Skip to main content

System to Continuous Differential Acquisition of Arterial Blood Pressure During Tilt Test

  • Conference paper
  • First Online:
VIII Latin American Conference on Biomedical Engineering and XLII National Conference on Biomedical Engineering (CLAIB 2019)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 75))

Included in the following conference series:

  • 1979 Accesses

Abstract

This work discusses the design of a new method for the continuous differential record of the variable Arterial Blood Pressure (PSA) for noninvasive method (oscillometric) to be employed during the study of the vasovagal syncope in subjects with problems of peripheral circulation during the tilt test. We analyze the different sections of the proposed system, it includes the selection and characterization of the pressure transducer for the differential measurement of the variable; as well as the blocks of the analog channel (multiplexer, amplifier, and filters) and the ARDUINO ONE platform to achieve the control of the acquisition of the data; the control of the filling and emptying of cuffs and besides the communication with a station of processing and control through an interface developed in C #. The obtained results evidence adequate linearity and frequency response, allowing to the study of the variable PSA during the development of Tilt test.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Teodorovich, N., Swissa, M.: Tilt table test today - state of the art. World J. Cardiol. 8(3), 272–282 (2016)

    Article  Google Scholar 

  2. Eza-Nunez, P., et al.: Comparison of three diagnostic tests in detecting vestibular deficit in patients with peripheral vestibulopathy. J. Laryngol. Otol. 130(2), 145–150 (2016)

    Article  Google Scholar 

  3. Naik, C.: Investigating a patient of vertigo: where do we stand today? Indian J. Otol. 23(2), 63–66 (2017)

    Article  MathSciNet  Google Scholar 

  4. Nova, P.: Cerebral blood flow, heart rate, and blood pressure patterns during the tilt test in common orthostatic syndromes. Neurosci. J. 1–20 (2016)

    Google Scholar 

  5. Shirley, L., et al.: A review on non-invasive hypertension monitoring system by using photoplethysmography method. Mov. Health Exerc. 6(1), 47–57 (2017)

    Google Scholar 

  6. Cohen, Z., Haxha, S.: Optical based sensor prototype for continuous monitoring of the blood pressure. IEEE Sens. J. 1–12 (2017)

    Google Scholar 

  7. Zheng, D., et al.: Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement. Med. Biol. Eng. Comput. 52, 467–473 (2014)

    Google Scholar 

  8. Zhang, G., et al.: Hybrid optical unobtrusive blood pressure measurements. Sensors 17, 1–12 (2017)

    Article  Google Scholar 

  9. Kiselev, A., et al.: Comprehensive assessment of cardiovascular autonomic control using photoplethysmograms recorded from the earlobe and fingers. Phys. Meas. 37, 580–595 (2016)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Carmenchu Regueiro-Busoch .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Regueiro-Busoch, C., Busoch-Morlán, C., Díaz-Martínez, R.J., Regueiro-Gómez, A. (2020). System to Continuous Differential Acquisition of Arterial Blood Pressure During Tilt Test. In: González Díaz, C., et al. VIII Latin American Conference on Biomedical Engineering and XLII National Conference on Biomedical Engineering. CLAIB 2019. IFMBE Proceedings, vol 75. Springer, Cham. https://doi.org/10.1007/978-3-030-30648-9_80

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-30648-9_80

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-30647-2

  • Online ISBN: 978-3-030-30648-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics