Abstract

The chapter includes protection power systems based on the IEC 61850 protocol for data communication systems between substations. The IEC 61850 is adequate for real time communication between IED based on GOOSE messages. The chapter includes the case study from the Romanian power systems: implementation of protection and remote control system in transformer station 110 kV/20 kV Laminor, using IEC 61850.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   139.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   179.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   179.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. H. Leon, C. Montez, M.R. Stemmer, F. Vasques, Simulation models for IEC 61850 communication in electrical substations using GOOSE and SMV time-critical messages, in IEEE World Conference on Factory Communication Systems (WFCS), May 2016

    Google Scholar 

  2. http://www02.abb.com/global/sgabb/sgabb005.nsf/bf177942f19f4a98c1257148003b7a0a/e81bb489e5ae0b68482574d70020bf42/$FILE/B5_G2_Enhanced+protection+functionality+with+IEC+61850+and+GOOSE.pdf. Accessed 2018

  3. MiCOM P139 Feeder Management and Bay Control, SW Version-651. Manual (global file) P139/EN M/R-21-A, 2014. Accessed 2018; B. Kasztenny, N. Fischer, Advanced protection, automation, and control functions. Schweitzer Engineering Laboratories, Inc., in 1st Annual Protection, Automation and Control World Conference, June 2010

    Google Scholar 

  4. MiCOM P139 Feeder Management and Bay Control, SW Version- 651. Manual (global file) P139/EN M/R-21-A (2014)

    Google Scholar 

  5. M. Vadiati, M. Abbas Ghorbani, A.R. Ebrahimi, M. Arshia, Future trends of substation automation system by applying IEC 61850, in 43rd International Universities Power Engineering Conference (2008)

    Google Scholar 

  6. U-Series Three-Phase Recloser/W-Series Single-Phase Recloser Medium Voltage Distribution. Whitepaper (08/2017), http://www.ariaatlas.org/userfiles/files/product/179/ADVC_U_&_W_Series_Whitepaper.pdf. Accessed 2018

  7. https://www.schneider-electric.com/en/product-range-presentation/61035-easergy-studio/. Accessed 2018

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marian Gaiceanu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Gaiceanu, M., Arama, I.N. (2020). IEC 61850 Based Protection Systems. In: Mahdavi Tabatabaei, N., Kabalci, E., Bizon, N. (eds) Microgrid Architectures, Control and Protection Methods. Power Systems. Springer, Cham. https://doi.org/10.1007/978-3-030-23723-3_29

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-23723-3_29

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-23722-6

  • Online ISBN: 978-3-030-23723-3

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics