Abstract
Approaches based on hidden Markov models (HMMs) have been devoted particular attention in the last years. AFAMAP (Additive Factorial Approximate Maximum a Posteriori) has been introduced in Kolter and Jaakkola to reduce the computational burden of FHMM. The algorithm bases its operation on additive and difference FHMM, and it constrains the posterior probability to require only one HMM change state at any given time.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
G.W. Hart, Nonintrusive appliance load monitoring. Proc. IEEE 80(12), 1870–1891 (1992)
H. Kim, M. Marwah, M.F. Arlitt, G. Lyon, J. Han, Unsupervised disaggregation of low frequency power measurements, in Proceedings of the 11th SIAM International Conference on Data Mining, Mesa (2011), pp. 747–758
O. Parson, S. Ghosh, M. Weal, A. Rogers, An unsupervised training method for non-intrusive appliance load monitoring. Artif. Intell. 217, 1–19 (2014)
O. Parson, M. Weal, A. Rogers, A scalable non-intrusive load monitoring system for fridge-freezer energy efficiency estimation, in Proceedings of the 2nd International Workshop on Non-Intrusive Load Monitoring, Austin, Jun. 3 2014
A. Zoha, A. Gluhak, M. Nati, M.A. Imran, Low-power appliance monitoring using Factorial Hidden Markov Models, in Proceedings of the 8th International Conference on Intelligent Sensors, Sensor Networks and Information Processing: Sensing the Future (ISSNIP), Melbourne, vol. 1 (2013), pp. 527–532
J.Z. Kolter, T. Jaakkola, Approximate inference in additive factorial HMMs with application to energy disaggregation. J. Mach. Learn. Res. 22, 1472–1482 (2012)
I. Valera, F.J.R. Ruiz, F. Perez-Cruz, Infinite factorial unbounded-state hidden Markov model. IEEE Trans. Pattern Anal. Mach. Intell. 38(9), 1816–1828 (2016)
M. Zhong, N. Goddard, C. Sutton, Signal aggregate constraints in additive factorial HMMs with application to energy disaggregation, in Advances in Neural Information Processing Systems (2014), pp. 3590–3598
S. Makonin, F. Popowich, I.V. Bajić, B. Gill, L. Bartram, Exploiting HMM sparsity to perform online real-time nonintrusive load monitoring. IEEE Trans. Smart Grid 7(6), 2575–2584 (2016)
M.J. Johnson, A.S. Willsky, Bayesian nonparametric hidden semi-Markov models. J. Mach. Learn. Res. 14(1), 673–701 (2013)
J. Kelly, W. Knottenbelt, Neural NILM: deep neural networks applied to energy disaggregation, in Proceedings of the 2nd ACM International Conference on Embedded Systems for Energy-Efficient Built Environments, BuildSys ’15 (ACM, New York, 2015), pp. 55–64
M. Figueiredo, A. De Almeida, B. Ribeiro, Home electrical signal disaggregation for non-intrusive load monitoring (NILM) systems. Neurocomputing 96, 66–73 (2012)
L.K. Norford, S.B. Leeb, Non-intrusive electrical load monitoring in commercial buildings based on steady-state and transient load-detection algorithms. Energy Build. 24(1), 51–64 (1996)
H.-H. Chang, P.W. Wiratha, N. Chen, A non-intrusive load monitoring system using an embedded system for applications to unbalanced residential distribution systems. Energy Procedia 61, 146–150 (2014)
Y.F. Wong, Y.A. Sekercioglu, T. Drummond, V.S. Wong, Recent approaches to non-intrusive load monitoring techniques in residential settings, in Proceedings of the IEEE Symposium on Computational Intelligence Applications In Smart Grid (CIASG), Singapore, 16–19 Apr. 2013, pp. 73–79
R.S. Butner, D.J. Reid, M. Hoffman, G.P. Sullivan, J. Blanchard, Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol (Pacific Northwest National Laboratory, Richland, 2013)
C. Beckel, W. Kleiminger, R. Cicchetti, T. Staake, S. Santini, The ECO data set and the performance of non-intrusive load monitoring algorithms, in Proceedings of the 1st ACM International Conference on Embedded Systems for Energy-Efficient Buildings (BuildSys 2014), Memphis. November 2014 (ACM, New York, 2014), pp. 80–89
S. Makonin, F. Popowich, L. Bartram, B. Gill, I.V. Bajic, AMPds: a public dataset for load disaggregation and eco-feedback research, in Proceedings of the IEEE Electrical Power and Energy Conference (EPEC), Halifax (2013)
L. Rabiner, A tutorial on hidden Markov models and selected applications in speech recognition. Proc. IEEE 77(2), 257–286 (1989)
Z. Ghahramani, M.I. Jordan, Factorial Hidden Markov models. Mach. Learn. 29(2–3), 245–273 (1997)
S. Pattem, Unsupervised disaggregation for non-intrusive load monitoring, in 2012 11th International Conference on Machine Learning and Applications (ICMLA), vol. 2 (IEEE, Piscataway, 2012), pp. 515–520
O. Parson, S. Ghosh, M. Weal, A. Rogers, Non-intrusive load monitoring using prior models of general appliance types, in Twenty-Sixth Conference on Artificial Intelligence (AAAI-12) (2012)
S. Makonin, F. Popowich, Nonintrusive load monitoring (NILM) performance evaluation. Energy Effic. 8(4), 809–814 (2014)
J.A. Hartigan, M.A. Wong, Algorithm as 136: a k-means clustering algorithm. J. R. Stat. Soc. Ser. C Appl. Stat. 28(1), 100–108 (1979)
D. Egarter, M. Pöchacker, W. Elmenreich, Complexity of power draws for load disaggregation, CoRR (2015)
A.I. Cole, A. Albicki, Algorithm for nonintrusive identification of residential appliances, in Proceedings of the IEEE International Symposium on Circuits and Systems (ISCAS), Monterey, 31 May - 3 Jun. 1998, pp. 338–341
H. Goncalves, A. Ocneanu, M. Berges, Unsupervised disaggregation of appliances using aggregated consumption data, in Proceedings of the 1st KDD Workshop on Data Mining Applications in Sustainability (SustKDD), San Diego (2011)
C. Laughman, K. Lee, R. Cox, S. Shaw, S. Leeb, L. Norford, P. Armstrong, Power signature analysis. IEEE Power Energy Mag. 1(2), 56–63 (2003)
A. Marchiori, D. Hakkarinen, Q. Han, L. Earle, Circuit-level load monitoring for household energy management. IEEE Pervasive Comput. 10(1), 40–48 (2011)
M. Weiss, A. Helfenstein, F. Mattern, T. Staake, Leveraging smart meter data to recognize home appliances, in Proceedings of IEEE International Conference on Pervasive Computing and Communications (PerCom), Lugano (2012), pp. 190–197
L.K. Norford, S.B. Leeb, Non-intrusive electrical load monitoring in commercial buildings based on steady-state and transient load-detection algorithms. Energy Build. 24(1), 51–64 (1996)
M. Berges, E. Goldman, H.S. Matthews, L. Soibelman, K. Anderson, User-centered nonintrusive electricity load monitoring for residential buildings. J. Comput. Civ. Eng. 25(6), 471–480 (2011)
H.-H. Chang, H.-T. Yang, Applying a non-intrusive energy-management system to economic dispatch for a cogeneration system and power utility. Appl. Energy 86(11), 2335–2343 (2009)
H.-H. Chang, Non-intrusive demand monitoring and load identification for energy management systems based on transient feature analyses. Energies 5(11), 4569–4589 (2012)
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2020 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this chapter
Cite this chapter
Bonfigli, R., Squartini, S. (2020). HMM Based Approach. In: Machine Learning Approaches to Non-Intrusive Load Monitoring. SpringerBriefs in Energy. Springer, Cham. https://doi.org/10.1007/978-3-030-30782-0_4
Download citation
DOI: https://doi.org/10.1007/978-3-030-30782-0_4
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-30781-3
Online ISBN: 978-3-030-30782-0
eBook Packages: EnergyEnergy (R0)