Skip to main content

High-Resolution Ex Vivo Microstructural MRI After Restoring Ventricular Geometry via 3D Printing

  • Conference paper
  • First Online:
Functional Imaging and Modeling of the Heart (FIMH 2019)

Abstract

Computational modeling of the heart requires accurately incorporating both gross anatomical detail and local microstructural information. Together, these provide the necessary data to build 3D meshes for simulation of cardiac mechanics and electrophysiology. Recent MRI advances make it possible to measure detailed heart motion in vivo, but in vivo microstructural imaging of the heart remains challenging. Consequently, the most detailed measurements of microstructural organization and microanatomical infarct details are obtained ex vivo. The objective of this work was to develop and evaluate a new method for restoring ex vivo ventricular geometry to match the in vivo configuration. This approach aids the integration of high-resolution ex vivo microstructural information with in vivo motion measurements. The method uses in vivo cine imaging to generate surface meshes, then creates a 3D printed left ventricular (LV) blood pool cast and a pericardial mold to restore the ex vivo cardiac geometry to a mid-diastasis reference configuration. The method was evaluated in healthy (N = 7) and infarcted (N = 3) swine. Dice similarity coefficients were calculated between in vivo and ex vivo images for the LV cavity (\(0.93\pm 0.01\)), right ventricle (RV) cavity (\(0.80\pm 0.05\)), and the myocardium (\(0.72\pm 0.04\)). The \(R^2\) coefficient between in vivo and ex vivo LV and RV cavity volumes were 0.95 and 0.91, respectively. These results suggest that this method adequately restores ex vivo geometry to match in vivo geometry. This approach permits a more precise incorporation of high-resolution ex vivo anatomical and microstructural data into computational models that use in vivo data for simulation of cardiac mechanics and electrophysiology.

This work was supported by NIH/NHLBI K25-HL135408 and R01-HL131823. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 59.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 79.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Aliotta, E., Wu, H.H., Ennis, D.B.: Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted MRI. Magn. Reson. Med. 77(2), 717–729 (2017)

    Article  Google Scholar 

  2. Bayer, J.D., Blake, R.C., Plank, G., Trayanova, N.A.: A novel rule-based algorithm for assigning myocardial fiber orientation to computational heart models. Ann. Biomed. Eng. 40(10), 2243–2254 (2012)

    Article  Google Scholar 

  3. Ennis, D.B., Kindlmann, G.: Orthogonal tensor invariants and the analysis of diffusion tensor magnetic resonance images. Magn. Reson. Med. Off. J. Int. Soc. Magn. Reson. Med. 55(1), 136–146 (2006)

    Article  Google Scholar 

  4. Kellman, P., Arai, A.E., McVeigh, E.R., Aletras, A.H.: Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement. Magn. Reson. Med. Off. J. Int. Soc. Magn. Reson. Med. 47(2), 372–383 (2002)

    Article  Google Scholar 

  5. Kung, G.L., et al.: Microstructural infarct border zone remodeling in the post-infarct swine heart measured by diffusion tensor MRI. Front. Physiol. 9 (2018)

    Google Scholar 

  6. Nielles-Vallespin, S., et al.: Assessment of myocardial microstructural dynamics by in vivo diffusion tensor cardiac magnetic resonance. J. Am. Coll. Cardiol. 69(6), 661–676 (2017)

    Article  Google Scholar 

  7. Ponnaluri, A.V., et al.: Electrophysiology of heart failure using a rabbit model: from the failing myocyte to ventricular fibrillation. PLoS Comput. Biol. 12(6), e1004968 (2016)

    Article  Google Scholar 

  8. Sack, K., et al.: Effect of intra-myocardial Algisyl-LVR\(^{{{TM}}}\) injectates on fibre structure in porcine heart failure. J. Mech. Behav. Biomed. Mater. 87, 172–179 (2018)

    Article  Google Scholar 

  9. Stoeck, C.T., et al.: Dual-phase cardiac diffusion tensor imaging with strain correction. PLoS One 9(9), e107159 (2014)

    Article  Google Scholar 

  10. Teh, I., et al.: Resolving fine cardiac structures in rats with high-resolution diffusion tensor imaging. Sci. Rep. 6, 30573 (2016)

    Article  Google Scholar 

  11. Verzhbinsky, I.A., Magrath, P., Aliotta, E., Ennis, D.B., Perotti, L.E.: Time resolved displacement-based registration of in vivo cDTI cardiomyocyte orientations. In: 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018), pp. 474–478. IEEE (2018)

    Google Scholar 

  12. Wang, V.Y., Lam, H., Ennis, D.B., Cowan, B.R., Young, A.A., Nash, M.P.: Modelling passive diastolic mechanics with quantitative MRI of cardiac structure and function. Med. Image Anal. 13(5), 773–784 (2009)

    Article  Google Scholar 

  13. Wehrl, H.F., et al.: Assessment of murine brain tissue shrinkage caused by different histological fixatives using magnetic resonance and computed tomography imaging. Histol. Histopathol. 30(5), 601–613 (2015)

    Google Scholar 

  14. Wolf, I., et al.: The medical imaging interaction toolkit. Med. Image Anal. 9(6), 594–604 (2005)

    Article  Google Scholar 

  15. Wu, H.H., et al.: A system using patient-specific 3D-printed molds to spatially align in vivo MRI with ex vivo MRI and whole-mount histopathology for prostate cancer research. J. Magn. Reson. Imaging 49(1), 270–279 (2019)

    Article  Google Scholar 

  16. Zhong, X., Spottiswoode, B.S., Meyer, C.H., Kramer, C.M., Epstein, F.H.: Imaging three-dimensional myocardial mechanics using navigator-gated volumetric spiral cine DENSE MRI. Magn. Reson. Med. 64(4), 1089–1097 (2010)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Daniel B. Ennis .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Cork, T.E., Perotti, L.E., Verzhbinsky, I.A., Loecher, M., Ennis, D.B. (2019). High-Resolution Ex Vivo Microstructural MRI After Restoring Ventricular Geometry via 3D Printing. In: Coudière, Y., Ozenne, V., Vigmond, E., Zemzemi, N. (eds) Functional Imaging and Modeling of the Heart. FIMH 2019. Lecture Notes in Computer Science(), vol 11504. Springer, Cham. https://doi.org/10.1007/978-3-030-21949-9_20

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-21949-9_20

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-21948-2

  • Online ISBN: 978-3-030-21949-9

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics