Abstract
This work discusses the design of a new method for the continuous differential record of the variable Arterial Blood Pressure (PSA) for noninvasive method (oscillometric) to be employed during the study of the vasovagal syncope in subjects with problems of peripheral circulation during the tilt test. We analyze the different sections of the proposed system, it includes the selection and characterization of the pressure transducer for the differential measurement of the variable; as well as the blocks of the analog channel (multiplexer, amplifier, and filters) and the ARDUINO ONE platform to achieve the control of the acquisition of the data; the control of the filling and emptying of cuffs and besides the communication with a station of processing and control through an interface developed in C #. The obtained results evidence adequate linearity and frequency response, allowing to the study of the variable PSA during the development of Tilt test.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Teodorovich, N., Swissa, M.: Tilt table test today - state of the art. World J. Cardiol. 8(3), 272–282 (2016)
Eza-Nunez, P., et al.: Comparison of three diagnostic tests in detecting vestibular deficit in patients with peripheral vestibulopathy. J. Laryngol. Otol. 130(2), 145–150 (2016)
Naik, C.: Investigating a patient of vertigo: where do we stand today? Indian J. Otol. 23(2), 63–66 (2017)
Nova, P.: Cerebral blood flow, heart rate, and blood pressure patterns during the tilt test in common orthostatic syndromes. Neurosci. J. 1–20 (2016)
Shirley, L., et al.: A review on non-invasive hypertension monitoring system by using photoplethysmography method. Mov. Health Exerc. 6(1), 47–57 (2017)
Cohen, Z., Haxha, S.: Optical based sensor prototype for continuous monitoring of the blood pressure. IEEE Sens. J. 1–12 (2017)
Zheng, D., et al.: Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement. Med. Biol. Eng. Comput. 52, 467–473 (2014)
Zhang, G., et al.: Hybrid optical unobtrusive blood pressure measurements. Sensors 17, 1–12 (2017)
Kiselev, A., et al.: Comprehensive assessment of cardiovascular autonomic control using photoplethysmograms recorded from the earlobe and fingers. Phys. Meas. 37, 580–595 (2016)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Regueiro-Busoch, C., Busoch-Morlán, C., Díaz-Martínez, R.J., Regueiro-Gómez, A. (2020). System to Continuous Differential Acquisition of Arterial Blood Pressure During Tilt Test. In: González Díaz, C., et al. VIII Latin American Conference on Biomedical Engineering and XLII National Conference on Biomedical Engineering. CLAIB 2019. IFMBE Proceedings, vol 75. Springer, Cham. https://doi.org/10.1007/978-3-030-30648-9_80
Download citation
DOI: https://doi.org/10.1007/978-3-030-30648-9_80
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-30647-2
Online ISBN: 978-3-030-30648-9
eBook Packages: EngineeringEngineering (R0)