  Google Scholar 

  8. Maruvada, P.S.: Electric field and ion current environment of HVdc transmission lines: comparison of calculations and measurements. IEEE Trans. Power Deliv. 76(18), 4153–4159 (1971)

    Google Scholar 

  9. Zhang, B., Mo, J., Yin, H.: Calculation of ion flow field around HVdc bipolar transmission lines by method of characteristics. IEEE Trans. Magn. 51(3), 1–4 (2015)

    Google Scholar 

  10. Takuma, T., Ikeda, T., Kawamoto, T.: Calculation of ion flow fields of HVDC transmission lines by the finite element method. IEEE Trans. Power Apparatus Syst. PAS-100(12), 4802–4810 (1981)

    Article  Google Scholar 

  11. Bian, X., Yu, D., Meng, X.: Corona-generated space charge effects on electric field distribution for an indoor corona cage and a monopolar test line. IEEE Trans. Dielectr. Electr. Insul. 18(5), 1767–1778 (2011)

    Article  Google Scholar 

  12. Cladt, J.J., Gary, C.H.: Predetermination of corona losses under rain: experimental interpreting and checking of a method to calculate corona losses. IEEE Trans. Power Apparatus Syst. PAS-89(5), 853–860 (1970)

    Article  Google Scholar 

  13. Zhou, X., Cui, X., Lu, T.: A time-efficient method for the simulation of ion flow field of the AC-DC hybrid transmission lines. IEEE Trans. Magn. 48(2), 731–734 (2012)

    Article  Google Scholar 

  14. Penney, G.W., Hewitt, J.G.: Some measurements of abnormal corona. Trans. Am. Inst. Electr. Part I: Eng. Commun. Electron. 77(3), 319–327 (1958)

    Google Scholar 

  15. Penney, G.W., Matick, R.E.: Potentials in DC corona fields. Trans. Am. Inst. Electr. Part I: Eng. Commun. Electron. 79(2), 91–99 (1960)

    Google Scholar 

  16. Waters, R.T.: A cylindrical electrostatic flux meter for corona studies. J. Phys. E: Sci. Instrum. 5(5), 475 (1972)

    Article  Google Scholar 

  17. Liao, R., Liu, K., Liu, H., Wu, F.: Measurement of space charge in negative corona on a small corona cage. IEEE Trans. Dielectr. Electr. Insul. 23(4), 2344–2352 (2016)

    Article  Google Scholar 

  18. Zheng, Y., He, J., Zhang, B.: Surface electric field for negative corona discharge in atmospheric pressure air. IEEE Trans. Plasma Sci. 39(8), 1644–1652 (2011)

    Article  Google Scholar 

Download references

Acknowledgments

All the authors thank the National Basic Research Program of China (Grant No. 2011CB209401), National Natural Science Foundation of China (Grant No. 51877016), the National Key Research and Development Plan (2016YFB0900700) for the financial support provided and Professor Kazimierz Adamiak for his suggestions to the paper revision.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hongbo Liu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Liao, R., Liu, H., Zhao, X., Ren, L., Lin, Y. (2020). The Variation of Electric Field on the Conductor Surface Characterized by Space Charge Density. In: Németh, B. (eds) Proceedings of the 21st International Symposium on High Voltage Engineering. ISH 2019. Lecture Notes in Electrical Engineering, vol 598. Springer, Cham. https://doi.org/10.1007/978-3-030-31676-1_27

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-31676-1_27

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-31675-4

  • Online ISBN: 978-3-030-31676-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics