A Novel Multi-direction Adjustment Strategy for Reducing Ghost Artifact in Body Tomosynthesis

  • Conference paper
  • First Online:
Future Trends in Biomedical and Health Informatics and Cybersecurity in Medical Devices (ICBHI 2019)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 74))

Included in the following conference series:

  • 1010 Accesses

Abstract

Digital tomosynthesis (DT) reduces tissue overlap and provides tomographic images of high quality with clinically acceptable low radiation dose, it begins to be recognized as an essential diagnostic tool. The scanning direction and model are more flexible in DT. However, scanning parameters of DT are not easy to be determined. In this study, we investigated the effect of dual direction scanning on artifact improvement and the optimization of scanning parameters using the INER Prototype Tomosynthesis scanner. The line-pair shape phantom with 2, 3, 5, 8, 10, 15 mm line widths and 5 mm thickness was used. The projections were acquired with 31 views over a 15° angular range in HF (Head-Foot) direction and RL (Right-left) direction, respectively. 3D images were reconstructed with ML-EM algorithm to evaluate the spread range of ghost artifact with various sweep methods (HF, RL and Dual) and object sizes. Moreover, the projection number ratios (PNR) in dual directions were also evaluated for the influence on artifacts. Under single direction sweep (HF or RL), the spread range was wide when the sweep direction paralleled with the shape direction of object (SDO); the spread range was narrow when the sweep direction is perpendicular to the SDO. The spread range of dual scan was unaffected by the SDO. The PNR in dual directions revealed a similar trend to single direction sweep when the ratio is not equal to one. Based on the above experimental results, we proposed a novel multi-direction adjustment strategy for body tomosynthesis. For the default scanning, the user should choose the isotropic dual direction scan (PNR = 1). After preview, the advanced process can use different PNR depending on the anatomy of interest to improve diagnostic image quality to reduce ghost artifact and distortion.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Dobbins III, J.T., Godfrey, D.J.: Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys. Med. Biol. 48(19), R65–R106 (2003)

    Article  Google Scholar 

  2. Vikgren, J., Zachrisson, S., Svalkvist, A., et al.: Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249(3), 1034–1041 (2008)

    Article  Google Scholar 

  3. Gennaro, G., Toledano, A., DiMaggio, C., et al.: Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur. Radiol. 20(7), 1545–1553 (2010)

    Article  Google Scholar 

  4. Ueno, E., Moribe, Y., Sabol, J.M.: Optimizing parameters for flat-panel detector. Radiographics 30(2), 549–562 (2010)

    Article  Google Scholar 

  5. Zhong, Y., Lai, C.J., Wang, T., et al.: A dual-view digital tomosynthesis imaging technique for improved chest imaging. Med. Phys. 42(9), 5238–5251 (2015)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yu-Ching Ni .

Editor information

Editors and Affiliations

Ethics declarations

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Ni, YC., Lin, CY., Chang, CH., Tseng, FP., Tseng, SP., Chuang, KS. (2020). A Novel Multi-direction Adjustment Strategy for Reducing Ghost Artifact in Body Tomosynthesis. In: Lin, KP., Magjarevic, R., de Carvalho, P. (eds) Future Trends in Biomedical and Health Informatics and Cybersecurity in Medical Devices. ICBHI 2019. IFMBE Proceedings, vol 74. Springer, Cham. https://doi.org/10.1007/978-3-030-30636-6_15

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-30636-6_15

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-30635-9

  • Online ISBN: 978-3-030-30636-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics