Abstract
The lightning shielding performance of shield wires in the fully composite pylon has been verified by experimental methods in this chapter. In order to verify the conclusion obtained by electro-geometric model (EGM) analysis in Chap. 6, a scale model test has been performed. Direct lightning strikes to phase conductors are simulated by electrical discharges to scale phase conductors with fast-front and slow-front impulses in the high voltage lab. Shielding failure rate (SFR) is obtained by interpreting the ratio of number of discharges to scale phase conductors to the total number of discharges. Additionally, the maximum shielding failure current is obtained by scale model tests. Comparing results developed by theoretical method—electro-geometric model (EGM) and experimental method-scale model test, it proves that these two methods verify each other and support each other’s application to the lightning shielding investigation in the innovative fully composite pylon. A conclusion can be drawn that, as regards to protection from direct lightning strikes, shield wires in the fully composite pylon can prove acceptable lightning protection for overhead lines.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
I. S. 1410, Guide for improving the lightning performance of electric power overhead distribution lines, Std., Jan 2011
S. Taniguchi, S. Okabe, T. Takahashi, T. Shindo, Discharge characteristics of 5 m long air gap under foggy conditions with lightning shielding of transmission line. IEEE Trans. Dielectr. Electr. Insul. 15(4), 1031–1037 (2008)
J. Takami, S. Okabe, Characteristics of direct lightning strokes to phase conductors of UHV transmission lines. IEEE Trans. Power Deliv. 22(1), 537–546 (2007)
Y. An, Y. Hu, X. Wen, Z. Jiang, L. Lan, Review of experimental study on lightning shielding performance of transmission line. High Volt. Appar. 52(7), 1–9 (2016). (in Chinese)
Q. Wang, T. Jahangiri, C.L. Bak, F.F. da Silva, H. Skouboe, Investigation on shielding failure of a novel 400 kV double-circuit composite tower. IEEE Trans. Power Deliv. 33(2), 752–760 (2018)
A.R. Hileman, Insulation Coordination for Power Systems. (Taylor & Francis, 1999). Chapter 6: The lightning flashes
S. Taniguchi, S. Okabe, A contribution to the investigation of the shielding effect of transmission line conductors to lightning strikes. IEEE Trans. Dielectr. Electr. Insul. 15(3), 710–720 (2008). Jun
H. He, J. He, D. Zhang, L. Ding, Z. Jiang, C. Wang, H. Ye, Experimental study on lightning shielding performance of +/\(-\) 500 kV transmission lines, in Conference on Asia-Pacific Power and Energy Engineering, Wuhan, China, Mar 2009, pp. 1–7
G. Qian, X. Wang, Y. Wang, The lightning shielding simulation theory and test technology. High Volt. Eng. 24(2), 26–31 (1998). (in Chinese)
W. Chen, H. He, G. Qian, J. Chen, Review of the lightning shielding against direct lightning strokes based on laboratory long air gap discharges. Proc. Chin. Soc. Electr. Eng. 32(10), 1–12 (2012)
C. W. C4-26, Evaluation of lightning shielding analysis methods for EHV and UHV DC and AC transmission lines, CIGRE Technical Brochure, Oct 2017
Z. An, L. Lan, X. Wen, Y. Wang, Impacting factors of large sized model test for lightning shielding performance of UHV transmission lines. Power Syst. Technol. 38(5) (2014)
T. Jahangiri, C.L. Bak, F.F. Silva, B. Endahl, Determination of minimum air clearances for a 420 kV novel unibody composite cross-arm, in 50th International Universities Power Engineering Conference (UPEC), Stokeontrent, UK, Sep 2015, pp. 1–6
Q. Wang, C.L. Bak, F.F. Silva, H. Skouboe, Scale model test on a novel 400 kV double-circuit composite pylon, in International Conference on Power System Transients Seoul, South Korea, Jun 2017
T. Jahangiri, C.L. Bak, F.F. Silva, B. Endahl, Assessment of lightning shielding performance of a 400 kV double-circuit fully composite transmission line pylon, in Cigré Session, Paris, France: CIGRE, Aug 2016
M.A. Uman, The Lightning Discharge. (Courier Corporation, 2001)
A.R. Hileman, Insulation Coordination for Power Systems. (Taylor & Francis, 1999). Chapter 6: The lightning flashes, p. 205
M.S. Banjanin, M.S. Savić, Z.M. Stojković, Lightning protection of overhead transmission lines using external ground wires. Electr. Power Syst. Res. 127, 206–212 (2015)
T. Disyadej, S. Mallick, S. Grzybowski, Laboratory study for estimating the number of lightning flashes to transmission lines, in North American Power Symposium (NAPS), Starkville, USA, Oct 2009, pp. 1–4
K. Miyake, I. Kishizima, T. Suzuki, Study on experimental simulation of lightning strokes. IEEE Power Eng. Rev. 4, 41–42 (1981)
Y. Wang, Y. An, E. Shenglong, X. Wen, Factors effect on discharge path to scaled UHV transmission lines, in International Conference on Lightning Protection, Oct 2014 (IEEE, Shanghai, China, 2014), pp. 493–497
I.W. Group, et al., A simplified method for estimating lightning performance of transmission lines, IEEE Trans. Power App. Syst.104(4), 919–932 (1985)
C. W. 33-01, Guide to procedures for estimating the lightning performance of transmission lines. CIGRE (1991)
Q. Wang, T. Jahangiri, C.L. Bak, F.F. da Silva, Experimental evaluation of shielding angles effects on lightning performance in a 400 kV AC double-circuit composite pylon, in CIGRÉ Symposium, Dublin, Ireland, May 2017
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Jahangiri, T., Wang, Q., da Silva, F.F., Leth Bak, C. (2020). Lightning Shielding Failure Investigation by High Voltage Experiments. In: Electrical Design of a 400 kV Composite Tower. Lecture Notes in Electrical Engineering, vol 557. Springer, Cham. https://doi.org/10.1007/978-3-030-17843-7_7
Download citation
DOI: https://doi.org/10.1007/978-3-030-17843-7_7
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-17842-0
Online ISBN: 978-3-030-17843-7
eBook Packages: EngineeringEngineering (R0)