Abstract

Preoperative Preparation

  1. 1.

    Place multiple large-bore intravenous lines.

  2. 2.

    Utilize double-lumen endotracheal tube.

  3. 3.

    Place right radial arterial monitoring line.

  4. 4.

    Consider PA catheter.

  5. 5.

    Ensure all IV fluids are warmed.

  6. 6.

    Ensure generous blood supply available.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 54.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 69.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Suggested Reading

  • Acher C, Acher CW, Marks E, Wynn M. Intraoperative neuroprotective interventions prevent spinal cord ischemia and injury in thoracic endovascular aortic repair. J Vasc Surg. 2016;63(6):1458–65.

    Article  Google Scholar 

  • Cambria RP, Crawford RS, Cho JS, Bavaria J, Farber M, Lee WA, Ramaiah V, Kwolek CJ, GORE TAG Investigators. A multicenter clinical trial of endovascular stent graft repair of acute catastrophes of the descending thoracic aorta. J Vasc Surg. 2009;50(6):1255–64.e1–4.

    Article  Google Scholar 

  • Hoffer EK, Karmy-Jones R, Bloch RD, Meissner MH, Borsa JJ, Nicholls SC, et al. Treatment of acute thoracic aortic injury with commercially available abdominal aortic stent-grafts. J Vasc Interv Radiol. 2002;13(10):1037–41.

    Article  Google Scholar 

  • Kasirajan K, Heffernan D, Langsfeld M. Acute thoracic aortic trauma: a comparison of endoluminal stent grafts with open repair and nonoperative management. Ann Vasc Surg. 2003;17(6):589–95.

    Article  Google Scholar 

  • Schumacher H, Böckler D, von Tengg-Kobligk H, Allenberg JR. Acute traumatic aortic tear: open versus stent-graft repair. Semin Vasc Surg. 2006;19(1):48–59.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Rodriguez, A., Elliott, D.C. (2020). Open Repair of Traumatic Thoracic Aortic Injury Without Shunt, and Using a Woven Dacron Graft. In: Ferrada, P., Ferrada, R. (eds) Atlas of Trauma. Springer, Cham. https://doi.org/10.1007/978-3-030-26871-8_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-26871-8_4

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-26870-1

  • Online ISBN: 978-3-030-26871-8

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics