Skip to main content

Abstract

This chapter covers the fundamental aspects of post-procedural follow-up imaging, after surgical aortic valve replacement and after TAVI procedure.

The central role in this context is played by echocardiography, angiography, and the use of cardiac computed tomography and in selected cases of cardiac magnetic resonance imaging.

The correct diagnosis and classification of postoperative complications, from prosthesis malfunctions (patient-prosthesis mismatch, endocarditis, thrombosis and leaflets motion abnormalities) to post-implantation paravalvular leaks, to problems related to vascular access (bleeding, dissections and compartment syndrome) are described in detail and discussed, along with the treatments.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kataruka A, Otto CM. Valve durability after transcatheter aortic valve implantation. J Thorac Dis. 2018;10(Suppl 30):S3629–s3636.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Butany J, Collins MJ. Analysis of prosthetic cardiac devices: a guide for the practising pathologist. J Clin Pathol. 2005;58(2):113–24.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Wang M, Furnary AP, Li HF, Grunkemeier GL. Bioprosthetic aortic valve durability: a meta-regression of published studies. Ann Thorac Surg. 2017;104(3):1080–7.

    Article  PubMed  Google Scholar 

  4. Dasi LP, Hatoum H, Kheradvar A, Zareian R, Alavi SH, Sun W, Martin C, Pham T, Wang Q, Midha PA, Raghav V, Yoganathan AP. On the mechanics of transcatheter aortic valve replacement. Ann Biomed Eng. 2017;45(2):310–31.

    Article  PubMed  Google Scholar 

  5. Foroutan F, Guyatt GH, O’Brien K, Bain E, Stein M, Bhagra S, Sit D, Kamran R, Chang Y, Devji T, Mir H, Manja V, Schofield T, Siemieniuk RA, Agoritsas T, Bagur R, Otto CM, Vandvik PO. Prognosis after surgical replacement with a bioprosthetic aortic valve in patients with severe symptomatic aortic stenosis: systematic review of observational studies. BMJ. 2016;354:i5065.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Martin C, Sun W. Transcatheter valve underexpansion limits leaflet durability: implications for valve-in-valve procedures. Ann Biomed Eng. 2017;45(2):394–404.

    Article  PubMed  Google Scholar 

  7. Martin C, Sun W. Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: a fatigue simulation study. J Biomech. 2015;48(12):3026–34.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Pislaru SV, Nkomo VT, Sandhu GS. Assessment of prosthetic valve function after TAVR. JACC Cardiovasc Imaging. 2016;9(2):193–206.

    Article  PubMed  Google Scholar 

  9. Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, Iung B, Lancellotti P, Lansac E, Rodriguez Munoz D, Rosenhek R, Sjogren J, Tornos Mas P, Vahanian A, Walther T, Wendler O, Windecker S, Zamorano JL. 2017 ESC/EACTS Guidelines for the management of valvular heart disease. Eur Heart J. 2017;38(36):2739–91.

    Article  PubMed  Google Scholar 

  10. Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP 3rd, Fleisher LA, Jneid H, Mack MJ, McLeod CJ, O’Gara PT, Rigolin VH, Sundt TM 3rd, Thompson A. 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2017;135(25):e1159–95.

    Article  PubMed  Google Scholar 

  11. Lancellotti P, Pibarot P, Chambers J, Edvardsen T, Delgado V, Dulgheru R, Pepi M, Cosyns B, Dweck MR, Garbi M, Magne J, Nieman K, Rosenhek R, Bernard A, Lowenstein J, Vieira ML, Rabischoffsky A, Vyhmeister RH, Zhou X, Zhang Y, Zamorano JL, Habib G. Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2016;17(6):589–90.

    Article  PubMed  Google Scholar 

  12. Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA, Khandheria BK, Levine RA, Marx GR, Miller FA Jr, Nakatani S, Quinones MA, Rakowski H, Rodriguez LL, Swaminathan M, Waggoner AD, Weissman NJ, Zabalgoitia M. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography’s Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2009;22(9):975–1014; quiz 1082–4.

    Article  PubMed  Google Scholar 

  13. Bloomfield GS, Gillam LD, Hahn RT, Kapadia S, Leipsic J, Lerakis S, Tuzcu M, Douglas PS. A practical guide to multimodality imaging of transcatheter aortic valve replacement. JACC Cardiovasc Imaging. 2012;5(4):441–55.

    Article  PubMed  Google Scholar 

  14. Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, Calhoon JH, Carabello BA, Desai MY, Edwards FH, Francis GS, Gardner TJ, Kappetein AP, Linderbaum JA, Mukherjee C, Mukherjee D, Otto CM, Ruiz CE, Sacco RL, Smith D, Thomas JD, Harrington RA, Bhatt DL, Ferrari VA, Fisher JD, Garcia MJ, Gardner TJ, Gentile F, Gilson MF, Hernandez AF, Jacobs AK, Kaul S, Linderbaum JA, Moliterno DJ, Weitz HH. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement: developed in collabration with the American Heart Association, American Society of Echocardiography, European Association for Cardio-Thoracic Surgery, Heart Failure Society of America, Mended Hearts, Society of Cardiovascular Anesthesiologists, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance. J Thorac Cardiovasc Surg. 2012;144(3):e29–84.

    Article  PubMed  Google Scholar 

  15. Thourani VH, Kodali S, Makkar RR, Herrmann HC, Williams M, Babaliaros V, Smalling R, Lim S, Malaisrie SC, Kapadia S, Szeto WY, Greason KL, Kereiakes D, Ailawadi G, Whisenant BK, Devireddy C, Leipsic J, Hahn RT, Pibarot P, Weissman NJ, Jaber WA, Cohen DJ, Suri R, Tuzcu EM, Svensson LG, Webb JG, Moses JW, Mack MJ, Miller DC, Smith CR, Alu MC, Parvataneni R, D’Agostino RB Jr, Leon MB. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet. 2016;387(10034):2218–25.

    Article  PubMed  Google Scholar 

  16. Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, Doshi D, Cohen DJ, Pichard AD, Kapadia S, Dewey T, Babaliaros V, Szeto WY, Williams MR, Kereiakes D, Zajarias A, Greason KL, Whisenant BK, Hodson RW, Moses JW, Trento A, Brown DL, Fearon WF, Pibarot P, Hahn RT, Jaber WA, Anderson WN, Alu MC, Webb JG. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2016;374(17):1609–20.

    Article  CAS  PubMed  Google Scholar 

  17. Hammermeister KE, Sethi GK, Henderson WG, Oprian C, Kim T, Rahimtoola S. A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis. Veterans Affairs Cooperative Study on Valvular Heart Disease. N Engl J Med. 1993;328(18):1289–96.

    Article  CAS  PubMed  Google Scholar 

  18. Hammermeister K, Sethi GK, Henderson WG, Grover FL, Oprian C, Rahimtoola SH. Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial. J Am Coll Cardiol. 2000;36(4):1152–8.

    Article  CAS  PubMed  Google Scholar 

  19. Durrleman N, Pellerin M, Bouchard D, Hebert Y, Cartier R, Perrault LP, Basmadjian A, Carrier M. Prosthetic valve thrombosis: twenty-year experience at the Montreal Heart Institute. J Thorac Cardiovasc Surg. 2004;127(5):1388–92.

    Article  PubMed  Google Scholar 

  20. Roudaut R, Serri K, Lafitte S. Thrombosis of prosthetic heart valves: diagnosis and therapeutic considerations. Heart. 2007;93(1):137–42.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Barbetseas J, Nagueh SF, Pitsavos C, Toutouzas PK, Quinones MA, Zoghbi WA. Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters. J Am Coll Cardiol. 1998;32(5):1410–7.

    Article  CAS  PubMed  Google Scholar 

  22. Tanis W, Habets J, van den Brink RB, Symersky P, Budde RP, Chamuleau SA. Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature. Eur Heart J Cardiovasc Imaging. 2014;15(2):119–29.

    Article  PubMed  Google Scholar 

  23. Lin SS, Tiong IY, Asher CR, Murphy MT, Thomas JD, Griffin BP. Prediction of thrombus-related mechanical prosthetic valve dysfunction using transesophageal echocardiography. Am J Cardiol. 2000;86(10):1097–101.

    Article  CAS  PubMed  Google Scholar 

  24. Gunduz S, Ozkan M, Kalcik M, Gursoy OM, Astarcioglu MA, Karakoyun S, Aykan AC, Biteker M, Gokdeniz T, Kaya H, Yesin M, Duran NE, Sevinc D, Guneysu T. Sixty-four-section cardiac computed tomography in mechanical prosthetic heart valve dysfunction: thrombus or pannus. Circ Cardiovasc Imaging. 2015;8(12):e003246.

    Article  PubMed  Google Scholar 

  25. Ueda T, Teshima H, Fukunaga S, Aoyagi S, Tanaka H. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography—identification of subprosthetic pannus in the aortic position. Circ J. 2013;77(2):418–23.

    Article  PubMed  Google Scholar 

  26. Sucha D, Symersky P, Tanis W, Mali WP, Leiner T, van Herwerden LA, Budde RP. Multimodality imaging assessment of prosthetic heart valves. Circ Cardiovasc Imaging. 2015;8(9):e003703.

    Article  PubMed  Google Scholar 

  27. Mylotte D, Andalib A, Theriault-Lauzier P, Dorfmeister M, Girgis M, Alharbi W, Chetrit M, Galatas C, Mamane S, Sebag I, Buithieu J, Bilodeau L, de Varennes B, Lachapelle K, Lange R, Martucci G, Virmani R, Piazza N. Transcatheter heart valve failure: a systematic review. Eur Heart J. 2015;36(21):1306–27.

    Article  PubMed  Google Scholar 

  28. Ong SH, Mueller R, Iversen S. Early calcific degeneration of a CoreValve transcatheter aortic bioprosthesis. Eur Heart J. 2012;33(5):586.

    Article  PubMed  Google Scholar 

  29. Thubrikar MJ, Deck JD, Aouad J, Nolan SP. Role of mechanical stress in calcification of aortic bioprosthetic valves. J Thorac Cardiovasc Surg. 1983;86(1):115–25.

    Article  CAS  PubMed  Google Scholar 

  30. Richardt D, Hanke T, Sievers HH. Two cases of heart failure after implantation of a CoreValve prosthesis. N Engl J Med. 2015;372(11):1079–80.

    Article  CAS  PubMed  Google Scholar 

  31. Arsalan M, Walther T. Durability of prostheses for transcatheter aortic valve implantation. Nat Rev Cardiol. 2016;13(6):360–7.

    Article  CAS  PubMed  Google Scholar 

  32. Hahn RT, Kodali S, Tuzcu EM, Leon MB, Kapadia S, Gopal D, Lerakis S, Lindman BR, Wang Z, Webb J, Thourani VH, Douglas PS. Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement. JACC Cardiovasc Imaging. 2015;8(3):288–318.

    Article  PubMed  PubMed Central  Google Scholar 

  33. Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, Calhoon JH, Carabello BA, Desai MY, Edwards FH, Francis GS, Gardner TJ, Kappetein AP, Linderbaum JA, Mukherjee C, Mukherjee D, Otto CM, Ruiz CE, Sacco RL, Smith D, Thomas JD. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol. 2012;59(13):1200–54.

    Article  PubMed  Google Scholar 

  34. Alavi SH, Groves EM, Kheradvar A. The effects of transcatheter valve crimping on pericardial leaflets. Ann Thorac Surg. 2014;97(4):1260–6.

    Article  PubMed  Google Scholar 

  35. Sun W, Li K, Sirois E. Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment. J Biomech. 2010;43(16):3085–90.

    Article  PubMed  Google Scholar 

  36. Martin C, Sun W. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties. Biomech Model Mechanobiol. 2014;13(4):759–70.

    Article  PubMed  Google Scholar 

  37. Vesely I. The influence of design on bioprosthetic valve durability. J Long-Term Eff Med Implants. 2001;11(3–4):137–49.

    CAS  PubMed  Google Scholar 

  38. Salaun E, Zenses AS, Evin M, Collart F, Habib G, Pibarot P, Rieu R. Effect of oversizing and elliptical shape of aortic annulus on transcatheter valve hemodynamics: an in vitro study. Int J Cardiol. 2016;208:28–35.

    Article  PubMed  Google Scholar 

  39. Chakravarty T, Sondergaard L, Friedman J, De Backer O, Berman D, Kofoed KF, Jilaihawi H, Shiota T, Abramowitz Y, Jorgensen TH, Rami T, Israr S, Fontana G, de Knegt M, Fuchs A, Lyden P, Trento A, Bhatt DL, Leon MB, Makkar RR. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study. Lancet. 2017;389(10087):2383–92.

    Article  PubMed  Google Scholar 

  40. Doris MK, Dweck MR. Is bioprosthetic leaflet thrombosis a trigger to valve degeneration? Heart. 2018;104(10):792–3.

    Article  PubMed  CAS  Google Scholar 

  41. Flameng W, Herregods MC, Vercalsteren M, Herijgers P, Bogaerts K, Meuris B. Prosthesis-patient mismatch predicts structural valve degeneration in bioprosthetic heart valves. Circulation. 2010;121(19):2123–9.

    Article  PubMed  Google Scholar 

  42. Genereux P, Head SJ, Hahn R, Daneault B, Kodali S, Williams MR, van Mieghem NM, Alu MC, Serruys PW, Kappetein AP, Leon MB. Paravalvular leak after transcatheter aortic valve replacement: the new Achilles’ heel? A comprehensive review of the literature. J Am Coll Cardiol. 2013;61(11):1125–36.

    Article  PubMed  Google Scholar 

  43. Bruschi G, Botta L, Fratto P, Martinelli L. Failed valve-in-valve transcatheter mitral valve implantation. Eur J Cardiothorac Surg. 2014;45(4):e127.

    Article  PubMed  Google Scholar 

  44. Harbaoui B, Courand PY, Schmitt Z, Farhat F, Dauphin R, Lantelme P. Early Edwards SAPIEN valve degeneration after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2016;9(2):198–9.

    Article  PubMed  Google Scholar 

  45. Kiefer P, Seeburger J, Chu MW, Ender J, Vollroth M, Noack T, Mohr FW, Holzhey DM. Reoperative transapical aortic valve implantation for early structural valve deterioration of a SAPIEN XT valve. Ann Thorac Surg. 2013;95(6):2169–70.

    Article  PubMed  Google Scholar 

  46. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodes-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Am Coll Cardiol. 2012;60(15):1438–54.

    Article  PubMed  Google Scholar 

  47. Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T, Kodali SK, Mack MJ, Thourani VH, Miller DC, Svensson LG, Herrmann HC, Smith CR, Rodes-Cabau J, Webb J, Lim S, Xu K, Hueter I, Douglas PS, Leon MB. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort—a analysis. J Am Coll Cardiol. 2014;64(13):1323–34.

    Article  PubMed  PubMed Central  Google Scholar 

  48. Ewe SH, Muratori M, Delgado V, Pepi M, Tamborini G, Fusini L, Klautz RJ, Gripari P, Bax JJ, Fusari M, Schalij MJ, Marsan NA. Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation. J Am Coll Cardiol. 2011;58(18):1910–8.

    Article  PubMed  Google Scholar 

  49. Jilaihawi H, Chin D, Spyt T, Jeilan M, Vasa-Nicotera M, Bence J, Logtens E, Kovac J. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis. Eur Heart J. 2010;31(7):857–64.

    Article  PubMed  Google Scholar 

  50. Clavel MA, Webb JG, Pibarot P, Altwegg L, Dumont E, Thompson C, De Larochelliere R, Doyle D, Masson JB, Bergeron S, Bertrand OF, Rodes-Cabau J. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. J Am Coll Cardiol. 2009;53(20):1883–91.

    Article  PubMed  Google Scholar 

  51. Kim SJ, Samad Z, Bloomfield GS, Douglas PS. A critical review of hemodynamic changes and left ventricular remodeling after surgical aortic valve replacement and percutaneous aortic valve replacement. Am Heart J. 2014;168(2):150–9.e1–7.

    Article  PubMed  Google Scholar 

  52. Herrmann HC, Daneshvar SA, Fonarow GC, Stebbins A, Vemulapalli S, Desai ND, Malenka DJ, Thourani VH, Rymer J, Kosinski AS. Prosthesis-patient mismatch in patients undergoing transcatheter aortic valve replacement: from the STS/ACC TVT registry. J Am Coll Cardiol. 2018;72(22):2701–11.

    Article  PubMed  Google Scholar 

  53. Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, Dulgheru R, El Khoury G, Erba PA, Iung B, Miro JM, Mulder BJ, Plonska-Gosciniak E, Price S, Roos-Hesselink J, Snygg-Martin U, Thuny F, Tornos Mas P, Vilacosta I, Zamorano JL. ESC Guidelines for the management of infective endocarditis: the Task Force for the Management of Infective Endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J. 2015;36(44):3075–128.

    Article  PubMed  Google Scholar 

  54. Latib A, Naim C, De Bonis M, Sinning JM, Maisano F, Barbanti M, Parolari A, Lorusso R, Testa L, Actis Dato GM, Miceli A, Sponga S, Rosato F, De Vincentiis C, Werner N, Fiorina C, Bartorelli A, Di Gregorio O, Casilli F, Muratori M, Alamanni F, Glauber M, Livi U, Nickenig G, Tamburino C, Alfieri O, Colombo A. TAVR-associated prosthetic valve infective endocarditis: results of a large, multicenter registry. J Am Coll Cardiol. 2014;64(20):2176–8.

    Article  PubMed  Google Scholar 

  55. Sulzenko J, Tousek P, Linkova H. Infective endocarditis as a mid-term complication after transcatheter aortic valve implantation: case report and literature review. Catheter Cardiovasc Interv. 2014;84(2):311–5.

    Article  PubMed  Google Scholar 

  56. Amat-Santos IJ, Messika-Zeitoun D, Eltchaninoff H, Kapadia S, Lerakis S, Cheema AN, Gutierrez-Ibanes E, Munoz-Garcia AJ, Pan M, Webb JG, Herrmann HC, Kodali S, Nombela-Franco L, Tamburino C, Jilaihawi H, Masson JB, de Brito FS Jr, Ferreira MC, Lima VC, Mangione JA, Iung B, Vahanian A, Durand E, Tuzcu EM, Hayek SS, Angulo-Llanos R, Gomez-Doblas JJ, Castillo JC, Dvir D, Leon MB, Garcia E, Cobiella J, Vilacosta I, Barbanti M, Makkar R R, Ribeiro HB, Urena M, Dumont E, Pibarot P, Lopez J, San Roman A, Rodes-Cabau J. Infective endocarditis after transcatheter aortic valve implantation: results from a large multicenter registry. Circulation. 2015;131(18):1566–74.

    Article  PubMed  Google Scholar 

  57. Latib A, Naganuma T, Abdel-Wahab M, Danenberg H, Cota L, Barbanti M, Baumgartner H, Finkelstein A, Legrand V, de Lezo JS, Kefer J, Messika-Zeitoun D, Richardt G, Stabile E, Kaleschke G, Vahanian A, Laborde JC, Leon MB, Webb JG, Panoulas VF, Maisano F, Alfieri O, Colombo A. Treatment and clinical outcomes of transcatheter heart valve thrombosis. Circ Cardiovasc Interv. 2015;8(4):e001779.

    Article  PubMed  Google Scholar 

  58. Mylotte D, Piazza N. Transcatheter aortic valve replacement failure: deja vu ou jamais vu? Circ Cardiovasc Interv. 2015;8(4):e002531.

    Article  PubMed  Google Scholar 

  59. Sinning JM, Vasa-Nicotera M, Chin D, Hammerstingl C, Ghanem A, Bence J, Kovac J, Grube E, Nickenig G, Werner N. Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol. 2013;62(1):11–20.

    Article  PubMed  Google Scholar 

  60. Trepels T, Martens S, Doss M, Fichtlscherer S, Schachinger V. Images in cardiovascular medicine. Thrombotic restenosis after minimally invasive implantation of aortic valve stent. Circulation. 2009;120(4):e23–4.

    Article  PubMed  Google Scholar 

  61. De Marchena E, Mesa J, Pomenti S, Marin YKC, Marincic X, Yahagi K, Ladich E, Kutz R, Aga Y, Ragosta M, Chawla A, Ring ME, Virmani R. Thrombus formation following transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2015;8(5):728–39.

    Article  PubMed  Google Scholar 

  62. Makkar RR, Fontana G, Jilaihawi H, Chakravarty T, Kofoed KF, De Backer O, Asch FM, Ruiz CE, Olsen NT, Trento A, Friedman J, Berman D, Cheng W, Kashif M, Jelnin V, Kliger CA, Guo H, Pichard AD, Weissman NJ, Kapadia S, Manasse E, Bhatt DL, Leon MB, Sondergaard L. Possible subclinical leaflet thrombosis in bioprosthetic aortic valves. N Engl J Med. 2015;373(21):2015–24.

    Article  CAS  PubMed  Google Scholar 

  63. Egbe AC, Pislaru SV, Pellikka PA, Poterucha JT, Schaff HV, Maleszewski JJ, Connolly HM. Bioprosthetic valve thrombosis versus structural failure: clinical and echocardiographic predictors. J Am Coll Cardiol. 2015;66(21):2285–94.

    Article  PubMed  Google Scholar 

  64. Pislaru SV, Pellikka PA, Schaff HV, Connolly HM. Bioprosthetic valve thrombosis: the eyes will not see what the mind does not know. J Thorac Cardiovasc Surg. 2015;149(6):e86–7.

    Article  PubMed  Google Scholar 

  65. Pislaru SV, Hussain I, Pellikka PA, Maleszewski JJ, Hanna RD, Schaff HV, Connolly HM. Misconceptions, diagnostic challenges and treatment opportunities in bioprosthetic valve thrombosis: lessons from a case series. Eur J Cardiothorac Surg. 2015;47(4):725–32.

    Article  PubMed  Google Scholar 

  66. Sondergaard L, Sigitas C, Chopra M, Bieliauskas G, De Backer O. Leaflet thrombosis after TAVI. Eur Heart J. 2017;38(36):2702–3.

    Article  PubMed  CAS  Google Scholar 

  67. Sondergaard L, De Backer O, Kofoed KF, Jilaihawi H, Fuchs A, Chakravarty T, Kashif M, Kazuno Y, Kawamori H, Maeno Y, Bieliauskas G, Guo H, Stone GW, Makkar R. Natural history of subclinical leaflet thrombosis affecting motion in bioprosthetic aortic valves. Eur Heart J. 2017;38(28):2201–7.

    Article  CAS  PubMed  Google Scholar 

  68. Khatri PJ, Webb JG, Rodes-Cabau J, Fremes SE, Ruel M, Lau K, Guo H, Wijeysundera HC, Ko DT. Adverse effects associated with transcatheter aortic valve implantation: a meta-analysis of contemporary studies. Ann Intern Med. 2013;158(1):35–46.

    Article  PubMed  Google Scholar 

  69. Pang PY, Chiam PT, Chua YL, Sin YK. A survivor of late prosthesis migration and rotation following percutaneous transcatheter aortic valve implantation. Eur J Cardiothorac Surg. 2012;41(5):1195–6.

    Article  PubMed  Google Scholar 

  70. Masson JB, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S, Tuzcu ME, Kodali S, Leon MB, Webb JG. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv. 2009;2(9):811–20.

    Article  PubMed  Google Scholar 

  71. Latib A, Michev I, Laborde JC, Montorfano M, Colombo A. Post-implantation repositioning of the CoreValve percutaneous aortic valve. JACC Cardiovasc Interv. 2010;3(1):119–21.

    Article  PubMed  Google Scholar 

  72. Schultz CJ, Weustink A, Piazza N, Otten A, Mollet N, Krestin G, van Geuns RJ, de Feyter P, Serruys PW, de Jaegere P. Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis. J Am Coll Cardiol. 2009;54(10):911–8.

    Article  PubMed  Google Scholar 

  73. Schultz CJ, Tzikas A, Moelker A, Rossi A, Nuis RJ, Geleijnse MM, van Mieghem N, Krestin GP, de Feyter P, Serruys PW, de Jaegere PP. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis. Catheter Cardiovasc Interv. 2011;78(3):446–55.

    PubMed  Google Scholar 

  74. Eggebrecht H, Doss M, Schmermund A, Nowak B, Krissel J, Voigtlander T. Interventional options for severe aortic regurgitation after transcatheter aortic valve implantation: balloons, snares, valve-in-valve. Clin Res Cardiol. 2012;101(6):503–7.

    Article  PubMed  Google Scholar 

  75. Lerakis S, Hayek SS, Douglas PS. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation. 2013;127(3):397–407.

    Article  PubMed  Google Scholar 

  76. Nkomo VT, Suri RM, Pislaru SV, Greason KL, Sinak LJ, Holmes DR, Mathew V, Rihal CS. Delayed transcatheter heart valve migration and failure. JACC Cardiovasc Imaging. 2014;7(9):960–2.

    Article  PubMed  Google Scholar 

  77. Jose J, Sulimov DS, El-Mawardy M, Sato T, Allali A, Holy EW, Becker B, Landt M, Kebernik J, Schwarz B, Richardt G, Abdel-Wahab M. Clinical bioprosthetic heart valve thrombosis after transcatheter aortic valve replacement: incidence, characteristics, and treatment outcomes. JACC Cardiovasc Interv. 2017;10(7):686–97.

    Article  PubMed  Google Scholar 

  78. Pache G, Schoechlin S, Blanke P, Dorfs S, Jander N, Arepalli CD, Gick M, Buettner HJ, Leipsic J, Langer M, Neumann FJ, Ruile P. Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves. Eur Heart J. 2016;37(28):2263–71.

    Article  PubMed  Google Scholar 

  79. Leetmaa T, Hansson NC, Leipsic J, Jensen K, Poulsen SH, Andersen HR, Jensen JM, Webb J, Blanke P, Tang M, Norgaard BL. Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography. Circ Cardiovasc Interv. 2015;8(4):e001596.

    Article  PubMed  Google Scholar 

  80. Sondergaard L. Subclinical leaflet thrombosis in bioprosthetic aortic valves. JACC Cardiovasc Interv. 2017;10(2):204–5.

    Article  PubMed  Google Scholar 

  81. Testa L, Latib A. Assessing the risk of leaflet motion abnormality following transcatheter aortic valve implantation. Interv Cardiol. 2018;13(1):37–9.

    PubMed  PubMed Central  Google Scholar 

  82. Bax JJ, Stone GW. Bioprosthetic surgical and transcatheter heart valve thrombosis. Lancet. 2017;389(10087):2352–4.

    Article  PubMed  Google Scholar 

  83. Laschinger JC, Wu C, Ibrahim NG, Shuren JE. Reduced leaflet motion in bioprosthetic aortic valves—the FDA perspective. N Engl J Med. 2015;373(21):1996–8.

    Article  CAS  PubMed  Google Scholar 

  84. Pibarot P, Hahn RT, Weissman NJ, Monaghan MJ. Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme. JACC Cardiovasc Imaging. 2015;8(3):340–60.

    Article  PubMed  Google Scholar 

  85. Ribeiro HB, Orwat S, Hayek SS, Larose E, Babaliaros V, Dahou A, Le Ven F, Pasian S, Puri R, Abdul-Jawad Altisent O, Campelo-Parada F, Clavel MA, Pibarot P, Lerakis S, Baumgartner H, Rodes-Cabau J. Cardiovascular magnetic resonance to evaluate aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol. 2016;68(6):577–85.

    Article  PubMed  Google Scholar 

  86. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17):1597–607.

    Article  CAS  PubMed  Google Scholar 

  87. Klein AA, Skubas NJ, Ender JJA. Controversies and complications in the perioperative management of transcatheter aortic valve replacement. Anesth Analg. 2014;119(4):784–98.

    Article  PubMed  Google Scholar 

  88. Hamm CW, Möllmann H, Holzhey D, Beckmann A, Veit C, Figulla H-R, Cremer J, Kuck K-H, Lange R, Zahn R. The German aortic valve registry (GARY): in-hospital outcome. Eur Heart J. 2013;35(24):1588–98.

    Article  PubMed  PubMed Central  Google Scholar 

  89. Généreux P, Head SJ, Van Mieghem NM, Kodali S, Kirtane AJ, Xu K, Smith C, Serruys PW, Kappetein AP, Leon MB. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol. 2012;59(25):2317–26.

    Article  PubMed  Google Scholar 

  90. Kempfert J, Rastan A, Holzhey D, Linke A, Schuler G, van Linden A, Blumenstein J, Mohr FW, Walther TJC. Transapical aortic valve implantation: analysis of risk factors and learning experience in 299 patients. 2011;124(11 Suppl):S124–9.

    Google Scholar 

  91. Sharma A, Arbab-Zadeh A, Dubey D, Shani J, Lazar J, Frankel R. Access site bleeding after transcatheter aortic valve implantation. J Thromb Thrombolysis. 2013;35(4):463–8.

    Article  PubMed  Google Scholar 

  92. Mollmann H, Kim WK, Kempfert J, Walther T, Hamm C. Complications of transcatheter aortic valve implantation (TAVI): how to avoid and treat them. Heart. 2015;101(11):900–8.

    Article  PubMed  Google Scholar 

  93. Tonnessen BH. Iatrogenic injury from vascular access and endovascular procedures. Perspect Vasc Surg Endovasc Ther. 2011;23(2):128–35.

    Article  PubMed  Google Scholar 

  94. Chaudhry MA, Sardar MR. Vascular complications of transcatheter aortic valve replacement: a concise literature review. World J Cardiol. 2017;9(7):574.

    Article  PubMed  PubMed Central  Google Scholar 

  95. Stone PA, AbuRahma AF, Flaherty SK, Bates MC. Femoral pseudoaneurysms. Vasc Endovascular Surg. 2006;40(2):109–17.

    Article  PubMed  Google Scholar 

  96. Toggweiler S, Gurvitch R, Leipsic J, Wood DA, Willson AB, Binder RK, Cheung A, Ye J, Webb JG. Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol. 2012;59(2):113–8.

    Article  PubMed  Google Scholar 

  97. Sharp AS, Michev I, Maisano F, Taramasso M, Godino C, Latib A, Denti P, Dorigo E, Giacomini A, Iaci G. A new technique for vascular access management in transcatheter aortic valve implantation. Catheter Cardiovasc Interv. 2010;75(5):784–93.

    Article  PubMed  Google Scholar 

  98. Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, Mylotte D, Uribe J, Farge A, Donzeau-Gouge P. Transfemoral aortic valve implantation: new criteria to predict vascular complications. JACC Cardiovasc Interv. 2011;4(8):851–8.

    Article  PubMed  Google Scholar 

  99. Kelm M, Perings SM, Jax T, Lauer T, Schoebel FC, Heintzen MP, Perings C, Strauer BE. Incidence and clinical outcome of iatrogenic femoral arteriovenous fistulas: implications for risk stratification and treatment. J Am Coll Cardiol. 2002;40(2):291–7.

    Article  PubMed  Google Scholar 

  100. Toggweiler S, Leipsic J, Binder RK, Freeman M, Barbanti M, Heijmen RH, Wood DA, Webb JG. Management of vascular access in transcatheter aortic valve replacement: part 2: vascular complications. JACC Cardiovasc Interv. 2013;6(8):767–76.

    Article  PubMed  Google Scholar 

  101. Stortecky S, Wenaweser P, Diehm N, Pilgrim T, Huber C, Rosskopf AB, Khattab AA, Buellesfeld L, Gloekler S, Eberle B, Schmidli J, Carrel T, Meier B, Windecker S. Percutaneous management of vascular complications in patients undergoing transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2012;5(5):515–24.

    Article  PubMed  Google Scholar 

  102. Genereux P, Webb JG, Svensson LG, Kodali SK, Satler LF, Fearon WF, Davidson CJ, Eisenhauer AC, Makkar RR, Bergman GW, Babaliaros V, Bavaria JE, Velazquez OC, Williams MR, Hueter I, Xu K, Leon MB. Vascular complications after transcatheter aortic valve replacement: insights from the PARTNER (Placement of AoRTic TraNscathetER Valve) trial. J Am Coll Cardiol. 2012;60(12):1043–52.

    Article  PubMed  Google Scholar 

  103. Unzue L, Garcia E, Teijeiro R, Rubio-Alonso B. Percutaneous closure of a femoral arteriovenous fistula during transfemoral TAVI. J Invasive Cardiol. 2018;30(8):E67–e68.

    PubMed  Google Scholar 

  104. Barbanti M, Binder RK, Freeman M, Wood DA, Leipsic J, Cheung A, Ye J, Tan J, Toggweiler S, Yang TH, Dvir D, Maryniak K, Lauck S, Webb JG. Impact of low-profile sheaths on vascular complications during transfemoral transcatheter aortic valve replacement. EuroIntervention. 2013;9(8):929–35.

    Article  PubMed  Google Scholar 

  105. Creager MA, Kaufman JA, Conte MS. Clinical practice. Acute limb ischemia. N Engl J Med. 2012;366(23):2198–206.

    Article  CAS  PubMed  Google Scholar 

  106. Schmidt AH. Acute compartment syndrome. Injury. 2017;48(Suppl 1):S22–s25.

    Article  PubMed  Google Scholar 

  107. McNally MM, Univers J. Acute limb ischemia. Surg Clin North Am. 2018;98(5):1081–96.

    Article  PubMed  Google Scholar 

  108. Conte JV, Hermiller J Jr, Resar JR, Deeb GM, Gleason TG, Adams DH, Popma JJ, Yakubov SJ, Watson D, Guo J, Zorn GL 3rd, Reardon MJ. Complications after self-expanding transcatheter or surgical aortic valve replacement. Semin Thorac Cardiovasc Surg. 2017;29(3):321–30.

    Article  PubMed  Google Scholar 

  109. Ong SH, Mueller R, Gerckens U. Iatrogenic dissection of the ascending aorta during TAVI sealed with the CoreValve revalving prosthesis. Catheter Cardiovasc Interv. 2011;77(6):910–4.

    Article  PubMed  Google Scholar 

  110. Berfield KK, Sweet MP, McCabe JM, Reisman M, Mackensen GB, Mokadam NA, Dean LS, Smith JW. Endovascular repair for type A aortic dissection after transcatheter aortic valve replacement with a Medtronic CoreValve. Ann Thorac Surg. 2015;100(4):1444–6.

    Article  PubMed  Google Scholar 

  111. Jacobzon E, Wolak A, Fink D, Silberman S. Delayed aortic dissection and valve thrombosis after transcatheter aortic valve implantation. Catheter Cardiovasc Interv. 2019;93(7):E391–3.

    Article  PubMed  Google Scholar 

  112. Nagasawa A, Shirai S, Hanyu M, Arai Y, Kamioka N, Hayashi M. Descending aortic dissection injured by tip of the sheath during transcatheter aortic valve implantation. Cardiovasc Interv Ther. 2016;31(2):122–7.

    Article  PubMed  Google Scholar 

  113. Lempel JK, Frazier AA, Jeudy J, Kligerman SJ, Schultz R, Ninalowo HA, Gozansky EK, Griffith B, White CS. Aortic arch dissection: a controversy of classification. Radiology. 2014;271(3):848–55.

    Article  PubMed  Google Scholar 

  114. Hayek SS, Corrigan FE 3rd, Condado JF, Lin S, Howell S, MacNamara JP, Zheng S, Keegan P, Thourani V, Babaliaros VC, Lerakis S. Paravalvular regurgitation after transcatheter aortic valve replacement: comparing transthoracic versus transesophageal echocardiographic guidance. J Am Soc Echocardiogr. 2017;30(6):533–40.

    Article  PubMed  Google Scholar 

  115. Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, Eggebrecht H, Rubino P, Michev I, Lange R, Anderson WN, Wendler O. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2010;122(1):62–9.

    Article  PubMed  Google Scholar 

  116. Shah P, Bajaj S, Shamoon F. Aortic dissection caused by percutaneous coronary intervention: 2 new case reports and detailed analysis of 86 previous cases. Tex Heart Inst J. 2016;43(1):52–60.

    Article  PubMed  PubMed Central  Google Scholar 

  117. Dunning DW, Kahn JK, Hawkins ET, O’Neill WW. Iatrogenic coronary artery dissections extending into and involving the aortic root. Catheter Cardiovasc Interv. 2000;51(4):387–93.

    Article  CAS  PubMed  Google Scholar 

  118. Puippe GD. [Complicated acute type B aortic dissection-what does endovascular therapy contribute?]. Radiologe. 2018;58(9):822–8.

    Article  CAS  PubMed  Google Scholar 

  119. Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP 3rd, Guyton RA, O’Gara PT, Ruiz CE, Skubas NJ, Sorajja P, Sundt TM 3rd, Thomas JD. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol. 2014;63(22):e57–185.

    Article  PubMed  Google Scholar 

  120. Doherty JU, Kort S, Mehran R, Schoenhagen P, Soman P. ACC/AATS/AHA/ASE/ASNC/HRS/SCAI/SCCT/SCMR/STS 2017 appropriate use criteria for multimodality imaging in valvular heart disease: a Report of the American College of Cardiology Appropriate Use Criteria Task Force, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. J Nucl Cardiol. 2017;24(6):2043–63.

    Article  PubMed  Google Scholar 

  121. Zoghbi WA, Adams D, Bonow RO, Enriquez-Sarano M, Foster E, Grayburn PA, Hahn RT, Han Y, Hung J, Lang RM, Little SH, Shah DJ, Shernan S, Thavendiranathan P, Thomas JD, Weissman NJ. Recommendations for noninvasive evaluation of native valvular regurgitation: a Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2017;30(4):303–71.

    Article  PubMed  Google Scholar 

  122. Mitchell C, Rahko PS, Blauwet LA, Canaday B, Finstuen JA, Foster MC, Horton K, Ogunyankin KO, Palma RA, Velazquez EJ. Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults: recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2019;32(1):1–64.

    Article  PubMed  Google Scholar 

  123. Hahn RT, Abraham T, Adams MS, Bruce CJ, Glas KE, Lang RM, Reeves ST, Shanewise JS, Siu SC, Stewart W, Picard MH. Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. Anesth Analg. 2014;118(1):21–68.

    Article  PubMed  Google Scholar 

  124. Zoghbi WA, Asch FM, Bruce C, Gillam LD, Grayburn PA, Hahn RT, Inglessis I, Islam AM, Lerakis S, Little SH, Siegel RJ, Skubas N, Slesnick TC, Stewart WJ, Thavendiranathan P, Weissman NJ, Yasukochi S, Zimmerman KG. Guidelines for the evaluation of valvular regurgitation after percutaneous valve repair or replacement: a Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2019;32(4):431–75.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Michel Zuber .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Ho, E. et al. (2020). Assessment and Follow-Up. In: Maisano, F., Kaufmann, P., Alkadhi, H., Zuber, M., Pozzoli, A., Ho, E. (eds) Multimodality Imaging for Cardiac Valvular Interventions, Volume 1 Aortic Valve. Springer, Cham. https://doi.org/10.1007/978-3-030-27584-6_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-27584-6_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-27583-9

  • Online ISBN: 978-3-030-27584-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics