Abstract
Digital dentistry has evolved very rapidly in recent years. Areas of digital fixed and implant dentistry have shown a wide range of improvement from examinations to production of prostheses. Digital applications in removable prosthodontics have been initiated as two-visit techniques during the late 2000s by two commercially available companies. However, further improvements and increased number of applications in digital removable complete denture (DRCD) have been done lately since several new companies have announced new developments in this field. In this chapter, you will find background information of the evolution of DRCD with a literature review, comparison of conventional and digital workflows of denture fabrication, current concepts and different fabrication methods of DRCD, and advantages and limitations of DRCD. Wax rim impression and replication DRCD techniques are explained and illustrated in a step-by-step fashion.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Goyal G. History of impressions, impression materials and impression techniques in complete dentures. J Adv Med Dent Sci. 2014;2(2):116–9.
Khindria SK, Mittal S, Sukhija U. Evolution of denture base materials. J Indian Prosthodont Soc. 2009;9:64–9.
Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont. 1994;7:17–21.
Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil. 1997;24:540–8.
Busch M, Kordass B. Concept and development of a computerized positioning of prosthetic teeth for complete dentures. Int J Comput Dent. 2006;9:113–20.
Sun Y, Lü P, Wang Y. Study on CAD and RP for removable complete denture. Comput Methods Prog Biomed. 2009;93:266–72.
Inokoshi M, Kanazawa M, Minakuchi S. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J. 2012;31:40–6.
Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 2011;30:93–6.
Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent. 2012;107:34–46.
Masri R, Driscoll CF. Clinical applications of digital dental technology. New York: John Wiley & Son Inc.; 2015. p. 107–38.
Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent. 2014;111:351–5.
Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 2013;41:407–16.
Bidra AS, Farrell K, Burnham D, Dhingra A, Taylor TD, Kuo CL. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: clinical and patient-centered outcomes. J Prosthet Dent. 2016;115:578–86.
Peng L, Chen L, Harris BT, Morton D, Lin WS. Managing complications resulting from limited prosthetic space with a monolithic, multichromatic CAD-CAM implant-retained overdenture: a dental technique. J Prosthet Dent. 2017;118(6):712–6.
Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent. 2016;64:23–8.
Saponaro PC, Yilmaz B, Heshmati RH, McGlumphy EA. Clinical performance of CAD-CAM-fabricated complete dentures: a cross-sectional study. J Prosthet Dent. 2016;116:431–5.
Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent. 2015;114:818–25.
Fernandez MA, Arthur Nimmo A, Behar-Horenstein LS. Digital denture fabrication in pre- and postdoctoral education: a survey of U.S. dental schools. J Prosthodont. 2016;25:83–90.
Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, Dumfahrt H. Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Invest. 2017;21:1697–705.
Al Helal A, Al Rumaih HS, Kattadiyil MT, Baba NZ, Charles J, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: a clinical study. J Prosthet Dent. 2017;117:233–8.
Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2018;119(1):108–15.
Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109:361–6.
Kattadiyil MT, Al Helal A. An update on computer-engineered complete dentures: a systematic review on clinical outcomes. J Prosthet Dent. 2017;117(4):478–85.
Schwindling FS, Stober T. A comparison of two digital techniques for the fabrication of complete removable dental prostheses: a pilot clinical study. J Prosthet Dent. 2016;116:756–63.
Wimmer T, Gallus K, Eichberger M, Stawarczyk B. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent. 2016;115:541–6.
Schweiger J, Güth JF, Edelhoff D, Stumbaum J. Virtual evaluation for CAD-CAM-fabricated complete dentures. J Prosthet Dent. 2017;117:28–33.
Yilmaz B, Azak AN, Alp G, Eksi H. Use of CAD-CAM technology for the fabrication of complete dentures: An alternative technique. J Prosthet Dent. 2017;118:140–3.
Ohkubo C, Shimpo H, Tokue A, Park EJ, Kim TH. Complete denture fabrication using piezography and CAD-CAM: a clinical report. J Prosthet Dent. 2018;119:334–8.
Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent. 2013;109(2):121–8.
Patzelt SB, Vonau S, Stampf S, Att W. Assessing the feasibility and accuracy of digitizing edentulous jaws. J Am Dent Assoc. 2013;144:914–20.
Gan N, Xiong Y, Jiao T. Accuracy of intraoral digital impressions for whole upper jaws, including full dentitions and palatal soft tissues. PLoS One. 2016; https://doi.org/10.1371/journal.pone.0158800.
Fang JH, An X, Jeong SM, Choi BH. Digital immediate denture: a clinical report. J Prosthet Dent. 2017; https://doi.org/10.1016/j.prosdent.2017.06.004. pii: S0022-3913(17)30427-4. 2017 Sept 16 [Epub ahead of print].
Lee JH. Improved digital impressions of edentulous areas. J Prosthet Dent. 2017;117(3):448–9.
Goodacre BJ, Goodacre CJ. Using intraoral scanning to fabricate complete dentures: first experiences. Int J Prosthodont. 2018;31(2):166–70. https://doi.org/10.11607/ijp.5624.
Aguirre BC. Flexural strength of denture base acrylic resins processed by conventional and CAD?CAM methods. Master thesis, Texas A&M University, May 2017.
Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2016;116:249–56.
Katase H, Kanazawa M, Inokoshi M, Minakuchi S. Face simulation system for complete dentures by applying rapid prototyping. J Prosthet Dent. 2013;109:353–60.
de Mendonça AF, de Mendonça MF, White GS, Sara G, Littlefair D. Total CAD/CAM supported method for manufacturing removable complete dentures. Case Rep Dent. 2016;2016:1259581. https://doi.org/10.1155/2016/1259581.
Neumeier TT, Neumeier H. Digital immediate dentures treatment: a clinical report of two patients. J Prosthet Dent. 2016;116:314–9.
Alsayed HD, Alqahtani NM, Alzayer YM, Morton D, Levon JA, Baba NZ. Prosthodontic rehabilitation with monolithic, multichromatic CAD-CAM complete overdentures in an adolescent patient with ectodermal dysplasia: a clinical report. J Prosthet Dent. 2017; https://doi.org/10.1016/j.prosdent.2017.08.010. pii: S0022-3913(17)30568-1. 2017 Nov 15 [Epub ahead of print].
Bidra AS. The 2-visit CAD-CAM implant-retained overdenture: a clinical report. J Oral Implantol. 2014;40:722–8.
Lozada JL, Garbacea A, Goodacre CJ, Kattadiyil MT. Use of a digitally planned and fabricated mandibular complete denture for easy conversion to an immediately loaded provisional fixed complete denture. Part 1. Planning and surgical phase. Int J Prosthodont. 2014;27:417–21.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Hirayama, H. (2019). Digital Removable Complete Denture (DRCD). In: Tamimi, F., Hirayama, H. (eds) Digital Restorative Dentistry . Springer, Cham. https://doi.org/10.1007/978-3-030-15974-0_6
Download citation
DOI: https://doi.org/10.1007/978-3-030-15974-0_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-15973-3
Online ISBN: 978-3-030-15974-0
eBook Packages: MedicineMedicine (R0)