Abstract
Measurement of arterial blood pressure (BP) by the brachial cuff sphygmomanometer has been a cornerstone of modern medicine, and notwithstanding its limitations of intermittent BP monitoring, the cuff sphygmomanometer has not been surpassed by any other noninvasive methodology. However, advances in sensor technology for arterial pulse detection have paved the way for the potential development of devices for cuffless measurement of BP, with the prospect of continuous monitoring. Just as the cuff sphygmomanometer could be considered as having provided a significant step in establishing elevated BP as a major factor of cardiovascular risk since the turn of the twentieth century, cuffless BP monitoring might be considered a disruptive technology for continuous BP monitoring in healthy individuals during daily living and could become an integral component of modern digital health platforms in the twenty-first century. This volume of the Handbook of Cuffless Blood Pressure Monitoring addresses the significant challenges faced by this methodology. The underlying physiology and hemodynamic principles involved in the generation of the arterial pressure pulse are complemented by the clinical relevance of the novel cuffless methodologies in relation to the conventional cuff sphygmomanometer. The underlying pressure dependency of arterial properties, which is at the base of the cuffless technique employing pulse transit measurement as a surrogate measure of BP, is addressed in association with instrumentation, measurement techniques, calibration procedures, device validation and regulatory requirements. This book provides a timely and comprehensive platform on how to approach the critical question of whether cuffless is the future of BP monitoring.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Marey E-J. Le vol des insectes étudié par la chronophotographie. La Nat. 1892;20(1):135–8.
Fischer JW. The diagnostic value of the sphygmomanometer in examinations for life insurance. JAMA. 1914;63:3.
Mukkamala R, Hahn JO, Inan OT, Mestha LK, Kim CS, Töreyin H, Kyal S. Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice. IEEE Trans Biomed Eng. 2015;62:1879–901.
Shadwick RE. Mechanical design in arteries. J Exp Biol. 1999;202:3305–13.
Butlin M, Shirbani F, Barin E, Tan I, Spronck B, Avolio AP. Cuffless estimation of blood pressure: importance of variability in blood pressure dependence of arterial stiffness across individuals and measurement sites. IEEE Trans Biomed Eng. 2018;65:2377–83.
Ding X, Zhang Y, Tsang HK. Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation. Physiol Meas. 2016;37:227–37.
Khalid SG, Zhang J, Chen F, Zheng D. Blood pressure estimation using photoplethysmography only: comparison between different machine learning approaches. J Healthc Eng. 2018;2018:1548647.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Avolio, A., Shirbani, F., Tan, I., Butlin, M. (2019). Cuffless Blood Pressure Monitoring and the Advent of a New Era in Medicine and Society. In: Solà, J., Delgado-Gonzalo, R. (eds) The Handbook of Cuffless Blood Pressure Monitoring. Springer, Cham. https://doi.org/10.1007/978-3-030-24701-0_1
Download citation
DOI: https://doi.org/10.1007/978-3-030-24701-0_1
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-24700-3
Online ISBN: 978-3-030-24701-0
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)